ABAP Select data from SAP table /SCWM/S_STOCK_UPLOAD_EXT_MC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_STOCK_UPLOAD_EXT_MC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_STOCK_UPLOAD_EXT_MC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_STOCK_UPLOAD_EXT_MC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_STOCK_UPLOAD_EXT_MC TYPE STANDARD TABLE OF /SCWM/S_STOCK_UPLOAD_EXT_MC,
      WA_/SCWM/S_STOCK_UPLOAD_EXT_MC TYPE /SCWM/S_STOCK_UPLOAD_EXT_MC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_STOCK_UPLOAD_EXT_MC> TYPE /SCWM/S_STOCK_UPLOAD_EXT_MC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_STOCK_UPLOAD_EXT_MC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_STOCK_UPLOAD_EXT_MC
  INTO TABLE IT_/SCWM/S_STOCK_UPLOAD_EXT_MC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_STOCK_UPLOAD_EXT_MC
*  INTO TABLE @DATA(IT_/SCWM/S_STOCK_UPLOAD_EXT_MC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_STOCK_UPLOAD_EXT_MC INDEX 1 INTO DATA(WA_/SCWM/S_STOCK_UPLOAD_EXT_MC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_STOCK_UPLOAD_EXT_MC ASSIGNING </SCWM/S_STOCK_UPLOAD_EXT_MC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_STOCK_UPLOAD_EXT_MC>-LGNUM = 1.
</SCWM/S_STOCK_UPLOAD_EXT_MC>-MANDT = 1.
</SCWM/S_STOCK_UPLOAD_EXT_MC>-POSTYPE = 1.
</SCWM/S_STOCK_UPLOAD_EXT_MC>-MATNR = 1.
</SCWM/S_STOCK_UPLOAD_EXT_MC>-OWNER = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_STOCK_UPLOAD_EXT_MC INTO WA_/SCWM/S_STOCK_UPLOAD_EXT_MC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-OWNER_ROLE, sy-vline,
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-BATCH, sy-vline,
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-CAT, sy-vline,
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-STOCK_DOCCAT, sy-vline,
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-STOCK_DOCNO, sy-vline,
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-STOCK_ITMNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_STOCK_UPLOAD_EXT_MC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_STOCK_UPLOAD_EXT_MC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_STOCK_UPLOAD_EXT_MC INTO WA_/SCWM/S_STOCK_UPLOAD_EXT_MC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-OWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-PMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-PMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field PARHUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-PARHUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-PARHUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field TOPHUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-TOPHUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-TOPHUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_GW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_GW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_TW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_TW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_GV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_GV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_TV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_TV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_LWH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_MAX_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_MAX_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-UNIT_MAX_LWH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SERID, internal->external for field SERID CALL FUNCTION 'CONVERSION_EXIT_SERID_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-SERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-SERID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_UPLOAD_EXT_MC-CWUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR,
LGNUM TYPE STRING,
MANDT TYPE STRING,
POSTYPE TYPE STRING,
MATNR TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
BATCH TYPE STRING,
CAT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
STOCK_USAGE TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
COO TYPE STRING,
QUAN TYPE STRING,
UNIT TYPE STRING,
HUTYP TYPE STRING,
LGPLA TYPE STRING,
GR_DATE TYPE STRING,
GR_TIME TYPE STRING,
VFDAT TYPE STRING,
PMAT TYPE STRING,
EXTNO TYPE STRING,
HUIDENT TYPE STRING,
PARHUIDENT TYPE STRING,
TOPHUIDENT TYPE STRING,
ROW TYPE STRING,
REFROW TYPE STRING,
G_WEIGHT TYPE STRING,
N_WEIGHT TYPE STRING,
UNIT_GW TYPE STRING,
T_WEIGHT TYPE STRING,
UNIT_TW TYPE STRING,
G_VOLUME TYPE STRING,
N_VOLUME TYPE STRING,
UNIT_GV TYPE STRING,
T_VOLUME TYPE STRING,
UNIT_TV TYPE STRING,
G_CAPA TYPE STRING,
N_CAPA TYPE STRING,
T_CAPA TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
UNIT_LWH TYPE STRING,
MAX_WEIGHT TYPE STRING,
TOLW TYPE STRING,
TARE_VAR TYPE STRING,
MAX_VOLUME TYPE STRING,
TOLV TYPE STRING,
CLOSED_PACKAGE TYPE STRING,
MAX_CAPA TYPE STRING,
MAX_LENGTH TYPE STRING,
MAX_WIDTH TYPE STRING,
MAX_HEIGHT TYPE STRING,
UNIT_MAX_LWH TYPE STRING,
SERID TYPE STRING,
CWQUAN TYPE STRING,
CWUNIT TYPE STRING,
CWEXACT TYPE STRING,
LOGPOS TYPE STRING,
UII TYPE STRING,
AMOUNT_LC TYPE STRING,
DUMMY_ISU TYPE STRING,
ZEUGN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-LGNUM sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MANDT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-POSTYPE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MATNR sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-OWNER sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-OWNER_ROLE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-BATCH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-CAT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-ENTITLED sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-COO sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-QUAN sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-HUTYP sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-LGPLA sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-GR_DATE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-GR_TIME sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-VFDAT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-PMAT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-EXTNO sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-HUIDENT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-PARHUIDENT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-TOPHUIDENT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-ROW sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-REFROW sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-G_WEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-N_WEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_GW sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-T_WEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_TW sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-G_VOLUME sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-N_VOLUME sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_GV sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-T_VOLUME sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_TV sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-G_CAPA sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-N_CAPA sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-T_CAPA sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-LENGTH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-WIDTH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-HEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_LWH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_WEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-TOLW sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-TARE_VAR sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_VOLUME sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-TOLV sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-CLOSED_PACKAGE sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_CAPA sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_LENGTH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_WIDTH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-MAX_HEIGHT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UNIT_MAX_LWH sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-SERID sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-CWQUAN sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-CWUNIT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-CWEXACT sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-LOGPOS sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-UII sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-AMOUNT_LC sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-DUMMY_ISU sy-vline
WA_/SCWM/S_STOCK_UPLOAD_EXT_MC_STR-ZEUGN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.