ABAP Select data from SAP table /SCWM/BAPIOBDLVHDRCON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/BAPIOBDLVHDRCON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/BAPIOBDLVHDRCON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/BAPIOBDLVHDRCON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/BAPIOBDLVHDRCON TYPE STANDARD TABLE OF /SCWM/BAPIOBDLVHDRCON,
      WA_/SCWM/BAPIOBDLVHDRCON TYPE /SCWM/BAPIOBDLVHDRCON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/BAPIOBDLVHDRCON> TYPE /SCWM/BAPIOBDLVHDRCON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/BAPIOBDLVHDRCON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/BAPIOBDLVHDRCON
  INTO TABLE IT_/SCWM/BAPIOBDLVHDRCON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/BAPIOBDLVHDRCON
*  INTO TABLE @DATA(IT_/SCWM/BAPIOBDLVHDRCON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/BAPIOBDLVHDRCON INDEX 1 INTO DATA(WA_/SCWM/BAPIOBDLVHDRCON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/BAPIOBDLVHDRCON ASSIGNING </SCWM/BAPIOBDLVHDRCON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/BAPIOBDLVHDRCON>-DELIV_NUMB = 1.
</SCWM/BAPIOBDLVHDRCON>-GROSS_WT = 1.
</SCWM/BAPIOBDLVHDRCON>-NET_WEIGHT = 1.
</SCWM/BAPIOBDLVHDRCON>-UNIT_OF_WT = 1.
</SCWM/BAPIOBDLVHDRCON>-UNIT_OF_WT_ISO = 1.
ENDLOOP.

LOOP AT IT_/SCWM/BAPIOBDLVHDRCON INTO WA_/SCWM/BAPIOBDLVHDRCON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/BAPIOBDLVHDRCON-VOLUME, sy-vline,
WA_/SCWM/BAPIOBDLVHDRCON-VOLUMEUNIT, sy-vline,
WA_/SCWM/BAPIOBDLVHDRCON-VOLUMEUNIT_ISO, sy-vline,
WA_/SCWM/BAPIOBDLVHDRCON-DOOR, sy-vline,
WA_/SCWM/BAPIOBDLVHDRCON-INCOTERMS1, sy-vline,
WA_/SCWM/BAPIOBDLVHDRCON-INCOTERMS2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/BAPIOBDLVHDRCON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/BAPIOBDLVHDRCON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/BAPIOBDLVHDRCON INTO WA_/SCWM/BAPIOBDLVHDRCON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/BAPIOBDLVHDRCON-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BAPIOBDLVHDRCON-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/BAPIOBDLVHDRCON-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BAPIOBDLVHDRCON-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/BAPIOBDLVHDRCON-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BAPIOBDLVHDRCON-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/BAPIOBDLVHDRCON_STR,
DELIV_NUMB TYPE STRING,
GROSS_WT TYPE STRING,
NET_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
DOOR TYPE STRING,
INCOTERMS1 TYPE STRING,
INCOTERMS2 TYPE STRING,
ROUTE TYPE STRING,
SHIP_COND TYPE STRING,
DLV_PRIO TYPE STRING,
UNLOAD_PT TYPE STRING,
DLV_BLOCK TYPE STRING,
BILLOFLADING TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/BAPIOBDLVHDRCON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-DELIV_NUMB sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-GROSS_WT sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-NET_WEIGHT sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-UNIT_OF_WT sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-UNIT_OF_WT_ISO sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-VOLUME sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-VOLUMEUNIT sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-VOLUMEUNIT_ISO sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-DOOR sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-INCOTERMS1 sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-INCOTERMS2 sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-ROUTE sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-SHIP_COND sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-DLV_PRIO sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-UNLOAD_PT sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-DLV_BLOCK sy-vline
WA_/SCWM/BAPIOBDLVHDRCON_STR-BILLOFLADING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.