ABAP Select data from SAP table /SCWM/S_WIP_SR_VEH_HDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_WIP_SR_VEH_HDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_WIP_SR_VEH_HDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_WIP_SR_VEH_HDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_WIP_SR_VEH_HDR TYPE STANDARD TABLE OF /SCWM/S_WIP_SR_VEH_HDR,
      WA_/SCWM/S_WIP_SR_VEH_HDR TYPE /SCWM/S_WIP_SR_VEH_HDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_WIP_SR_VEH_HDR> TYPE /SCWM/S_WIP_SR_VEH_HDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_WIP_SR_VEH_HDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_WIP_SR_VEH_HDR
  INTO TABLE IT_/SCWM/S_WIP_SR_VEH_HDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_WIP_SR_VEH_HDR
*  INTO TABLE @DATA(IT_/SCWM/S_WIP_SR_VEH_HDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_WIP_SR_VEH_HDR INDEX 1 INTO DATA(WA_/SCWM/S_WIP_SR_VEH_HDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_WIP_SR_VEH_HDR ASSIGNING </SCWM/S_WIP_SR_VEH_HDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_WIP_SR_VEH_HDR>-VEH_NUM = 1.
</SCWM/S_WIP_SR_VEH_HDR>-VEH_SR_ACT_NUM = 1.
</SCWM/S_WIP_SR_VEH_HDR>-VEH_NUM_EXT = 1.
</SCWM/S_WIP_SR_VEH_HDR>-SR_ACT_STATE_TXT = 1.
</SCWM/S_WIP_SR_VEH_HDR>-START_PLAN_TSTFR_D = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_WIP_SR_VEH_HDR INTO WA_/SCWM/S_WIP_SR_VEH_HDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_WIP_SR_VEH_HDR-START_PLAN_TSTFR_T, sy-vline,
WA_/SCWM/S_WIP_SR_VEH_HDR-START_PLAN_TSTTO_D, sy-vline,
WA_/SCWM/S_WIP_SR_VEH_HDR-START_PLAN_TSTTO_T, sy-vline,
WA_/SCWM/S_WIP_SR_VEH_HDR-END_PLAN_TSTFR_D, sy-vline,
WA_/SCWM/S_WIP_SR_VEH_HDR-END_PLAN_TSTFR_T, sy-vline,
WA_/SCWM/S_WIP_SR_VEH_HDR-END_PLAN_TSTTO_D, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_WIP_SR_VEH_HDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_WIP_SR_VEH_HDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_WIP_SR_VEH_HDR INTO WA_/SCWM/S_WIP_SR_VEH_HDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VEH_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field VEH_SR_ACT_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_SR_ACT_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_SR_ACT_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSP_CURR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-TSP_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-TSP_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field DRIVER_LGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-DRIVER_LGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-DRIVER_LGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FRD_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-FRD_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-FRD_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_VOLUME_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_VOLUME_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_VOLUME_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_L CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_L IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_L.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOAD_UOM_LWH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VEH_WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-VEH_WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPL_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_SR_VEH_HDR-TRANSPL_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_SR_VEH_HDR-TRANSPL_LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_WIP_SR_VEH_HDR_STR,
VEH_NUM TYPE STRING,
VEH_SR_ACT_NUM TYPE STRING,
VEH_NUM_EXT TYPE STRING,
SR_ACT_STATE_TXT TYPE STRING,
START_PLAN_TSTFR_D TYPE STRING,
START_PLAN_TSTFR_T TYPE STRING,
START_PLAN_TSTTO_D TYPE STRING,
START_PLAN_TSTTO_T TYPE STRING,
END_PLAN_TSTFR_D TYPE STRING,
END_PLAN_TSTFR_T TYPE STRING,
END_PLAN_TSTTO_D TYPE STRING,
END_PLAN_TSTTO_T TYPE STRING,
START_ACTUAL_D TYPE STRING,
START_ACTUAL_T TYPE STRING,
END_ACTUAL_D TYPE STRING,
END_ACTUAL_T TYPE STRING,
PRIOP TYPE STRING,
TSP_CURR TYPE STRING,
TSP_CURR_TEXT TYPE STRING,
SCAC_CURR TYPE STRING,
MTR TYPE STRING,
DRIVER TYPE STRING,
DRIVER_CO TYPE STRING,
DRIVER_LGE TYPE STRING,
LIC_PLATE_COUNTRY TYPE STRING,
LIC_PLATE TYPE STRING,
MOT TYPE STRING,
FRD_NUM TYPE STRING,
LOAD_WEIGHT TYPE STRING,
LOAD_WEIGHT_UOM TYPE STRING,
LOAD_VOLUME TYPE STRING,
LOAD_VOLUME_UOM TYPE STRING,
LOAD_LENGTH TYPE STRING,
LOAD_UOM_L TYPE STRING,
LOAD_WIDTH TYPE STRING,
LOAD_UOM_W TYPE STRING,
LOAD_HEIGHT TYPE STRING,
LOAD_UOM_LWH TYPE STRING,
VEH_WEIGHT TYPE STRING,
VEH_WEIGHT_UOM TYPE STRING,
COUNT_WHRS TYPE STRING,
DELAYED TYPE STRING,
COUNT_SHIPTO TYPE STRING,
COUNT_SUPPLIERS TYPE STRING,
/SCWM/VEH_HEAD TYPE STRING,
/SCWM/VEH_SR_ACT TYPE STRING,
TRANSPL_TYPE TYPE STRING,
LOGSYS TYPE STRING,
TRANSPL_LOGSYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_WIP_SR_VEH_HDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-VEH_NUM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-VEH_SR_ACT_NUM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-VEH_NUM_EXT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-SR_ACT_STATE_TXT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_PLAN_TSTFR_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_PLAN_TSTFR_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_PLAN_TSTTO_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_PLAN_TSTTO_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_PLAN_TSTFR_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_PLAN_TSTFR_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_PLAN_TSTTO_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_PLAN_TSTTO_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_ACTUAL_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-START_ACTUAL_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_ACTUAL_D sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-END_ACTUAL_T sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-PRIOP sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-TSP_CURR sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-TSP_CURR_TEXT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-SCAC_CURR sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-MTR sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-DRIVER sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-DRIVER_CO sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-DRIVER_LGE sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LIC_PLATE_COUNTRY sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LIC_PLATE sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-MOT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-FRD_NUM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_WEIGHT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_WEIGHT_UOM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_VOLUME sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_VOLUME_UOM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_LENGTH sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_UOM_L sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_WIDTH sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_UOM_W sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_HEIGHT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOAD_UOM_LWH sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-VEH_WEIGHT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-VEH_WEIGHT_UOM sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-COUNT_WHRS sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-DELAYED sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-COUNT_SHIPTO sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-COUNT_SUPPLIERS sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-/SCWM/VEH_HEAD sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-/SCWM/VEH_SR_ACT sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-TRANSPL_TYPE sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-LOGSYS sy-vline
WA_/SCWM/S_WIP_SR_VEH_HDR_STR-TRANSPL_LOGSYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.