ABAP Select data from SAP table /SCWM/S_PRODUCT_MIG_MC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PRODUCT_MIG_MC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PRODUCT_MIG_MC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_PRODUCT_MIG_MC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_PRODUCT_MIG_MC TYPE STANDARD TABLE OF /SCWM/S_PRODUCT_MIG_MC,
      WA_/SCWM/S_PRODUCT_MIG_MC TYPE /SCWM/S_PRODUCT_MIG_MC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_PRODUCT_MIG_MC> TYPE /SCWM/S_PRODUCT_MIG_MC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PRODUCT_MIG_MC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_PRODUCT_MIG_MC
  INTO TABLE IT_/SCWM/S_PRODUCT_MIG_MC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_PRODUCT_MIG_MC
*  INTO TABLE @DATA(IT_/SCWM/S_PRODUCT_MIG_MC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_PRODUCT_MIG_MC INDEX 1 INTO DATA(WA_/SCWM/S_PRODUCT_MIG_MC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_PRODUCT_MIG_MC ASSIGNING </SCWM/S_PRODUCT_MIG_MC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PRODUCT_MIG_MC>-SENDER_TECHNICAL_ID = 1.
</SCWM/S_PRODUCT_MIG_MC>-EWM_LGNUM = 1.
</SCWM/S_PRODUCT_MIG_MC>-EWM_PRODNO = 1.
</SCWM/S_PRODUCT_MIG_MC>-EWM_ENTITLED = 1.
</SCWM/S_PRODUCT_MIG_MC>-PROCPRFL = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_PRODUCT_MIG_MC INTO WA_/SCWM/S_PRODUCT_MIG_MC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_PRODUCT_MIG_MC-PTDETIND, sy-vline,
WA_/SCWM/S_PRODUCT_MIG_MC-WRKLDGR, sy-vline,
WA_/SCWM/S_PRODUCT_MIG_MC-DRDETGR, sy-vline,
WA_/SCWM/S_PRODUCT_MIG_MC-VASVCP, sy-vline,
WA_/SCWM/S_PRODUCT_MIG_MC-SLRQ_MIN, sy-vline,
WA_/SCWM/S_PRODUCT_MIG_MC-PUT_STRA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PRODUCT_MIG_MC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PRODUCT_MIG_MC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PRODUCT_MIG_MC INTO WA_/SCWM/S_PRODUCT_MIG_MC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field EWM_PRODNO CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_PRODUCT_MIG_MC-EWM_PRODNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PRODUCT_MIG_MC-EWM_PRODNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EWM_ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PRODUCT_MIG_MC-EWM_ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PRODUCT_MIG_MC-EWM_ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAXQTY_UOM_DSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PRODUCT_MIG_MC-MAXQTY_UOM_DSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PRODUCT_MIG_MC-MAXQTY_UOM_DSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MINQTY_UOM_DSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PRODUCT_MIG_MC-MINQTY_UOM_DSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PRODUCT_MIG_MC-MINQTY_UOM_DSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field REPQTY_UOM_DSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PRODUCT_MIG_MC-REPQTY_UOM_DSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PRODUCT_MIG_MC-REPQTY_UOM_DSP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PRODUCT_MIG_MC_STR,
SENDER_TECHNICAL_ID TYPE STRING,
EWM_LGNUM TYPE STRING,
EWM_PRODNO TYPE STRING,
EWM_ENTITLED TYPE STRING,
PROCPRFL TYPE STRING,
PTDETIND TYPE STRING,
WRKLDGR TYPE STRING,
DRDETGR TYPE STRING,
VASVCP TYPE STRING,
SLRQ_MIN TYPE STRING,
PUT_STRA TYPE STRING,
PUT_STRA_FIX TYPE STRING,
PUT_STRA_PLAN TYPE STRING,
LGBKZ TYPE STRING,
LPTYP TYPE STRING,
BLOCK TYPE STRING,
REM_STRA TYPE STRING,
REM_STRA_FIX TYPE STRING,
REM_STRA_PLAN TYPE STRING,
STCKDETGR TYPE STRING,
L2SKR TYPE STRING,
DEMQTY TYPE STRING,
DEMQTY_FIX TYPE STRING,
NOSOI TYPE STRING,
NOSOI_FIX TYPE STRING,
RSQTY TYPE STRING,
RSQTY_FIX TYPE STRING,
DEMTYP TYPE STRING,
CONCSTAT TYPE STRING,
LASTSLOT TYPE STRING,
WGHTIND TYPE STRING,
WGHTIND_FIX TYPE STRING,
VOLIND TYPE STRING,
VOLIND_FIX TYPE STRING,
LGTHIND TYPE STRING,
LGTHIND_FIX TYPE STRING,
WDTHIND TYPE STRING,
WDTHIND_FIX TYPE STRING,
HGHTIND TYPE STRING,
HGHTIND_FIX TYPE STRING,
CCIND TYPE STRING,
CCIND_FIX TYPE STRING,
DOCBATCH TYPE STRING,
BACKFLUSH_PROD TYPE STRING,
KIT_FIXED_QUAN TYPE STRING,
MEDI_APROF_WH TYPE STRING,
QUANCLA_MERCH TYPE STRING,
PUOM_WH TYPE STRING,
KZZUL TYPE STRING,
RATIODIM TYPE STRING,
QGRP_WH TYPE STRING,
EWM_LGTYP TYPE STRING,
FIXBIN TYPE STRING,
SECTIND TYPE STRING,
SECTIND_FIX TYPE STRING,
SECTIND_PLAN TYPE STRING,
BINTYPE TYPE STRING,
BINTYPE_FIX TYPE STRING,
BINTYPE_PLAN TYPE STRING,
MAXFIXBIN TYPE STRING,
MAXFIXBIN_FIX TYPE STRING,
MAXFIXBIN_PLAN TYPE STRING,
MAXQTY TYPE STRING,
MAXQTY_PLAN TYPE STRING,
MAXQTY_UOM_DSP TYPE STRING,
MINQTY TYPE STRING,
MINQTY_PLAN TYPE STRING,
MINQTY_UOM_DSP TYPE STRING,
REPQTY TYPE STRING,
REPQTY_PLAN TYPE STRING,
REPQTY_UOM_DSP TYPE STRING,
RMMQTY_FIX TYPE STRING,
PERMXQTY TYPE STRING,
SPLITTH TYPE STRING,
SPLITPUT TYPE STRING,
NORPLN TYPE STRING,
BINSRCH TYPE STRING,
QUANCLA TYPE STRING,
QUANCLAPUT TYPE STRING,
SEQPUT TYPE STRING,
SEQPUT_FIX TYPE STRING,
SEQPUT_PLAN TYPE STRING,
SKIPPTW TYPE STRING,
SKIPPTW_FIX TYPE STRING,
SKIPPTW_PLAN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PRODUCT_MIG_MC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SENDER_TECHNICAL_ID sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-EWM_LGNUM sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-EWM_PRODNO sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-EWM_ENTITLED sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PROCPRFL sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PTDETIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-WRKLDGR sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-DRDETGR sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-VASVCP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SLRQ_MIN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PUT_STRA sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PUT_STRA_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PUT_STRA_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-LGBKZ sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-LPTYP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BLOCK sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REM_STRA sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REM_STRA_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REM_STRA_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-STCKDETGR sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-L2SKR sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-DEMQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-DEMQTY_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-NOSOI sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-NOSOI_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-RSQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-RSQTY_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-DEMTYP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-CONCSTAT sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-LASTSLOT sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-WGHTIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-WGHTIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-VOLIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-VOLIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-LGTHIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-LGTHIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-WDTHIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-WDTHIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-HGHTIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-HGHTIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-CCIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-CCIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-DOCBATCH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BACKFLUSH_PROD sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-KIT_FIXED_QUAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MEDI_APROF_WH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-QUANCLA_MERCH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PUOM_WH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-KZZUL sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-RATIODIM sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-QGRP_WH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-EWM_LGTYP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-FIXBIN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SECTIND sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SECTIND_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SECTIND_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BINTYPE sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BINTYPE_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BINTYPE_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXFIXBIN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXFIXBIN_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXFIXBIN_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXQTY_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MAXQTY_UOM_DSP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MINQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MINQTY_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-MINQTY_UOM_DSP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REPQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REPQTY_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-REPQTY_UOM_DSP sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-RMMQTY_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-PERMXQTY sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SPLITTH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SPLITPUT sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-NORPLN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-BINSRCH sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-QUANCLA sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-QUANCLAPUT sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SEQPUT sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SEQPUT_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SEQPUT_PLAN sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SKIPPTW sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SKIPPTW_FIX sy-vline
WA_/SCWM/S_PRODUCT_MIG_MC_STR-SKIPPTW_PLAN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.