ABAP Select data from SAP table /SCWM/S_EWRKL_CUM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_EWRKL_CUM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_EWRKL_CUM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_EWRKL_CUM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_EWRKL_CUM TYPE STANDARD TABLE OF /SCWM/S_EWRKL_CUM,
      WA_/SCWM/S_EWRKL_CUM TYPE /SCWM/S_EWRKL_CUM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_EWRKL_CUM> TYPE /SCWM/S_EWRKL_CUM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_EWRKL_CUM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_EWRKL_CUM
  INTO TABLE IT_/SCWM/S_EWRKL_CUM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_EWRKL_CUM
*  INTO TABLE @DATA(IT_/SCWM/S_EWRKL_CUM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_EWRKL_CUM INDEX 1 INTO DATA(WA_/SCWM/S_EWRKL_CUM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_EWRKL_CUM ASSIGNING </SCWM/S_EWRKL_CUM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_EWRKL_CUM>-SCUGUID = 1.
</SCWM/S_EWRKL_CUM>-PROCS = 1.
</SCWM/S_EWRKL_CUM>-LMAREA = 1.
</SCWM/S_EWRKL_CUM>-LMOBJTY = 1.
</SCWM/S_EWRKL_CUM>-NUMDOC = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_EWRKL_CUM INTO WA_/SCWM/S_EWRKL_CUM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_EWRKL_CUM-DURA_PLAN, sy-vline,
WA_/SCWM/S_EWRKL_CUM-DURA_PLAN_ADJ, sy-vline,
WA_/SCWM/S_EWRKL_CUM-DURA_ACT, sy-vline,
WA_/SCWM/S_EWRKL_CUM-UNIT_T, sy-vline,
WA_/SCWM/S_EWRKL_CUM-WEIGHT, sy-vline,
WA_/SCWM/S_EWRKL_CUM-UNIT_W, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_EWRKL_CUM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_EWRKL_CUM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_EWRKL_CUM INTO WA_/SCWM/S_EWRKL_CUM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_T CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EWRKL_CUM-UNIT_T IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EWRKL_CUM-UNIT_T.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EWRKL_CUM-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EWRKL_CUM-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EWRKL_CUM-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EWRKL_CUM-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_D CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EWRKL_CUM-UNIT_D IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EWRKL_CUM-UNIT_D.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_EWRKL_CUM_STR,
SCUGUID TYPE STRING,
PROCS TYPE STRING,
LMAREA TYPE STRING,
LMOBJTY TYPE STRING,
NUMDOC TYPE STRING,
DURA_PLAN TYPE STRING,
DURA_PLAN_ADJ TYPE STRING,
DURA_ACT TYPE STRING,
UNIT_T TYPE STRING,
WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
VOLUM TYPE STRING,
UNIT_V TYPE STRING,
TRDIST TYPE STRING,
UNIT_D TYPE STRING,
CAPA TYPE STRING,
NUMSO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_EWRKL_CUM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-SCUGUID sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-PROCS sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-LMAREA sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-LMOBJTY sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-NUMDOC sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-DURA_PLAN sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-DURA_PLAN_ADJ sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-DURA_ACT sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-UNIT_T sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-WEIGHT sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-UNIT_W sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-VOLUM sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-UNIT_V sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-TRDIST sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-UNIT_D sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-CAPA sy-vline
WA_/SCWM/S_EWRKL_CUM_STR-NUMSO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.