ABAP Select data from SAP table /SCMTMS/S_UI_PLN_TORFU_ROOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_UI_PLN_TORFU_ROOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_UI_PLN_TORFU_ROOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_UI_PLN_TORFU_ROOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_UI_PLN_TORFU_ROOT TYPE STANDARD TABLE OF /SCMTMS/S_UI_PLN_TORFU_ROOT,
      WA_/SCMTMS/S_UI_PLN_TORFU_ROOT TYPE /SCMTMS/S_UI_PLN_TORFU_ROOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_UI_PLN_TORFU_ROOT> TYPE /SCMTMS/S_UI_PLN_TORFU_ROOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_UI_PLN_TORFU_ROOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_UI_PLN_TORFU_ROOT
  INTO TABLE IT_/SCMTMS/S_UI_PLN_TORFU_ROOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_UI_PLN_TORFU_ROOT
*  INTO TABLE @DATA(IT_/SCMTMS/S_UI_PLN_TORFU_ROOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_UI_PLN_TORFU_ROOT INDEX 1 INTO DATA(WA_/SCMTMS/S_UI_PLN_TORFU_ROOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_UI_PLN_TORFU_ROOT ASSIGNING </SCMTMS/S_UI_PLN_TORFU_ROOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_UI_PLN_TORFU_ROOT>-KEY = 1.
</SCMTMS/S_UI_PLN_TORFU_ROOT>-TOR_ID = 1.
</SCMTMS/S_UI_PLN_TORFU_ROOT>-TOR_CAT = 1.
</SCMTMS/S_UI_PLN_TORFU_ROOT>-TOR_CAT_TXT = 1.
</SCMTMS/S_UI_PLN_TORFU_ROOT>-TOR_TYPE = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_UI_PLN_TORFU_ROOT INTO WA_/SCMTMS/S_UI_PLN_TORFU_ROOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TOR_TYPE_TXT, sy-vline,
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-LABELTXT, sy-vline,
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-RESP_PERSON, sy-vline,
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PARTNER_REF_ID, sy-vline,
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BL_NUMBER, sy-vline,
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PARTNER_MBL_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_UI_PLN_TORFU_ROOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_UI_PLN_TORFU_ROOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_UI_PLN_TORFU_ROOT INTO WA_/SCMTMS/S_UI_PLN_TORFU_ROOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TOR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TOR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TOR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSPID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TSPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SHIPPERID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-SHIPPERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-SHIPPERID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONSIGNEEID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CONSIGNEEID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CONSIGNEEID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRQ_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TRQ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TRQ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASE_BTD_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_BTD_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_BTD_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASE_BTD_ID_DLV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_BTD_ID_DLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_BTD_ID_DLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRN, internal->external for field TOT_DURATION CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TOT_DURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-TOT_DURATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID001, internal->external for field DSO_CARRIER_KEY CALL FUNCTION 'CONVERSION_EXIT_ID001_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-DSO_CARRIER_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-DSO_CARRIER_KEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DSO_CARRIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-DSO_CARRIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-DSO_CARRIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STOP_ID_F CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-STOP_ID_F IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-STOP_ID_F.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field LOG_LOC_UUID_F CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-LOG_LOC_UUID_F IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-LOG_LOC_UUID_F.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field ADR_LOC_UUID_F CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-ADR_LOC_UUID_F IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-ADR_LOC_UUID_F.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STOP_ID_L CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-STOP_ID_L IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-STOP_ID_L.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field LOG_LOC_UUID_L CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-LOG_LOC_UUID_L IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-LOG_LOC_UUID_L.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field ADR_LOC_UUID_L CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-ADR_LOC_UUID_L IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-ADR_LOC_UUID_L.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-GRO_WEI_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-GRO_WEI_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-GRO_VOL_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-GRO_VOL_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-NET_WEI_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-NET_WEI_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-QUA_PCS_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-QUA_PCS_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-QUA_PCS2_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-QUA_PCS2_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_UOM_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-BASE_UOM_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PKGUN_WEI_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PKGUN_WEI_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CONT_CNT_UNI_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-CONT_CNT_UNI_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUOM_I CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-MEASUOM_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-MEASUOM_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field INC_LOC_KEY_I CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-INC_LOC_KEY_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-INC_LOC_KEY_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCT_ID_I CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PRODUCT_ID_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-PRODUCT_ID_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SCH_ID_I CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-SCH_ID_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_PLN_TORFU_ROOT-SCH_ID_I.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR,
KEY TYPE STRING,
TOR_ID TYPE STRING,
TOR_CAT TYPE STRING,
TOR_CAT_TXT TYPE STRING,
TOR_TYPE TYPE STRING,
TOR_TYPE_TXT TYPE STRING,
LABELTXT TYPE STRING,
RESP_PERSON TYPE STRING,
PARTNER_REF_ID TYPE STRING,
BL_NUMBER TYPE STRING,
PARTNER_MBL_ID TYPE STRING,
DGO_INDICATOR TYPE STRING,
DGO_CHECK_ERROR TYPE STRING,
DGO_CHECK_ERROR_TXT TYPE STRING,
DGO_ICON TYPE STRING,
DGO_TOOLTIP TYPE STRING,
FIXATION TYPE STRING,
FIXATION_ICON TYPE STRING,
FIXATION_TOOLTIP TYPE STRING,
AUTO_PLAN TYPE STRING,
AUTO_PLAN_TXT TYPE STRING,
TRANSSRVLVL_CODE TYPE STRING,
TSPID TYPE STRING,
SCAC TYPE STRING,
TSP_DESCRIPTION TYPE STRING,
TSP_AIRLC TYPE STRING,
SHIPPERID TYPE STRING,
CONSIGNEEID TYPE STRING,
ERP_SHP_REL TYPE STRING,
ERP_SHP_REL_TXT TYPE STRING,
FINAL_EXEC_EVENT TYPE STRING,
ARCHIVING TYPE STRING,
ARCHIVING_TXT TYPE STRING,
BLK_PLAN TYPE STRING,
BLK_EXEC TYPE STRING,
BRC_PLAN TYPE STRING,
BRC_EXEC TYPE STRING,
PREDEC_BLK_PLAN TYPE STRING,
PREDEC_BLK_EXEC TYPE STRING,
DATETIME_BLK_PLA TYPE STRING,
USER_ID_BLK_PLAN TYPE STRING,
DATETIME_BLK_EXE TYPE STRING,
USER_ID_BLK_EXEC TYPE STRING,
LIFECYCLE TYPE STRING,
LIFECYCLE_TXT TYPE STRING,
BLOCK_REASON TYPE STRING,
BLOCK_REASON_TXT TYPE STRING,
CUSTOMS TYPE STRING,
CUSTOMS_TXT TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
CREATED_ON_TTT TYPE STRING,
CHANGED_ON_TTT TYPE STRING,
EXEC_ORG_ID TYPE STRING,
EXEC_GRP_ID TYPE STRING,
TRQ_IDENTIFIER TYPE STRING,
TRQ_KEY TYPE STRING,
TRQ_ID TYPE STRING,
TRQ_CAT TYPE STRING,
BASE_BTD_TCO TYPE STRING,
BASE_BTD_ID TYPE STRING,
BASE_BTD_TCO_DLV TYPE STRING,
BASE_BTD_ID_DLV TYPE STRING,
FO_IDENTIFIER TYPE STRING,
VOYAGE_IDENTIFIER TYPE STRING,
TOT_DISTANCE_KM TYPE STRING,
TOT_DURATION TYPE STRING,
DSO_CARRIER_KEY TYPE STRING,
DSO_CARRIER TYPE STRING,
DSO_SERVICE_LEVEL TYPE STRING,
DSO_AMOUNT TYPE STRING,
DSO_CURRENCY TYPE STRING,
DENSITY_FACTOR TYPE STRING,
DENSITY_FACTOR_TXT TYPE STRING,
SHIPPING_TYPE TYPE STRING,
SHIPPING_TYPE_TXT TYPE STRING,
GEN_SECURITY_STATUS TYPE STRING,
GEN_SECURITY_STATUS_TXT TYPE STRING,
CONSOL_TYPE TYPE STRING,
CONSOL_TYPE_TXT TYPE STRING,
CONS_IND TYPE STRING,
CONS_IND_TXT TYPE STRING,
EEW_TOR_ROOT TYPE STRING,
LMD_DRV_EXECUTION_TYPE TYPE STRING,
LMD_TSV_RESOURCE TYPE STRING,
KEY_F TYPE STRING,
STOP_ID_F TYPE STRING,
STOP_CAT_F TYPE STRING,
LOG_LOC_UUID_F TYPE STRING,
LOG_LOCID_F TYPE STRING,
LOG_LOCUN_F TYPE STRING,
LOG_LOCIATA_F TYPE STRING,
ADR_LOC_UUID_F TYPE STRING,
STOP_PARENT_KEY_F TYPE STRING,
STOP_WITH_SUBSTOPS_F TYPE STRING,
SUBSTOPS_KIND_F TYPE STRING,
NODE_HAS_ERROR_F TYPE STRING,
ACC_START_F TYPE STRING,
REQ_START_F TYPE STRING,
REQ_END_F TYPE STRING,
ACC_END_F TYPE STRING,
DATES_SETBY_F TYPE STRING,
PLAN_TRANS_TIME_F TYPE STRING,
STOP_ROLE_F TYPE STRING,
STOP_ORIGIN_F TYPE STRING,
STOP_SEQ_POS_F TYPE STRING,
STOP_CURRENT_F TYPE STRING,
AUTO_PLAN_F TYPE STRING,
SEL_TIME_F TYPE STRING,
APPOINTMENT_START_F TYPE STRING,
APPOINTMENT_END_F TYPE STRING,
CARR_CONF_START_F TYPE STRING,
CARR_CONF_END_F TYPE STRING,
PREPARE_START_F TYPE STRING,
PREPARE_END_F TYPE STRING,
FINALIZE_START_F TYPE STRING,
FINALIZE_END_F TYPE STRING,
PUDLV_CALC_BASE_F TYPE STRING,
STOP_FIX_F TYPE STRING,
HANDLING_EXEC_F TYPE STRING,
AGGR_ASSGN_START_L_F TYPE STRING,
AGGR_ASSGN_END_L_F TYPE STRING,
AGGR_ASSGN_START_C_F TYPE STRING,
AGGR_ASSGN_END_C_F TYPE STRING,
CUTOFF_CARGO_F TYPE STRING,
CUTOFF_DOC_F TYPE STRING,
CUTOFF_CUST_DOC_F TYPE STRING,
CUTOFF_DG_DOC_F TYPE STRING,
CUTOFF_DOC_SET_BY_SRVC_F TYPE STRING,
CUTOFF_CARR_VGM_F TYPE STRING,
ENTRY_PORT_F TYPE STRING,
EXIT_PORT_F TYPE STRING,
EWM_INT_REL_F TYPE STRING,
WH_TRANSM_STATUS_F TYPE STRING,
LOAD_PLAN_STATUS_F TYPE STRING,
WH_NEXT_REL_F TYPE STRING,
LOAD_POINT_ID_F TYPE STRING,
LOAD_POINT_UUID_F TYPE STRING,
ASR_INDICATOR_F TYPE STRING,
ASR_SOURCE_F TYPE STRING,
WH_CAT_F TYPE STRING,
WH_NUMBER_F TYPE STRING,
WH_DOOR_F TYPE STRING,
WH_DOOR_STATUS_F TYPE STRING,
BLK_EXEC_F TYPE STRING,
PREDEC_BLK_EXEC_F TYPE STRING,
LOG_LOC_ID_F TYPE STRING,
ADR_LOC_ID_F TYPE STRING,
ACC_START_D_F TYPE STRING,
ACC_START_T_F TYPE STRING,
ACC_START_TZ_F TYPE STRING,
REQ_START_D_F TYPE STRING,
REQ_START_T_F TYPE STRING,
REQ_START_TZ_F TYPE STRING,
REQ_END_D_F TYPE STRING,
REQ_END_T_F TYPE STRING,
REQ_END_TZ_F TYPE STRING,
ACC_END_D_F TYPE STRING,
ACC_END_T_F TYPE STRING,
ACC_END_TZ_F TYPE STRING,
ASSGN_START_D_F TYPE STRING,
ASSGN_START_T_F TYPE STRING,
ASSGN_START_TZ_F TYPE STRING,
ASSGN_END_D_F TYPE STRING,
ASSGN_END_T_F TYPE STRING,
ASSGN_END_TZ_F TYPE STRING,
PLAN_TRANS_TIME_D_F TYPE STRING,
PLAN_TRANS_TIME_T_F TYPE STRING,
PLAN_TRANS_TIME_TZ_F TYPE STRING,
SEL_TIME_D_F TYPE STRING,
SEL_TIME_T_F TYPE STRING,
SEL_TIME_TZ_F TYPE STRING,
FORMT_ADDRESS_F TYPE STRING,
FORMT_POSTAL_ADDR_F TYPE STRING,
FORMT_NAME_CITY_F TYPE STRING,
FORMT_FIRSTLN_F TYPE STRING,
FORMT_SECONDLN_F TYPE STRING,
FORMT_THIRDLN_F TYPE STRING,
FORMT_FOURTHLN_F TYPE STRING,
COUNTRY_CODE_A_F TYPE STRING,
REGION_A_F TYPE STRING,
CITY_NAME_A_F TYPE STRING,
STREET_POSTAL_CODE_A_F TYPE STRING,
STREET_NAME_A_F TYPE STRING,
HOUSE_ID_A_F TYPE STRING,
EEW_BO_LOC_ADRDET_A_F TYPE STRING,
COUNTRY_CODE_TXT_A_F TYPE STRING,
REGION_TXT_A_F TYPE STRING,
LOC_DESCRIPTION_F TYPE STRING,
KEY_L TYPE STRING,
STOP_ID_L TYPE STRING,
STOP_CAT_L TYPE STRING,
LOG_LOC_UUID_L TYPE STRING,
LOG_LOCID_L TYPE STRING,
LOG_LOCUN_L TYPE STRING,
LOG_LOCIATA_L TYPE STRING,
ADR_LOC_UUID_L TYPE STRING,
STOP_PARENT_KEY_L TYPE STRING,
STOP_WITH_SUBSTOPS_L TYPE STRING,
SUBSTOPS_KIND_L TYPE STRING,
NODE_HAS_ERROR_L TYPE STRING,
ACC_START_L TYPE STRING,
REQ_START_L TYPE STRING,
REQ_END_L TYPE STRING,
ACC_END_L TYPE STRING,
DATES_SETBY_L TYPE STRING,
PLAN_TRANS_TIME_L TYPE STRING,
STOP_ROLE_L TYPE STRING,
STOP_ORIGIN_L TYPE STRING,
STOP_SEQ_POS_L TYPE STRING,
STOP_CURRENT_L TYPE STRING,
AUTO_PLAN_L TYPE STRING,
SEL_TIME_L TYPE STRING,
APPOINTMENT_START_L TYPE STRING,
APPOINTMENT_END_L TYPE STRING,
CARR_CONF_START_L TYPE STRING,
CARR_CONF_END_L TYPE STRING,
PREPARE_START_L TYPE STRING,
PREPARE_END_L TYPE STRING,
FINALIZE_START_L TYPE STRING,
FINALIZE_END_L TYPE STRING,
PUDLV_CALC_BASE_L TYPE STRING,
STOP_FIX_L TYPE STRING,
HANDLING_EXEC_L TYPE STRING,
AGGR_ASSGN_START_L_L TYPE STRING,
AGGR_ASSGN_END_L_L TYPE STRING,
AGGR_ASSGN_START_C_L TYPE STRING,
AGGR_ASSGN_END_C_L TYPE STRING,
CUTOFF_CARGO_L TYPE STRING,
CUTOFF_DOC_L TYPE STRING,
CUTOFF_CUST_DOC_L TYPE STRING,
CUTOFF_DG_DOC_L TYPE STRING,
CUTOFF_DOC_SET_BY_SRVC_L TYPE STRING,
CUTOFF_CARR_VGM_L TYPE STRING,
ENTRY_PORT_L TYPE STRING,
EXIT_PORT_L TYPE STRING,
EWM_INT_REL_L TYPE STRING,
WH_TRANSM_STATUS_L TYPE STRING,
LOAD_PLAN_STATUS_L TYPE STRING,
WH_NEXT_REL_L TYPE STRING,
LOAD_POINT_ID_L TYPE STRING,
LOAD_POINT_UUID_L TYPE STRING,
ASR_INDICATOR_L TYPE STRING,
ASR_SOURCE_L TYPE STRING,
WH_CAT_L TYPE STRING,
WH_NUMBER_L TYPE STRING,
WH_DOOR_L TYPE STRING,
WH_DOOR_STATUS_L TYPE STRING,
BLK_EXEC_L TYPE STRING,
PREDEC_BLK_EXEC_L TYPE STRING,
LOG_LOC_ID_L TYPE STRING,
ADR_LOC_ID_L TYPE STRING,
ACC_START_D_L TYPE STRING,
ACC_START_T_L TYPE STRING,
ACC_START_TZ_L TYPE STRING,
REQ_START_D_L TYPE STRING,
REQ_START_T_L TYPE STRING,
REQ_START_TZ_L TYPE STRING,
REQ_END_D_L TYPE STRING,
REQ_END_T_L TYPE STRING,
REQ_END_TZ_L TYPE STRING,
ACC_END_D_L TYPE STRING,
ACC_END_T_L TYPE STRING,
ACC_END_TZ_L TYPE STRING,
ASSGN_START_D_L TYPE STRING,
ASSGN_START_T_L TYPE STRING,
ASSGN_START_TZ_L TYPE STRING,
ASSGN_END_D_L TYPE STRING,
ASSGN_END_T_L TYPE STRING,
ASSGN_END_TZ_L TYPE STRING,
PLAN_TRANS_TIME_D_L TYPE STRING,
PLAN_TRANS_TIME_T_L TYPE STRING,
PLAN_TRANS_TIME_TZ_L TYPE STRING,
SEL_TIME_D_L TYPE STRING,
SEL_TIME_T_L TYPE STRING,
SEL_TIME_TZ_L TYPE STRING,
FORMT_ADDRESS_L TYPE STRING,
FORMT_POSTAL_ADDR_L TYPE STRING,
FORMT_NAME_CITY_L TYPE STRING,
FORMT_FIRSTLN_L TYPE STRING,
FORMT_SECONDLN_L TYPE STRING,
FORMT_THIRDLN_L TYPE STRING,
FORMT_FOURTHLN_L TYPE STRING,
COUNTRY_CODE_A_L TYPE STRING,
REGION_A_L TYPE STRING,
CITY_NAME_A_L TYPE STRING,
STREET_POSTAL_CODE_A_L TYPE STRING,
STREET_NAME_A_L TYPE STRING,
HOUSE_ID_A_L TYPE STRING,
EEW_BO_LOC_ADRDET_A_L TYPE STRING,
COUNTRY_CODE_TXT_A_L TYPE STRING,
REGION_TXT_A_L TYPE STRING,
LOC_DESCRIPTION_L TYPE STRING,
KEY_I TYPE STRING,
MTR_I TYPE STRING,
GRO_WEI_VAL_I TYPE STRING,
GRO_WEI_UNI_I TYPE STRING,
GRO_VOL_VAL_I TYPE STRING,
GRO_VOL_UNI_I TYPE STRING,
NET_WEI_VAL_I TYPE STRING,
NET_WEI_UNI_I TYPE STRING,
QUA_PCS_VAL_I TYPE STRING,
QUA_PCS_UNI_I TYPE STRING,
QUA_PCS2_VAL_I TYPE STRING,
QUA_PCS2_UNI_I TYPE STRING,
BASE_UOM_VAL_I TYPE STRING,
BASE_UOM_UNI_I TYPE STRING,
PKGUN_WEI_VAL_I TYPE STRING,
PKGUN_WEI_UNI_I TYPE STRING,
CONT_CNT_VAL_I TYPE STRING,
CONT_CNT_UNI_I TYPE STRING,
LENGTH_I TYPE STRING,
WIDTH_I TYPE STRING,
HEIGHT_I TYPE STRING,
MEASUOM_I TYPE STRING,
AMT_GDSV_VAL_I TYPE STRING,
AMT_GDSV_CUR_I TYPE STRING,
AMT_INSV_VAL_I TYPE STRING,
AMT_INSV_CUR_I TYPE STRING,
AMT_GDSVC_VAL_I TYPE STRING,
AMT_GDSVC_CUR_I TYPE STRING,
AMT_HVAL_CAR_IND_I TYPE STRING,
INC_CLASS_CODE_I TYPE STRING,
INC_TRANSF_LOC_N_I TYPE STRING,
INC_LOC_KEY_I TYPE STRING,
INC_LOC_ID_I TYPE STRING,
PRODUCT_ID_I TYPE STRING,
PRD_KEY_I TYPE STRING,
PRD_FRGHT_GRP_I TYPE STRING,
PRD_TRANSP_GRP_I TYPE STRING,
PRD_DGPROFL_I TYPE STRING,
PACKAGE_ID_I TYPE STRING,
PACKAGE_TCO_I TYPE STRING,
NON_STACKABLE_I TYPE STRING,
PACKCODE_I TYPE STRING,
PACKAGE_ID_EXT_I TYPE STRING,
PACKAGE_ID_SRC_I TYPE STRING,
PACK_MAT_CAT_I TYPE STRING,
EEW_TOR_ITM_TR_I TYPE STRING,
OVERDIM_CARGO_I TYPE STRING,
VOYAGE_ID_I TYPE STRING,
FLIGHT_CODE_I TYPE STRING,
VESSEL_ID_I TYPE STRING,
IMO_ID_I TYPE STRING,
PLATENUMBER_I TYPE STRING,
SCHED_KEY_I TYPE STRING,
SCH_ID_I TYPE STRING,
SCHED_DEP_I TYPE STRING,
SCHED_DEP_D_I TYPE STRING,
SCHED_DEP_T_I TYPE STRING,
SCHED_DEP_TZ_I TYPE STRING,
CARGO_ITEM_DESCR_I TYPE STRING,
CARGO_ITEM_CAT_ICON_I TYPE STRING,
CARGO_ITEM_CAT_TOOLTIP_I TYPE STRING,
CARGO_RECEIPT_I TYPE STRING,
CARGO_RECEIPT_TXT_I TYPE STRING,
TURES_TCO_I TYPE STRING,
TURES_CAT_I TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-KEY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOR_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOR_CAT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOR_CAT_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOR_TYPE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOR_TYPE_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LABELTXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-RESP_PERSON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PARTNER_REF_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BL_NUMBER sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PARTNER_MBL_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DGO_INDICATOR sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DGO_CHECK_ERROR sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DGO_CHECK_ERROR_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DGO_ICON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DGO_TOOLTIP sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FIXATION sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FIXATION_ICON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FIXATION_TOOLTIP sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AUTO_PLAN sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AUTO_PLAN_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TRANSSRVLVL_CODE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TSPID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCAC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TSP_DESCRIPTION sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TSP_AIRLC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SHIPPERID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONSIGNEEID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ERP_SHP_REL sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ERP_SHP_REL_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FINAL_EXEC_EVENT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ARCHIVING sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ARCHIVING_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLK_PLAN sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLK_EXEC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BRC_PLAN sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BRC_EXEC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREDEC_BLK_PLAN sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREDEC_BLK_EXEC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DATETIME_BLK_PLA sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-USER_ID_BLK_PLAN sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DATETIME_BLK_EXE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-USER_ID_BLK_EXEC sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LIFECYCLE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LIFECYCLE_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLOCK_REASON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLOCK_REASON_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUSTOMS sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUSTOMS_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CREATED_BY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CREATED_ON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CHANGED_BY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CHANGED_ON sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CREATED_ON_TTT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CHANGED_ON_TTT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EXEC_ORG_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EXEC_GRP_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TRQ_IDENTIFIER sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TRQ_KEY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TRQ_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TRQ_CAT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_BTD_TCO sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_BTD_ID sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_BTD_TCO_DLV sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_BTD_ID_DLV sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FO_IDENTIFIER sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-VOYAGE_IDENTIFIER sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOT_DISTANCE_KM sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TOT_DURATION sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DSO_CARRIER_KEY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DSO_CARRIER sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DSO_SERVICE_LEVEL sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DSO_AMOUNT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DSO_CURRENCY sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DENSITY_FACTOR sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DENSITY_FACTOR_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SHIPPING_TYPE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SHIPPING_TYPE_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GEN_SECURITY_STATUS sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GEN_SECURITY_STATUS_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONSOL_TYPE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONSOL_TYPE_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONS_IND sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONS_IND_TXT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EEW_TOR_ROOT sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LMD_DRV_EXECUTION_TYPE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LMD_TSV_RESOURCE sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-KEY_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_CAT_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOC_UUID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCUN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCIATA_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ADR_LOC_UUID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_PARENT_KEY_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_WITH_SUBSTOPS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SUBSTOPS_KIND_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-NODE_HAS_ERROR_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DATES_SETBY_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ROLE_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ORIGIN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_SEQ_POS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_CURRENT_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AUTO_PLAN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-APPOINTMENT_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-APPOINTMENT_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARR_CONF_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARR_CONF_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREPARE_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREPARE_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FINALIZE_START_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FINALIZE_END_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PUDLV_CALC_BASE_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_FIX_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-HANDLING_EXEC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_START_L_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_END_L_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_START_C_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_END_C_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CARGO_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DOC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CUST_DOC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DG_DOC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DOC_SET_BY_SRVC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CARR_VGM_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ENTRY_PORT_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EXIT_PORT_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EWM_INT_REL_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_TRANSM_STATUS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_PLAN_STATUS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_NEXT_REL_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_POINT_ID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_POINT_UUID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASR_INDICATOR_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASR_SOURCE_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_CAT_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_NUMBER_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_DOOR_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_DOOR_STATUS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLK_EXEC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREDEC_BLK_EXEC_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOC_ID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ADR_LOC_ID_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_D_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_T_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_TZ_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_ADDRESS_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_POSTAL_ADDR_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_NAME_CITY_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_FIRSTLN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_SECONDLN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_THIRDLN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_FOURTHLN_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-COUNTRY_CODE_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REGION_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CITY_NAME_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STREET_POSTAL_CODE_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STREET_NAME_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-HOUSE_ID_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EEW_BO_LOC_ADRDET_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-COUNTRY_CODE_TXT_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REGION_TXT_A_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOC_DESCRIPTION_F sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-KEY_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_CAT_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOC_UUID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCUN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOCIATA_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ADR_LOC_UUID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_PARENT_KEY_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_WITH_SUBSTOPS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SUBSTOPS_KIND_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-NODE_HAS_ERROR_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-DATES_SETBY_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ROLE_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_ORIGIN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_SEQ_POS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_CURRENT_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AUTO_PLAN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-APPOINTMENT_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-APPOINTMENT_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARR_CONF_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARR_CONF_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREPARE_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREPARE_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FINALIZE_START_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FINALIZE_END_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PUDLV_CALC_BASE_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STOP_FIX_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-HANDLING_EXEC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_START_L_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_END_L_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_START_C_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AGGR_ASSGN_END_C_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CARGO_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DOC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CUST_DOC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DG_DOC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_DOC_SET_BY_SRVC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CUTOFF_CARR_VGM_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ENTRY_PORT_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EXIT_PORT_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EWM_INT_REL_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_TRANSM_STATUS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_PLAN_STATUS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_NEXT_REL_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_POINT_ID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOAD_POINT_UUID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASR_INDICATOR_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASR_SOURCE_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_CAT_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_NUMBER_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_DOOR_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WH_DOOR_STATUS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BLK_EXEC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PREDEC_BLK_EXEC_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOG_LOC_ID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ADR_LOC_ID_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_START_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_START_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REQ_END_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ACC_END_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_START_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-ASSGN_END_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLAN_TRANS_TIME_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_D_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_T_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SEL_TIME_TZ_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_ADDRESS_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_POSTAL_ADDR_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_NAME_CITY_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_FIRSTLN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_SECONDLN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_THIRDLN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FORMT_FOURTHLN_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-COUNTRY_CODE_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REGION_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CITY_NAME_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STREET_POSTAL_CODE_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-STREET_NAME_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-HOUSE_ID_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EEW_BO_LOC_ADRDET_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-COUNTRY_CODE_TXT_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-REGION_TXT_A_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LOC_DESCRIPTION_L sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-KEY_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-MTR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GRO_WEI_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GRO_WEI_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GRO_VOL_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-GRO_VOL_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-NET_WEI_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-NET_WEI_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-QUA_PCS_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-QUA_PCS_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-QUA_PCS2_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-QUA_PCS2_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_UOM_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-BASE_UOM_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PKGUN_WEI_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PKGUN_WEI_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONT_CNT_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CONT_CNT_UNI_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-LENGTH_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-WIDTH_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-HEIGHT_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-MEASUOM_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_GDSV_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_GDSV_CUR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_INSV_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_INSV_CUR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_GDSVC_VAL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_GDSVC_CUR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-AMT_HVAL_CAR_IND_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-INC_CLASS_CODE_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-INC_TRANSF_LOC_N_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-INC_LOC_KEY_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-INC_LOC_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PRODUCT_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PRD_KEY_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PRD_FRGHT_GRP_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PRD_TRANSP_GRP_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PRD_DGPROFL_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACKAGE_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACKAGE_TCO_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-NON_STACKABLE_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACKCODE_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACKAGE_ID_EXT_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACKAGE_ID_SRC_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PACK_MAT_CAT_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-EEW_TOR_ITM_TR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-OVERDIM_CARGO_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-VOYAGE_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-FLIGHT_CODE_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-VESSEL_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-IMO_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-PLATENUMBER_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCHED_KEY_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCH_ID_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCHED_DEP_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCHED_DEP_D_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCHED_DEP_T_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-SCHED_DEP_TZ_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARGO_ITEM_DESCR_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARGO_ITEM_CAT_ICON_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARGO_ITEM_CAT_TOOLTIP_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARGO_RECEIPT_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-CARGO_RECEIPT_TXT_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TURES_TCO_I sy-vline
WA_/SCMTMS/S_UI_PLN_TORFU_ROOT_STR-TURES_CAT_I sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.