ABAP Select data from SAP table /SCWM/S_QUI_PINSP_STOCK_VIEW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_QUI_PINSP_STOCK_VIEW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_QUI_PINSP_STOCK_VIEW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_QUI_PINSP_STOCK_VIEW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_QUI_PINSP_STOCK_VIEW TYPE STANDARD TABLE OF /SCWM/S_QUI_PINSP_STOCK_VIEW,
      WA_/SCWM/S_QUI_PINSP_STOCK_VIEW TYPE /SCWM/S_QUI_PINSP_STOCK_VIEW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_QUI_PINSP_STOCK_VIEW> TYPE /SCWM/S_QUI_PINSP_STOCK_VIEW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_QUI_PINSP_STOCK_VIEW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_QUI_PINSP_STOCK_VIEW
  INTO TABLE IT_/SCWM/S_QUI_PINSP_STOCK_VIEW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_QUI_PINSP_STOCK_VIEW
*  INTO TABLE @DATA(IT_/SCWM/S_QUI_PINSP_STOCK_VIEW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_QUI_PINSP_STOCK_VIEW INDEX 1 INTO DATA(WA_/SCWM/S_QUI_PINSP_STOCK_VIEW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_QUI_PINSP_STOCK_VIEW ASSIGNING </SCWM/S_QUI_PINSP_STOCK_VIEW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_QUI_PINSP_STOCK_VIEW>-GUID_HU = 1.
</SCWM/S_QUI_PINSP_STOCK_VIEW>-GUID_STOCK = 1.
</SCWM/S_QUI_PINSP_STOCK_VIEW>-GUID_STOCK0 = 1.
</SCWM/S_QUI_PINSP_STOCK_VIEW>-GUID_QENTITY = 1.
</SCWM/S_QUI_PINSP_STOCK_VIEW>-QIOT = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_QUI_PINSP_STOCK_VIEW INTO WA_/SCWM/S_QUI_PINSP_STOCK_VIEW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-INSPTYP, sy-vline,
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-SN_STOCK, sy-vline,
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-BATCH_REQ, sy-vline,
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-ITMS_MAN_DELETED, sy-vline,
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-QENTITY_EXTID, sy-vline,
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-REFRMA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_QUI_PINSP_STOCK_VIEW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_QUI_PINSP_STOCK_VIEW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_QUI_PINSP_STOCK_VIEW INTO WA_/SCWM/S_QUI_PINSP_STOCK_VIEW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field QENTITY_EXTID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-QENTITY_EXTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-QENTITY_EXTID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID_OLD CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATID_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATID_OLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-CWUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QUI_PINSP_STOCK_VIEW-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR,
GUID_HU TYPE STRING,
GUID_STOCK TYPE STRING,
GUID_STOCK0 TYPE STRING,
GUID_QENTITY TYPE STRING,
QIOT TYPE STRING,
INSPTYP TYPE STRING,
SN_STOCK TYPE STRING,
BATCH_REQ TYPE STRING,
ITMS_MAN_DELETED TYPE STRING,
QENTITY_EXTID TYPE STRING,
REFRMA TYPE STRING,
RMA_NOT_VALID TYPE STRING,
MATID TYPE STRING,
MATID_OLD TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
BATCHID TYPE STRING,
BATCHID_OLD TYPE STRING,
CHARG TYPE STRING,
VFDAT TYPE STRING,
VFDAT_OLD TYPE STRING,
LGNUM TYPE STRING,
QUAN TYPE STRING,
ALTME TYPE STRING,
NO_DIFF TYPE STRING,
EXCCODE TYPE STRING,
STATUS TYPE STRING,
CWUNIT TYPE STRING,
CWREL TYPE STRING,
CWREQ TYPE STRING,
LMREL TYPE STRING,
ENTITLED TYPE STRING,
QUAN_EXACT TYPE STRING,
SAMPLE_SIZE_EXT TYPE STRING,
BIN TYPE STRING,
MEINS TYPE STRING,
BSKEY TYPE STRING,
IELM_IF TYPE STRING,
CELM_IF TYPE STRING,
DIFFCNT TYPE STRING,
CWQUAN TYPE STRING,
INSPINBUOM TYPE STRING,
INSPECTOR TYPE STRING,
LOCK_FAILED TYPE STRING,
CLOSE_HU TYPE STRING,
COMPLAINT_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-GUID_HU sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-GUID_STOCK sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-GUID_STOCK0 sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-GUID_QENTITY sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-QIOT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-INSPTYP sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-SN_STOCK sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-BATCH_REQ sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-ITMS_MAN_DELETED sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-QENTITY_EXTID sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-REFRMA sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-RMA_NOT_VALID sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-MATID sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-MATID_OLD sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-MATNR sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-MAKTX sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-BATCHID sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-BATCHID_OLD sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CHARG sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-VFDAT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-VFDAT_OLD sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-LGNUM sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-QUAN sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-ALTME sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-NO_DIFF sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-EXCCODE sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-STATUS sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CWUNIT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CWREL sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CWREQ sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-LMREL sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-ENTITLED sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-QUAN_EXACT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-SAMPLE_SIZE_EXT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-BIN sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-MEINS sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-BSKEY sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-IELM_IF sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CELM_IF sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-DIFFCNT sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CWQUAN sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-INSPINBUOM sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-INSPECTOR sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-LOCK_FAILED sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-CLOSE_HU sy-vline
WA_/SCWM/S_QUI_PINSP_STOCK_VIEW_STR-COMPLAINT_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.