ABAP Select data from SAP table /SCWM/E1LSUMX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/E1LSUMX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/E1LSUMX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/E1LSUMX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/E1LSUMX TYPE STANDARD TABLE OF /SCWM/E1LSUMX,
      WA_/SCWM/E1LSUMX TYPE /SCWM/E1LSUMX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/E1LSUMX> TYPE /SCWM/E1LSUMX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/E1LSUMX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/E1LSUMX
  INTO TABLE IT_/SCWM/E1LSUMX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/E1LSUMX
*  INTO TABLE @DATA(IT_/SCWM/E1LSUMX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/E1LSUMX INDEX 1 INTO DATA(WA_/SCWM/E1LSUMX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/E1LSUMX ASSIGNING </SCWM/E1LSUMX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/E1LSUMX>-LGNUM = 1.
</SCWM/E1LSUMX>-LENUM = 1.
</SCWM/E1LSUMX>-PROCTY = 1.
</SCWM/E1LSUMX>-LETYP = 1.
</SCWM/E1LSUMX>-BNAME = 1.
ENDLOOP.

LOOP AT IT_/SCWM/E1LSUMX INTO WA_/SCWM/E1LSUMX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/E1LSUMX-KZQUI, sy-vline,
WA_/SCWM/E1LSUMX-NLTYP, sy-vline,
WA_/SCWM/E1LSUMX-NLBER, sy-vline,
WA_/SCWM/E1LSUMX-NLPLA, sy-vline,
WA_/SCWM/E1LSUMX-NLENR, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/SCWM/E1LSUMX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/E1LSUMX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/E1LSUMX INTO WA_/SCWM/E1LSUMX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/E1LSUMX_STR,
LGNUM TYPE STRING,
LENUM TYPE STRING,
PROCTY TYPE STRING,
LETYP TYPE STRING,
BNAME TYPE STRING,
KZQUI TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
NLENR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/E1LSUMX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/E1LSUMX_STR-LGNUM sy-vline
WA_/SCWM/E1LSUMX_STR-LENUM sy-vline
WA_/SCWM/E1LSUMX_STR-PROCTY sy-vline
WA_/SCWM/E1LSUMX_STR-LETYP sy-vline
WA_/SCWM/E1LSUMX_STR-BNAME sy-vline
WA_/SCWM/E1LSUMX_STR-KZQUI sy-vline
WA_/SCWM/E1LSUMX_STR-NLTYP sy-vline
WA_/SCWM/E1LSUMX_STR-NLBER sy-vline
WA_/SCWM/E1LSUMX_STR-NLPLA sy-vline
WA_/SCWM/E1LSUMX_STR-NLENR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.