ABAP Select data from SAP table /SCWM/S_ROUTE_HD_MC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_ROUTE_HD_MC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_ROUTE_HD_MC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_ROUTE_HD_MC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_ROUTE_HD_MC TYPE STANDARD TABLE OF /SCWM/S_ROUTE_HD_MC,
      WA_/SCWM/S_ROUTE_HD_MC TYPE /SCWM/S_ROUTE_HD_MC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_ROUTE_HD_MC> TYPE /SCWM/S_ROUTE_HD_MC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_ROUTE_HD_MC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_ROUTE_HD_MC
  INTO TABLE IT_/SCWM/S_ROUTE_HD_MC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_ROUTE_HD_MC
*  INTO TABLE @DATA(IT_/SCWM/S_ROUTE_HD_MC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_ROUTE_HD_MC INDEX 1 INTO DATA(WA_/SCWM/S_ROUTE_HD_MC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_ROUTE_HD_MC ASSIGNING </SCWM/S_ROUTE_HD_MC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_ROUTE_HD_MC>-ID_ROUTE = 1.
</SCWM/S_ROUTE_HD_MC>-VAL_FROM = 1.
</SCWM/S_ROUTE_HD_MC>-VAL_TO = 1.
</SCWM/S_ROUTE_HD_MC>-LENGTH = 1.
</SCWM/S_ROUTE_HD_MC>-WIDTH = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_ROUTE_HD_MC INTO WA_/SCWM/S_ROUTE_HD_MC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_ROUTE_HD_MC-HEIGHT, sy-vline,
WA_/SCWM/S_ROUTE_HD_MC-LWH_UOM, sy-vline,
WA_/SCWM/S_ROUTE_HD_MC-WGT_MIN_SINGLE, sy-vline,
WA_/SCWM/S_ROUTE_HD_MC-WGT_MAX_SINGLE, sy-vline,
WA_/SCWM/S_ROUTE_HD_MC-WGT_MIN_TOTAL, sy-vline,
WA_/SCWM/S_ROUTE_HD_MC-WGT_MAX_TOTAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_ROUTE_HD_MC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_ROUTE_HD_MC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_ROUTE_HD_MC INTO WA_/SCWM/S_ROUTE_HD_MC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field VAL_FROM CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_ROUTE_HD_MC-VAL_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ROUTE_HD_MC-VAL_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VAL_TO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_ROUTE_HD_MC-VAL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ROUTE_HD_MC-VAL_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LWH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ROUTE_HD_MC-LWH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ROUTE_HD_MC-LWH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WGTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ROUTE_HD_MC-WGTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ROUTE_HD_MC-WGTUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ROUTE_HD_MC-VOLUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ROUTE_HD_MC-VOLUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_ROUTE_HD_MC_STR,
ID_ROUTE TYPE STRING,
VAL_FROM TYPE STRING,
VAL_TO TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
LWH_UOM TYPE STRING,
WGT_MIN_SINGLE TYPE STRING,
WGT_MAX_SINGLE TYPE STRING,
WGT_MIN_TOTAL TYPE STRING,
WGT_MAX_TOTAL TYPE STRING,
WGTUOM TYPE STRING,
VOL_MIN_SINGLE TYPE STRING,
VOL_MAX_SINGLE TYPE STRING,
VOL_MIN_TOTAL TYPE STRING,
VOL_MAX_TOTAL TYPE STRING,
VOLUOM TYPE STRING,
GTS_GROUP TYPE STRING,
EHS_CHECK TYPE STRING,
DG_CATEGORY TYPE STRING,
CD_LOCNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_ROUTE_HD_MC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-ID_ROUTE sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VAL_FROM sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VAL_TO sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-LENGTH sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WIDTH sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-HEIGHT sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-LWH_UOM sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WGT_MIN_SINGLE sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WGT_MAX_SINGLE sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WGT_MIN_TOTAL sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WGT_MAX_TOTAL sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-WGTUOM sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VOL_MIN_SINGLE sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VOL_MAX_SINGLE sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VOL_MIN_TOTAL sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VOL_MAX_TOTAL sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-VOLUOM sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-GTS_GROUP sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-EHS_CHECK sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-DG_CATEGORY sy-vline
WA_/SCWM/S_ROUTE_HD_MC_STR-CD_LOCNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.