ABAP Select data from SAP table /SCWM/S_WIP_LOAD_010 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_WIP_LOAD_010 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_WIP_LOAD_010. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_WIP_LOAD_010 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_WIP_LOAD_010 TYPE STANDARD TABLE OF /SCWM/S_WIP_LOAD_010,
      WA_/SCWM/S_WIP_LOAD_010 TYPE /SCWM/S_WIP_LOAD_010,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_WIP_LOAD_010> TYPE /SCWM/S_WIP_LOAD_010.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_WIP_LOAD_010.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_WIP_LOAD_010
  INTO TABLE IT_/SCWM/S_WIP_LOAD_010.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_WIP_LOAD_010
*  INTO TABLE @DATA(IT_/SCWM/S_WIP_LOAD_0102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_WIP_LOAD_010 INDEX 1 INTO DATA(WA_/SCWM/S_WIP_LOAD_0102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_WIP_LOAD_010 ASSIGNING </SCWM/S_WIP_LOAD_010>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_WIP_LOAD_010>-ROUTE = 1.
</SCWM/S_WIP_LOAD_010>-DEPDAT = 1.
</SCWM/S_WIP_LOAD_010>-DEPTIM = 1.
</SCWM/S_WIP_LOAD_010>-NO_WHR = 1.
</SCWM/S_WIP_LOAD_010>-CARRIER = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_WIP_LOAD_010 INTO WA_/SCWM/S_WIP_LOAD_010.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_WIP_LOAD_010-TU_NUM, sy-vline,
WA_/SCWM/S_WIP_LOAD_010-TU_NUM_EXT, sy-vline,
WA_/SCWM/S_WIP_LOAD_010-HU_LOADED, sy-vline,
WA_/SCWM/S_WIP_LOAD_010-HU_TO_LOAD, sy-vline,
WA_/SCWM/S_WIP_LOAD_010-HU_TO_PACK, sy-vline,
WA_/SCWM/S_WIP_LOAD_010-ITM_TO_PICK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_WIP_LOAD_010 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_WIP_LOAD_010 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_WIP_LOAD_010 INTO WA_/SCWM/S_WIP_LOAD_010. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CARRIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_LOAD_010-CARRIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_LOAD_010-CARRIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_LOAD_010-TU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_LOAD_010-TU_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_LOAD_010-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_LOAD_010-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WIP_LOAD_010-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WIP_LOAD_010-UNIT_V.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_WIP_LOAD_010_STR,
ROUTE TYPE STRING,
DEPDAT TYPE STRING,
DEPTIM TYPE STRING,
NO_WHR TYPE STRING,
CARRIER TYPE STRING,
TU_NUM TYPE STRING,
TU_NUM_EXT TYPE STRING,
HU_LOADED TYPE STRING,
HU_TO_LOAD TYPE STRING,
HU_TO_PACK TYPE STRING,
ITM_TO_PICK TYPE STRING,
ITM_TO_RLSE TYPE STRING,
WGT_TOTAL TYPE STRING,
UNIT_W TYPE STRING,
VOL_TOTAL TYPE STRING,
UNIT_V TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_WIP_LOAD_010_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-ROUTE sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-DEPDAT sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-DEPTIM sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-NO_WHR sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-CARRIER sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-TU_NUM sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-TU_NUM_EXT sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-HU_LOADED sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-HU_TO_LOAD sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-HU_TO_PACK sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-ITM_TO_PICK sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-ITM_TO_RLSE sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-WGT_TOTAL sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-UNIT_W sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-VOL_TOTAL sy-vline
WA_/SCWM/S_WIP_LOAD_010_STR-UNIT_V sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.