ABAP Select data from SAP table /SCWM/TMFSPLC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/TMFSPLC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/TMFSPLC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/TMFSPLC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/TMFSPLC TYPE STANDARD TABLE OF /SCWM/TMFSPLC,
      WA_/SCWM/TMFSPLC TYPE /SCWM/TMFSPLC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/TMFSPLC> TYPE /SCWM/TMFSPLC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/TMFSPLC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/TMFSPLC
  INTO TABLE IT_/SCWM/TMFSPLC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/TMFSPLC
*  INTO TABLE @DATA(IT_/SCWM/TMFSPLC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/TMFSPLC INDEX 1 INTO DATA(WA_/SCWM/TMFSPLC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/TMFSPLC ASSIGNING </SCWM/TMFSPLC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/TMFSPLC>-MANDT = 1.
</SCWM/TMFSPLC>-LGNUM = 1.
</SCWM/TMFSPLC>-PLC = 1.
</SCWM/TMFSPLC>-TELECORE = 1.
</SCWM/TMFSPLC>-PROCTYPE = 1.
ENDLOOP.

LOOP AT IT_/SCWM/TMFSPLC INTO WA_/SCWM/TMFSPLC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/TMFSPLC-PROCTYPE_ERR, sy-vline,
WA_/SCWM/TMFSPLC-CL_MODE, sy-vline,
WA_/SCWM/TMFSPLC-RFCDST, sy-vline,
WA_/SCWM/TMFSPLC-FM_SEND, sy-vline,
WA_/SCWM/TMFSPLC-FM_START, sy-vline,
WA_/SCWM/TMFSPLC-FM_STOP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/TMFSPLC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/TMFSPLC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/TMFSPLC INTO WA_/SCWM/TMFSPLC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/TMFSPLC_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
PLC TYPE STRING,
TELECORE TYPE STRING,
PROCTYPE TYPE STRING,
PROCTYPE_ERR TYPE STRING,
CL_MODE TYPE STRING,
RFCDST TYPE STRING,
FM_SEND TYPE STRING,
FM_START TYPE STRING,
FM_STOP TYPE STRING,
FM_HEALTH TYPE STRING,
LOGGING TYPE STRING,
EXCCODE TYPE STRING,
EWM_ID TYPE STRING,
MAPOBJ TYPE STRING,
PLCIFTYPE TYPE STRING,
PROCTYPE_ATF TYPE STRING,
PLC_MODE TYPE STRING,
PROCTYPE_STOCK_TRANS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/TMFSPLC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/TMFSPLC_STR-MANDT sy-vline
WA_/SCWM/TMFSPLC_STR-LGNUM sy-vline
WA_/SCWM/TMFSPLC_STR-PLC sy-vline
WA_/SCWM/TMFSPLC_STR-TELECORE sy-vline
WA_/SCWM/TMFSPLC_STR-PROCTYPE sy-vline
WA_/SCWM/TMFSPLC_STR-PROCTYPE_ERR sy-vline
WA_/SCWM/TMFSPLC_STR-CL_MODE sy-vline
WA_/SCWM/TMFSPLC_STR-RFCDST sy-vline
WA_/SCWM/TMFSPLC_STR-FM_SEND sy-vline
WA_/SCWM/TMFSPLC_STR-FM_START sy-vline
WA_/SCWM/TMFSPLC_STR-FM_STOP sy-vline
WA_/SCWM/TMFSPLC_STR-FM_HEALTH sy-vline
WA_/SCWM/TMFSPLC_STR-LOGGING sy-vline
WA_/SCWM/TMFSPLC_STR-EXCCODE sy-vline
WA_/SCWM/TMFSPLC_STR-EWM_ID sy-vline
WA_/SCWM/TMFSPLC_STR-MAPOBJ sy-vline
WA_/SCWM/TMFSPLC_STR-PLCIFTYPE sy-vline
WA_/SCWM/TMFSPLC_STR-PROCTYPE_ATF sy-vline
WA_/SCWM/TMFSPLC_STR-PLC_MODE sy-vline
WA_/SCWM/TMFSPLC_STR-PROCTYPE_STOCK_TRANS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.