ABAP Select data from SAP table /SCWM/S_MFG_RCV_HU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_MFG_RCV_HU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_MFG_RCV_HU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_MFG_RCV_HU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_MFG_RCV_HU TYPE STANDARD TABLE OF /SCWM/S_MFG_RCV_HU,
      WA_/SCWM/S_MFG_RCV_HU TYPE /SCWM/S_MFG_RCV_HU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_MFG_RCV_HU> TYPE /SCWM/S_MFG_RCV_HU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_MFG_RCV_HU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_MFG_RCV_HU
  INTO TABLE IT_/SCWM/S_MFG_RCV_HU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_MFG_RCV_HU
*  INTO TABLE @DATA(IT_/SCWM/S_MFG_RCV_HU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_MFG_RCV_HU INDEX 1 INTO DATA(WA_/SCWM/S_MFG_RCV_HU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_MFG_RCV_HU ASSIGNING </SCWM/S_MFG_RCV_HU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_MFG_RCV_HU>-LINE_ID = 1.
</SCWM/S_MFG_RCV_HU>-MATERIAL = 1.
</SCWM/S_MFG_RCV_HU>-SHIP_MAT = 1.
</SCWM/S_MFG_RCV_HU>-ORDER_ITNO = 1.
</SCWM/S_MFG_RCV_HU>-RESERVATION_NUMBER = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_MFG_RCV_HU INTO WA_/SCWM/S_MFG_RCV_HU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_MFG_RCV_HU-RESERVATION_ITEM, sy-vline,
WA_/SCWM/S_MFG_RCV_HU-RESERVATION_TYPE, sy-vline,
WA_/SCWM/S_MFG_RCV_HU-SUPPLY_AREA, sy-vline,
WA_/SCWM/S_MFG_RCV_HU-BATCH, sy-vline,
WA_/SCWM/S_MFG_RCV_HU-EXPIRYDATE, sy-vline,
WA_/SCWM/S_MFG_RCV_HU-PROD_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_MFG_RCV_HU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_MFG_RCV_HU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_MFG_RCV_HU INTO WA_/SCWM/S_MFG_RCV_HU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SHIP_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-SHIP_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-SHIP_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SALES_ORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-SALES_ORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-SALES_ORD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field WBS_ELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-WBS_ELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-WBS_ELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HU_EXID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-HU_EXID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-HU_EXID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VAL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-VAL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-VAL_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_MFG_RCV_HU-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MFG_RCV_HU-HUIDENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_MFG_RCV_HU_STR,
LINE_ID TYPE STRING,
MATERIAL TYPE STRING,
SHIP_MAT TYPE STRING,
ORDER_ITNO TYPE STRING,
RESERVATION_NUMBER TYPE STRING,
RESERVATION_ITEM TYPE STRING,
RESERVATION_TYPE TYPE STRING,
SUPPLY_AREA TYPE STRING,
BATCH TYPE STRING,
EXPIRYDATE TYPE STRING,
PROD_DATE TYPE STRING,
COO TYPE STRING,
SPECIAL_STOCK TYPE STRING,
SALES_ORD TYPE STRING,
S_ORD_ITEM TYPE STRING,
WBS_ELEM TYPE STRING,
HU_EXID TYPE STRING,
HU_EXID_TYPE TYPE STRING,
QUANTITY TYPE STRING,
UOM TYPE STRING,
UOM_ISO TYPE STRING,
VAL_QUANTITY TYPE STRING,
VAL_UOM TYPE STRING,
VAL_UOM_ISO TYPE STRING,
GM_BIN TYPE STRING,
HUTYP TYPE STRING,
HUIDENT TYPE STRING,
NOEXIDVASHUIDENT TYPE STRING,
BATCH_RESTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_MFG_RCV_HU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-LINE_ID sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-MATERIAL sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-SHIP_MAT sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-ORDER_ITNO sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-RESERVATION_NUMBER sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-RESERVATION_ITEM sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-RESERVATION_TYPE sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-SUPPLY_AREA sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-BATCH sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-EXPIRYDATE sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-PROD_DATE sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-COO sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-SPECIAL_STOCK sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-SALES_ORD sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-S_ORD_ITEM sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-WBS_ELEM sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-HU_EXID sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-HU_EXID_TYPE sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-QUANTITY sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-UOM sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-UOM_ISO sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-VAL_QUANTITY sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-VAL_UOM sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-VAL_UOM_ISO sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-GM_BIN sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-HUTYP sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-HUIDENT sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-NOEXIDVASHUIDENT sy-vline
WA_/SCWM/S_MFG_RCV_HU_STR-BATCH_RESTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.