ABAP Select data from SAP table /SCWM/S_VAS_VIEW_ACT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_VAS_VIEW_ACT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_VAS_VIEW_ACT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_VAS_VIEW_ACT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_VAS_VIEW_ACT TYPE STANDARD TABLE OF /SCWM/S_VAS_VIEW_ACT,
      WA_/SCWM/S_VAS_VIEW_ACT TYPE /SCWM/S_VAS_VIEW_ACT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_VAS_VIEW_ACT> TYPE /SCWM/S_VAS_VIEW_ACT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_VAS_VIEW_ACT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_VAS_VIEW_ACT
  INTO TABLE IT_/SCWM/S_VAS_VIEW_ACT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_VAS_VIEW_ACT
*  INTO TABLE @DATA(IT_/SCWM/S_VAS_VIEW_ACT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_VAS_VIEW_ACT INDEX 1 INTO DATA(WA_/SCWM/S_VAS_VIEW_ACT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_VAS_VIEW_ACT ASSIGNING </SCWM/S_VAS_VIEW_ACT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_VAS_VIEW_ACT>-VAS_GUID = 1.
</SCWM/S_VAS_VIEW_ACT>-ACT_GUID = 1.
</SCWM/S_VAS_VIEW_ACT>-ACT_SEQ = 1.
</SCWM/S_VAS_VIEW_ACT>-PS_LEVEL = 1.
</SCWM/S_VAS_VIEW_ACT>-COMPLQTY = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_VAS_VIEW_ACT INTO WA_/SCWM/S_VAS_VIEW_ACT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_VAS_VIEW_ACT-UNIT, sy-vline,
WA_/SCWM/S_VAS_VIEW_ACT-STATUS, sy-vline,
WA_/SCWM/S_VAS_VIEW_ACT-STARTED_AT, sy-vline,
WA_/SCWM/S_VAS_VIEW_ACT-ENDED_AT, sy-vline,
WA_/SCWM/S_VAS_VIEW_ACT-CHGUSR, sy-vline,
WA_/SCWM/S_VAS_VIEW_ACT-DURATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_VAS_VIEW_ACT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_VAS_VIEW_ACT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_VAS_VIEW_ACT INTO WA_/SCWM/S_VAS_VIEW_ACT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PS_LEVEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-PS_LEVEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-PS_LEVEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field STARTED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-STARTED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-STARTED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field ENDED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-ENDED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-ENDED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field DURATION CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-DURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-DURATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLAN_QTY_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-PLAN_QTY_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-PLAN_QTY_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PLAN_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_VIEW_ACT-PLAN_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_VIEW_ACT-PLAN_MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_VAS_VIEW_ACT_STR,
VAS_GUID TYPE STRING,
ACT_GUID TYPE STRING,
ACT_SEQ TYPE STRING,
PS_LEVEL TYPE STRING,
COMPLQTY TYPE STRING,
UNIT TYPE STRING,
STATUS TYPE STRING,
STARTED_AT TYPE STRING,
ENDED_AT TYPE STRING,
CHGUSR TYPE STRING,
DURATION TYPE STRING,
WORKCENTER TYPE STRING,
COMPLQTY_UI TYPE STRING,
START_DATE TYPE STRING,
START_TIME TYPE STRING,
END_DATE TYPE STRING,
END_TIME TYPE STRING,
UI_PLAN_QTY TYPE STRING,
PLAN_QTY_UOM TYPE STRING,
PLAN_MATNR TYPE STRING,
EFFORT_CODE TYPE STRING,
LGNUM TYPE STRING,
PROCS_DESC TYPE STRING,
RDOCCAT TYPE STRING,
RDOCID TYPE STRING,
RITMID TYPE STRING,
MSG_POST TYPE STRING,
KIT_ACT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_VAS_VIEW_ACT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-VAS_GUID sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-ACT_GUID sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-ACT_SEQ sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-PS_LEVEL sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-COMPLQTY sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-UNIT sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-STATUS sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-STARTED_AT sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-ENDED_AT sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-CHGUSR sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-DURATION sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-WORKCENTER sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-COMPLQTY_UI sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-START_DATE sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-START_TIME sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-END_DATE sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-END_TIME sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-UI_PLAN_QTY sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-PLAN_QTY_UOM sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-PLAN_MATNR sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-EFFORT_CODE sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-LGNUM sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-PROCS_DESC sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-RDOCCAT sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-RDOCID sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-RITMID sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-MSG_POST sy-vline
WA_/SCWM/S_VAS_VIEW_ACT_STR-KIT_ACT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.