ABAP Select data from SAP table /SCWM/S_WB_STOCK_NONKEY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_WB_STOCK_NONKEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_WB_STOCK_NONKEY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_WB_STOCK_NONKEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_WB_STOCK_NONKEY TYPE STANDARD TABLE OF /SCWM/S_WB_STOCK_NONKEY,
      WA_/SCWM/S_WB_STOCK_NONKEY TYPE /SCWM/S_WB_STOCK_NONKEY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_WB_STOCK_NONKEY> TYPE /SCWM/S_WB_STOCK_NONKEY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_WB_STOCK_NONKEY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_WB_STOCK_NONKEY
  INTO TABLE IT_/SCWM/S_WB_STOCK_NONKEY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_WB_STOCK_NONKEY
*  INTO TABLE @DATA(IT_/SCWM/S_WB_STOCK_NONKEY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_WB_STOCK_NONKEY INDEX 1 INTO DATA(WA_/SCWM/S_WB_STOCK_NONKEY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_WB_STOCK_NONKEY ASSIGNING </SCWM/S_WB_STOCK_NONKEY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_WB_STOCK_NONKEY>-MATNR = 1.
</SCWM/S_WB_STOCK_NONKEY>-LPTYP = 1.
</SCWM/S_WB_STOCK_NONKEY>-LGTYP = 1.
</SCWM/S_WB_STOCK_NONKEY>-MATKL = 1.
</SCWM/S_WB_STOCK_NONKEY>-LGBER = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_WB_STOCK_NONKEY INTO WA_/SCWM/S_WB_STOCK_NONKEY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_WB_STOCK_NONKEY-INSPTYP, sy-vline,
WA_/SCWM/S_WB_STOCK_NONKEY-BIN_AT, sy-vline,
WA_/SCWM/S_WB_STOCK_NONKEY-VFDAT, sy-vline,
WA_/SCWM/S_WB_STOCK_NONKEY-WDATU, sy-vline,
WA_/SCWM/S_WB_STOCK_NONKEY-WEIGHT, sy-vline,
WA_/SCWM/S_WB_STOCK_NONKEY-UNIT_W, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_WB_STOCK_NONKEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_WB_STOCK_NONKEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_WB_STOCK_NONKEY INTO WA_/SCWM/S_WB_STOCK_NONKEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field TOP_HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-TOP_HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-TOP_HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TOP_UNIT_GW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-TOP_UNIT_GW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-TOP_UNIT_GW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TOP_UNIT_GV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-TOP_UNIT_GV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-TOP_UNIT_GV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field TOP_PMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_STOCK_NONKEY-TOP_PMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_STOCK_NONKEY-TOP_PMAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_WB_STOCK_NONKEY_STR,
MATNR TYPE STRING,
LPTYP TYPE STRING,
LGTYP TYPE STRING,
MATKL TYPE STRING,
LGBER TYPE STRING,
INSPTYP TYPE STRING,
BIN_AT TYPE STRING,
VFDAT TYPE STRING,
WDATU TYPE STRING,
WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
VOLUM TYPE STRING,
UNIT_V TYPE STRING,
CAPA TYPE STRING,
QUAN TYPE STRING,
MEINS TYPE STRING,
QUANA TYPE STRING,
ALTME TYPE STRING,
TOP_HUIDENT TYPE STRING,
TOP_LETYP TYPE STRING,
TOP_G_WEIGHT TYPE STRING,
TOP_N_WEIGHT TYPE STRING,
TOP_UNIT_GW TYPE STRING,
TOP_G_VOLUME TYPE STRING,
TOP_N_VOLUME TYPE STRING,
TOP_UNIT_GV TYPE STRING,
TOP_PMAT TYPE STRING,
TOP_PMTYP TYPE STRING,
TOP_PMCAT TYPE STRING,
EEW_STOCK TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_WB_STOCK_NONKEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-MATNR sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-LPTYP sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-LGTYP sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-MATKL sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-LGBER sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-INSPTYP sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-BIN_AT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-VFDAT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-WDATU sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-WEIGHT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-UNIT_W sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-VOLUM sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-UNIT_V sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-CAPA sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-QUAN sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-MEINS sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-QUANA sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-ALTME sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_HUIDENT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_LETYP sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_G_WEIGHT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_N_WEIGHT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_UNIT_GW sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_G_VOLUME sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_N_VOLUME sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_UNIT_GV sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_PMAT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_PMTYP sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-TOP_PMCAT sy-vline
WA_/SCWM/S_WB_STOCK_NONKEY_STR-EEW_STOCK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.