ABAP Select data from SAP table /SCWM/S_QI_INSPRULE_ATTRIB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_QI_INSPRULE_ATTRIB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_QI_INSPRULE_ATTRIB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_QI_INSPRULE_ATTRIB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_QI_INSPRULE_ATTRIB TYPE STANDARD TABLE OF /SCWM/S_QI_INSPRULE_ATTRIB,
      WA_/SCWM/S_QI_INSPRULE_ATTRIB TYPE /SCWM/S_QI_INSPRULE_ATTRIB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_QI_INSPRULE_ATTRIB> TYPE /SCWM/S_QI_INSPRULE_ATTRIB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_QI_INSPRULE_ATTRIB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_QI_INSPRULE_ATTRIB
  INTO TABLE IT_/SCWM/S_QI_INSPRULE_ATTRIB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_QI_INSPRULE_ATTRIB
*  INTO TABLE @DATA(IT_/SCWM/S_QI_INSPRULE_ATTRIB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_QI_INSPRULE_ATTRIB INDEX 1 INTO DATA(WA_/SCWM/S_QI_INSPRULE_ATTRIB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_QI_INSPRULE_ATTRIB ASSIGNING </SCWM/S_QI_INSPRULE_ATTRIB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_QI_INSPRULE_ATTRIB>-INSP_PROC = 1.
</SCWM/S_QI_INSPRULE_ATTRIB>-DMOD_RULE_ID = 1.
</SCWM/S_QI_INSPRULE_ATTRIB>-DCOD_BUND_ID = 1.
</SCWM/S_QI_INSPRULE_ATTRIB>-DMOD_CRIT_ID = 1.
</SCWM/S_QI_INSPRULE_ATTRIB>-AUTH_GROUP = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_QI_INSPRULE_ATTRIB INTO WA_/SCWM/S_QI_INSPRULE_ATTRIB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_TYPE, sy-vline,
WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_SIZE_FIX, sy-vline,
WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_UNIT, sy-vline,
WA_/SCWM/S_QI_INSPRULE_ATTRIB-NUMB_ACCEPT, sy-vline,
WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_SIZE_PRC, sy-vline,
WA_/SCWM/S_QI_INSPRULE_ATTRIB-NUMB_ACCEPT_PRC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_QI_INSPRULE_ATTRIB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_QI_INSPRULE_ATTRIB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_QI_INSPRULE_ATTRIB INTO WA_/SCWM/S_QI_INSPRULE_ATTRIB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field SAMPLE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QI_INSPRULE_ATTRIB-SAMPLE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DURAUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QI_INSPRULE_ATTRIB-DURAUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QI_INSPRULE_ATTRIB-DURAUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_QI_INSPRULE_ATTRIB_STR,
INSP_PROC TYPE STRING,
DMOD_RULE_ID TYPE STRING,
DCOD_BUND_ID TYPE STRING,
DMOD_CRIT_ID TYPE STRING,
AUTH_GROUP TYPE STRING,
SAMPLE_TYPE TYPE STRING,
SAMPLE_SIZE_FIX TYPE STRING,
SAMPLE_UNIT TYPE STRING,
NUMB_ACCEPT TYPE STRING,
SAMPLE_SIZE_PRC TYPE STRING,
NUMB_ACCEPT_PRC TYPE STRING,
SAMP_SCHM_ID TYPE STRING,
INSP_LEVEL TYPE STRING,
INSP_SEVERITY TYPE STRING,
AQL_VALUE TYPE STRING,
CRULE_SAMPSIZE TYPE STRING,
VALUATION_MODE TYPE STRING,
NR_RANGE_ID TYPE STRING,
ACTVT_PROF TYPE STRING,
ITEM_DCBD_ID TYPE STRING,
ELEMENT_TYPE TYPE STRING,
SAMP_DCBD_ID TYPE STRING,
SYST_ID TYPE STRING,
INST_ID TYPE STRING,
FIND_TYPE_ID TYPE STRING,
CAT_FILTER_ID TYPE STRING,
PROCS TYPE STRING,
RLGRP TYPE STRING,
CATLOCN TYPE STRING,
TOREL TYPE STRING,
FUREL TYPE STRING,
PROCTY TYPE STRING,
DURATION TYPE STRING,
DURAUNIT TYPE STRING,
QDOC_CNTRL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-INSP_PROC sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-DMOD_RULE_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-DCOD_BUND_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-DMOD_CRIT_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-AUTH_GROUP sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMPLE_TYPE sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMPLE_SIZE_FIX sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMPLE_UNIT sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-NUMB_ACCEPT sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMPLE_SIZE_PRC sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-NUMB_ACCEPT_PRC sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMP_SCHM_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-INSP_LEVEL sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-INSP_SEVERITY sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-AQL_VALUE sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-CRULE_SAMPSIZE sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-VALUATION_MODE sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-NR_RANGE_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-ACTVT_PROF sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-ITEM_DCBD_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-ELEMENT_TYPE sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SAMP_DCBD_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-SYST_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-INST_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-FIND_TYPE_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-CAT_FILTER_ID sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-PROCS sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-RLGRP sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-CATLOCN sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-TOREL sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-FUREL sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-PROCTY sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-DURATION sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-DURAUNIT sy-vline
WA_/SCWM/S_QI_INSPRULE_ATTRIB_STR-QDOC_CNTRL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.