ABAP Select data from SAP table /SCWM/S_PACK_VIEW_TO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PACK_VIEW_TO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PACK_VIEW_TO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_PACK_VIEW_TO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_PACK_VIEW_TO TYPE STANDARD TABLE OF /SCWM/S_PACK_VIEW_TO,
      WA_/SCWM/S_PACK_VIEW_TO TYPE /SCWM/S_PACK_VIEW_TO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_PACK_VIEW_TO> TYPE /SCWM/S_PACK_VIEW_TO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PACK_VIEW_TO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_PACK_VIEW_TO
  INTO TABLE IT_/SCWM/S_PACK_VIEW_TO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_PACK_VIEW_TO
*  INTO TABLE @DATA(IT_/SCWM/S_PACK_VIEW_TO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_PACK_VIEW_TO INDEX 1 INTO DATA(WA_/SCWM/S_PACK_VIEW_TO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_PACK_VIEW_TO ASSIGNING </SCWM/S_PACK_VIEW_TO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PACK_VIEW_TO>-MANDT = 1.
</SCWM/S_PACK_VIEW_TO>-LGNUM = 1.
</SCWM/S_PACK_VIEW_TO>-TANUM = 1.
</SCWM/S_PACK_VIEW_TO>-MEINS = 1.
</SCWM/S_PACK_VIEW_TO>-ALTME = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_PACK_VIEW_TO INTO WA_/SCWM/S_PACK_VIEW_TO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_PACK_VIEW_TO-QUANM, sy-vline,
WA_/SCWM/S_PACK_VIEW_TO-QUANA, sy-vline,
WA_/SCWM/S_PACK_VIEW_TO-QUANP, sy-vline,
WA_/SCWM/S_PACK_VIEW_TO-CWQUAN, sy-vline,
WA_/SCWM/S_PACK_VIEW_TO-CWQUANA, sy-vline,
WA_/SCWM/S_PACK_VIEW_TO-CWUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PACK_VIEW_TO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PACK_VIEW_TO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PACK_VIEW_TO INTO WA_/SCWM/S_PACK_VIEW_TO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPH0, internal->external for field TANUM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-TANUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-TANUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-CWUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-OWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-QDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-QDOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QITEMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-QITEMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-QITEMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PACK_VIEW_TO-INSPDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACK_VIEW_TO-INSPDOCNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PACK_VIEW_TO_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
TANUM TYPE STRING,
MEINS TYPE STRING,
ALTME TYPE STRING,
QUANM TYPE STRING,
QUANA TYPE STRING,
QUANP TYPE STRING,
CWQUAN TYPE STRING,
CWQUANA TYPE STRING,
CWUNIT TYPE STRING,
REASON TYPE STRING,
FLGHUTO TYPE STRING,
PROCTY TYPE STRING,
TRART TYPE STRING,
ACT_TYPE TYPE STRING,
PRCES TYPE STRING,
PROCS TYPE STRING,
TOSTAT TYPE STRING,
VLPLA TYPE STRING,
NLPLA TYPE STRING,
MATID TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
BATCHID TYPE STRING,
CHARG TYPE STRING,
CAT TYPE STRING,
CAT_TEXT TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
ENTITLED_TEXT TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
OWNER_TEXT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCCAT_TEXT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_DOCNO_EXT TYPE STRING,
STOCK_ITMNO TYPE STRING,
STOCK_USAGE TYPE STRING,
STOCK_USAGE_TEXT TYPE STRING,
STREF_DOCCAT TYPE STRING,
STREF_DOCCAT_TEXT TYPE STRING,
WDATU TYPE STRING,
UI_WDATU TYPE STRING,
UI_WDATT TYPE STRING,
VFDAT TYPE STRING,
COO TYPE STRING,
COO_TEXT TYPE STRING,
BRESTR TYPE STRING,
IDPLATE TYPE STRING,
QDOCCAT TYPE STRING,
QDOCCAT_TEXT TYPE STRING,
QDOCID TYPE STRING,
QITMID TYPE STRING,
QDOCNO TYPE STRING,
QITEMNO TYPE STRING,
INSPTYP TYPE STRING,
INSPTYP_TEXT TYPE STRING,
INSPID TYPE STRING,
INSPDOCNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PACK_VIEW_TO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-MANDT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-LGNUM sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-TANUM sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-MEINS sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-ALTME sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QUANM sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QUANA sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QUANP sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CWQUAN sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CWQUANA sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CWUNIT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-REASON sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-FLGHUTO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-PROCTY sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-TRART sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-ACT_TYPE sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-PRCES sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-PROCS sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-TOSTAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-VLPLA sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-NLPLA sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-MATID sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-MATNR sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-MAKTX sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-BATCHID sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CHARG sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-CAT_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-ENTITLED sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-ENTITLED_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-OWNER sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-OWNER_ROLE sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-OWNER_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_DOCCAT_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_DOCNO_EXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STOCK_USAGE_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STREF_DOCCAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-STREF_DOCCAT_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-WDATU sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-UI_WDATU sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-UI_WDATT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-VFDAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-COO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-COO_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-BRESTR sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-IDPLATE sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QDOCCAT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QDOCCAT_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QDOCID sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QITMID sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QDOCNO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-QITEMNO sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-INSPTYP sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-INSPTYP_TEXT sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-INSPID sy-vline
WA_/SCWM/S_PACK_VIEW_TO_STR-INSPDOCNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.