ABAP Select data from SAP table /SCWM/S_JIT_CALL_MON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_JIT_CALL_MON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_JIT_CALL_MON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_JIT_CALL_MON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_JIT_CALL_MON TYPE STANDARD TABLE OF /SCWM/S_JIT_CALL_MON,
      WA_/SCWM/S_JIT_CALL_MON TYPE /SCWM/S_JIT_CALL_MON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_JIT_CALL_MON> TYPE /SCWM/S_JIT_CALL_MON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_JIT_CALL_MON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_JIT_CALL_MON
  INTO TABLE IT_/SCWM/S_JIT_CALL_MON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_JIT_CALL_MON
*  INTO TABLE @DATA(IT_/SCWM/S_JIT_CALL_MON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_JIT_CALL_MON INDEX 1 INTO DATA(WA_/SCWM/S_JIT_CALL_MON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_JIT_CALL_MON ASSIGNING </SCWM/S_JIT_CALL_MON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_JIT_CALL_MON>-STATUS_BLOCKED_OVERALL = 1.
</SCWM/S_JIT_CALL_MON>-STATUS_BLOCKED_PLANNING = 1.
</SCWM/S_JIT_CALL_MON>-CALL_NUM = 1.
</SCWM/S_JIT_CALL_MON>-CALL_NUM_EXT = 1.
</SCWM/S_JIT_CALL_MON>-CALL_TYPE = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_JIT_CALL_MON INTO WA_/SCWM/S_JIT_CALL_MON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_JIT_CALL_MON-VEHICLE_IDENT, sy-vline,
WA_/SCWM/S_JIT_CALL_MON-SEQUENCE_NUM_INT, sy-vline,
WA_/SCWM/S_JIT_CALL_MON-PLANNED_ORDER, sy-vline,
WA_/SCWM/S_JIT_CALL_MON-DOCCAT, sy-vline,
WA_/SCWM/S_JIT_CALL_MON-DOCNO, sy-vline,
WA_/SCWM/S_JIT_CALL_MON-DOCID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_JIT_CALL_MON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_JIT_CALL_MON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_JIT_CALL_MON INTO WA_/SCWM/S_JIT_CALL_MON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CALL_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_JIT_CALL_MON-CALL_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_JIT_CALL_MON-CALL_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_JIT_CALL_MON-DOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_JIT_CALL_MON-DOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field CREATED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_JIT_CALL_MON-CREATED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_JIT_CALL_MON-CREATED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field CHANGED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_JIT_CALL_MON-CHANGED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_JIT_CALL_MON-CHANGED_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_JIT_CALL_MON_STR,
STATUS_BLOCKED_OVERALL TYPE STRING,
STATUS_BLOCKED_PLANNING TYPE STRING,
CALL_NUM TYPE STRING,
CALL_NUM_EXT TYPE STRING,
CALL_TYPE TYPE STRING,
VEHICLE_IDENT TYPE STRING,
SEQUENCE_NUM_INT TYPE STRING,
PLANNED_ORDER TYPE STRING,
DOCCAT TYPE STRING,
DOCNO TYPE STRING,
DOCID TYPE STRING,
JIT_LFECYCLE_STATUS_VALUE TYPE STRING,
JIT_LFECYCLE_STATUS TYPE STRING,
STATUS_PL_WM_ACTIVITY TYPE STRING,
STATUS_VALUE_DWP_I TYPE STRING,
STATUS_INT_MOVEMENT TYPE STRING,
STATUS_VALUE_DWI_I TYPE STRING,
STATUS_VALUE_TRANSFERRED TYPE STRING,
STATUS_TRANSFERRED TYPE STRING,
STATUS_VALUE_DBO_I TYPE STRING,
STATUS_VALUE_DBV_I TYPE STRING,
PRIORITY TYPE STRING,
PRIORITY_DESC TYPE STRING,
WAVEFLG_HEAD TYPE STRING,
WAVEFLG_HEAD_DESC TYPE STRING,
MISSING_MATERIAL TYPE STRING,
CREATED_AT TYPE STRING,
CREATED_AT_DATE TYPE STRING,
CREATED_AT_TIME TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
CHANGED_AT_DATE TYPE STRING,
CHANGED_AT_TIME TYPE STRING,
CHANGED_BY TYPE STRING,
JIT_HEADER_DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_JIT_CALL_MON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_BLOCKED_OVERALL sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_BLOCKED_PLANNING sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CALL_NUM sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CALL_NUM_EXT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CALL_TYPE sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-VEHICLE_IDENT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-SEQUENCE_NUM_INT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-PLANNED_ORDER sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-DOCCAT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-DOCNO sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-DOCID sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-JIT_LFECYCLE_STATUS_VALUE sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-JIT_LFECYCLE_STATUS sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_PL_WM_ACTIVITY sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_VALUE_DWP_I sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_INT_MOVEMENT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_VALUE_DWI_I sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_VALUE_TRANSFERRED sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_TRANSFERRED sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_VALUE_DBO_I sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-STATUS_VALUE_DBV_I sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-PRIORITY sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-PRIORITY_DESC sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-WAVEFLG_HEAD sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-WAVEFLG_HEAD_DESC sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-MISSING_MATERIAL sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CREATED_AT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CREATED_AT_DATE sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CREATED_AT_TIME sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CREATED_BY sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CHANGED_AT sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CHANGED_AT_DATE sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CHANGED_AT_TIME sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-CHANGED_BY sy-vline
WA_/SCWM/S_JIT_CALL_MON_STR-JIT_HEADER_DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.