ABAP Select data from SAP table /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP TYPE STANDARD TABLE OF /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP,
      WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP TYPE /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_UI_BOOTSTRAP_FWA_TMP> TYPE /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP
  INTO TABLE IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_UI_BOOTSTRAP_FWA_TMP
*  INTO TABLE @DATA(IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP INDEX 1 INTO DATA(WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP ASSIGNING </SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>-FAGRMNTID044 = 1.
</SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>-FAGRMT_TMPL_ID = 1.
</SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>-SERVICE_PRODUCT = 1.
</SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>-FAGTYPEID103 = 1.
</SCMTMS/S_UI_BOOTSTRAP_FWA_TMP>-CATALOG_TYPE = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP INTO WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-FAGUSAGEID105, sy-vline,
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-SKIP_INITIAL_SCREEM, sy-vline,
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-REF_KEY, sy-vline,
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-REF_MODE, sy-vline,
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-MUTUAL, sy-vline,
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-MUL_PTY_ALLOWED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP INTO WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FAGRMNTID044 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-FAGRMNTID044 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-FAGRMNTID044.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FAGRMT_TMPL_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-FAGRMT_TMPL_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-FAGRMT_TMPL_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERVICE_PRODUCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-SERVICE_PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-SERVICE_PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSION_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-VERSION_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP-VERSION_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR,
FAGRMNTID044 TYPE STRING,
FAGRMT_TMPL_ID TYPE STRING,
SERVICE_PRODUCT TYPE STRING,
FAGTYPEID103 TYPE STRING,
CATALOG_TYPE TYPE STRING,
FAGUSAGEID105 TYPE STRING,
SKIP_INITIAL_SCREEM TYPE STRING,
REF_KEY TYPE STRING,
REF_MODE TYPE STRING,
MUTUAL TYPE STRING,
MUL_PTY_ALLOWED TYPE STRING,
VERSION_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-FAGRMNTID044 sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-FAGRMT_TMPL_ID sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-SERVICE_PRODUCT sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-FAGTYPEID103 sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-CATALOG_TYPE sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-FAGUSAGEID105 sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-SKIP_INITIAL_SCREEM sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-REF_KEY sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-REF_MODE sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-MUTUAL sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-MUL_PTY_ALLOWED sy-vline
WA_/SCMTMS/S_UI_BOOTSTRAP_FWA_TMP_STR-VERSION_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.