ABAP Select data from SAP table /SCWM/S_BIF_TOLDAP_RQ_ADDPTY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_BIF_TOLDAP_RQ_ADDPTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_BIF_TOLDAP_RQ_ADDPTY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_BIF_TOLDAP_RQ_ADDPTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY TYPE STANDARD TABLE OF /SCWM/S_BIF_TOLDAP_RQ_ADDPTY, WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY TYPE /SCWM/S_BIF_TOLDAP_RQ_ADDPTY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_BIF_TOLDAP_RQ_ADDPTY> TYPE /SCWM/S_BIF_TOLDAP_RQ_ADDPTY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_BIF_TOLDAP_RQ_ADDPTY INTO TABLE IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_BIF_TOLDAP_RQ_ADDPTY * INTO TABLE @DATA(IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY INDEX 1 INTO DATA(WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY ASSIGNING </SCWM/S_BIF_TOLDAP_RQ_ADDPTY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_BIF_TOLDAP_RQ_ADDPTY>-CONTROLLER = 1.
</SCWM/S_BIF_TOLDAP_RQ_ADDPTY>-PARTY = 1.
</SCWM/S_BIF_TOLDAP_RQ_ADDPTY>-CONTROLLER = 1.
</SCWM/S_BIF_TOLDAP_RQ_ADDPTY>-INTERNAL_ID = 1.
</SCWM/S_BIF_TOLDAP_RQ_ADDPTY>-CONTROLLER = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY INTO WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-SCHEME_ID, sy-vline,
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-SCHEME_AGENCY_ID, sy-vline,
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-VALUE, sy-vline,
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-STANDARD_ID, sy-vline,
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-BUYER_ID, sy-vline,
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY-SELLER_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY INTO WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR,
CONTROLLER TYPE STRING,
PARTY TYPE STRING,
CONTROLLER TYPE STRING,
INTERNAL_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
STANDARD_ID TYPE STRING,
BUYER_ID TYPE STRING,
SELLER_ID TYPE STRING,
PRODUCT_RECIPIENT_ID TYPE STRING,
VENDOR_ID TYPE STRING,
BILL_TO_ID TYPE STRING,
BILL_FROM_ID TYPE STRING,
BIDDER_ID TYPE STRING,
PAYMENT_TRANSACTION_INITIATOR TYPE STRING,
PAYMENT_TRANSACTION_DESTINATED TYPE STRING,
TAX_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
CONTENT TYPE STRING,
CLEARING_HOUSE_ID TYPE STRING,
TYPE_CODE TYPE STRING,
DETERMINATION_METHOD_CODE TYPE STRING,
ADDRESS_REFERENCE TYPE STRING,
CONTROLLER TYPE STRING,
ADDRESS_HOST_UUID TYPE STRING,
ADDRESS_HOST_TYPE_CODE TYPE STRING,
ADDRESS TYPE STRING,
CONTROLLER TYPE STRING,
ORGANISATION_FORMATTED_NAME TYPE STRING,
PERSON_NAME TYPE STRING,
CONTROLLER TYPE STRING,
GIVEN_NAME TYPE STRING,
FAMILY_NAME TYPE STRING,
FUNCTIONAL_TITLE_NAME TYPE STRING,
PHYSICAL_ADDRESS TYPE STRING,
CONTROLLER TYPE STRING,
COUNTRY_CODE TYPE STRING,
REGION_CODE TYPE STRING,
STREET_POSTAL_CODE TYPE STRING,
POBOX_POSTAL_CODE TYPE STRING,
COMPANY_POSTAL_CODE TYPE STRING,
CITY_NAME TYPE STRING,
POBOX_ID TYPE STRING,
STREET_NAME TYPE STRING,
HOUSE_ID TYPE STRING,
COMMUNICATION TYPE STRING,
CONTROLLER TYPE STRING,
CORRESPONDENCE_LANGUAGE_CODE TYPE STRING,
TELEPHONE TYPE STRING,
MOBILE_PHONE TYPE STRING,
FACSIMILE TYPE STRING,
EMAIL TYPE STRING,
WEB TYPE STRING,
CONTACT_PERSON TYPE STRING,
ROLE_CODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PARTY sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-INTERNAL_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-SCHEME_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-SCHEME_AGENCY_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-VALUE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-STANDARD_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-BUYER_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-SELLER_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PRODUCT_RECIPIENT_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-VENDOR_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-BILL_TO_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-BILL_FROM_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-BIDDER_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PAYMENT_TRANSACTION_INITIATOR sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PAYMENT_TRANSACTION_DESTINATED sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-TAX_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-SCHEME_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTENT sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CLEARING_HOUSE_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-TYPE_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-DETERMINATION_METHOD_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ADDRESS_REFERENCE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ADDRESS_HOST_UUID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ADDRESS_HOST_TYPE_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ADDRESS sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ORGANISATION_FORMATTED_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PERSON_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-GIVEN_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-FAMILY_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-FUNCTIONAL_TITLE_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-PHYSICAL_ADDRESS sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-COUNTRY_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-REGION_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-STREET_POSTAL_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-POBOX_POSTAL_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-COMPANY_POSTAL_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CITY_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-POBOX_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-STREET_NAME sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-HOUSE_ID sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-COMMUNICATION sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTROLLER sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CORRESPONDENCE_LANGUAGE_CODE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-TELEPHONE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-MOBILE_PHONE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-FACSIMILE sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-EMAIL sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-WEB sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-CONTACT_PERSON sy-vline
WA_/SCWM/S_BIF_TOLDAP_RQ_ADDPTY_STR-ROLE_CODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.