ABAP Select data from SAP table /SCMTMS/S_TCC_DISP_DELTA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_TCC_DISP_DELTA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_TCC_DISP_DELTA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_TCC_DISP_DELTA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_TCC_DISP_DELTA TYPE STANDARD TABLE OF /SCMTMS/S_TCC_DISP_DELTA,
      WA_/SCMTMS/S_TCC_DISP_DELTA TYPE /SCMTMS/S_TCC_DISP_DELTA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_TCC_DISP_DELTA> TYPE /SCMTMS/S_TCC_DISP_DELTA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_TCC_DISP_DELTA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_TCC_DISP_DELTA
  INTO TABLE IT_/SCMTMS/S_TCC_DISP_DELTA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_TCC_DISP_DELTA
*  INTO TABLE @DATA(IT_/SCMTMS/S_TCC_DISP_DELTA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_TCC_DISP_DELTA INDEX 1 INTO DATA(WA_/SCMTMS/S_TCC_DISP_DELTA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_TCC_DISP_DELTA ASSIGNING </SCMTMS/S_TCC_DISP_DELTA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_TCC_DISP_DELTA>-KEY = 1.
</SCMTMS/S_TCC_DISP_DELTA>-ROOT_KEY = 1.
</SCMTMS/S_TCC_DISP_DELTA>-LOGISTICAL_KEY = 1.
</SCMTMS/S_TCC_DISP_DELTA>-TCET084 = 1.
</SCMTMS/S_TCC_DISP_DELTA>-DISP_ATTR = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_TCC_DISP_DELTA INTO WA_/SCMTMS/S_TCC_DISP_DELTA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_VALUE, sy-vline,
WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_UNIT, sy-vline,
WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_VALUE, sy-vline,
WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_UNIT, sy-vline,
WA_/SCMTMS/S_TCC_DISP_DELTA-DISP_CAT, sy-vline,
WA_/SCMTMS/S_TCC_DISP_DELTA-IS_NEW, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_TCC_DISP_DELTA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_TCC_DISP_DELTA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_TCC_DISP_DELTA INTO WA_/SCMTMS/S_TCC_DISP_DELTA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit QTYRN, internal->external for field OLD_VALUE CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_VALUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_VALUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OLD_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NEW_VALUE CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_VALUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_VALUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NEW_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NEW_VALUE_DSRC CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_VALUE_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_VALUE_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NEW_UNIT_DSRC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_UNIT_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-NEW_UNIT_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field OLD_VALUE_DSRC CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_VALUE_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_VALUE_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OLD_UNIT_DSRC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_UNIT_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-OLD_UNIT_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CALC_REF_LINE_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-CALC_REF_LINE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-CALC_REF_LINE_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CALC_REF_TO_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-CALC_REF_TO_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-CALC_REF_TO_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LINE_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TCC_DISP_DELTA-LINE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TCC_DISP_DELTA-LINE_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_TCC_DISP_DELTA_STR,
KEY TYPE STRING,
ROOT_KEY TYPE STRING,
LOGISTICAL_KEY TYPE STRING,
TCET084 TYPE STRING,
DISP_ATTR TYPE STRING,
OLD_VALUE TYPE STRING,
OLD_UNIT TYPE STRING,
NEW_VALUE TYPE STRING,
NEW_UNIT TYPE STRING,
DISP_CAT TYPE STRING,
IS_NEW TYPE STRING,
CLCBAS_CD025_I TYPE STRING,
DISP_ITEM_SRC_KEY TYPE STRING,
DISP_ITEM_SRC_NODE_KEY TYPE STRING,
DISP_ITEM_SRC_BO_KEY TYPE STRING,
DISP_ITEM_SRC_ROOT_KEY TYPE STRING,
CHRG_DISP_ITM_HOST_KEY TYPE STRING,
DISP_ID TYPE STRING,
NODE_IDRB TYPE STRING,
KEYTIK TYPE STRING,
LOG_REF TYPE STRING,
OLD_AMT TYPE STRING,
OLD_CURR TYPE STRING,
NEW_AMT TYPE STRING,
NEW_CURR TYPE STRING,
NEW_AMT_DSRC TYPE STRING,
NEW_CURR_DSRC TYPE STRING,
NEW_VALUE_DSRC TYPE STRING,
NEW_UNIT_DSRC TYPE STRING,
MANUAL_ENTRY TYPE STRING,
NEW_AMT_CR TYPE STRING,
NEW_AMT_CURR_CR TYPE STRING,
CHANGED_ATTR TYPE STRING,
DOC_CAT TYPE STRING,
AGREEMENT_KEY TYPE STRING,
RATE_TABLE_KEY TYPE STRING,
CALC_SHEET_KEY TYPE STRING,
IS_DISPUTE_REL TYPE STRING,
OLD_VALUE_DSRC TYPE STRING,
OLD_UNIT_DSRC TYPE STRING,
IS_TAX TYPE STRING,
CALC_REF_LINE_NO TYPE STRING,
CALC_REF_TO_NO TYPE STRING,
LINE_NO TYPE STRING,
IS_REJECT TYPE STRING,
INVOICE_RELEVANCE TYPE STRING,
REF_ELEM_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_TCC_DISP_DELTA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-ROOT_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-LOGISTICAL_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-TCET084 sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ATTR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_VALUE sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_UNIT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_VALUE sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_UNIT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_CAT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-IS_NEW sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CLCBAS_CD025_I sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ITEM_SRC_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ITEM_SRC_NODE_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ITEM_SRC_BO_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ITEM_SRC_ROOT_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CHRG_DISP_ITM_HOST_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DISP_ID sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NODE_IDRB sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-KEYTIK sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-LOG_REF sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_AMT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_CURR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_AMT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_CURR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_AMT_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_CURR_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_VALUE_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_UNIT_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-MANUAL_ENTRY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_AMT_CR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-NEW_AMT_CURR_CR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CHANGED_ATTR sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-DOC_CAT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-AGREEMENT_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-RATE_TABLE_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CALC_SHEET_KEY sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-IS_DISPUTE_REL sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_VALUE_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-OLD_UNIT_DSRC sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-IS_TAX sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CALC_REF_LINE_NO sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-CALC_REF_TO_NO sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-LINE_NO sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-IS_REJECT sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-INVOICE_RELEVANCE sy-vline
WA_/SCMTMS/S_TCC_DISP_DELTA_STR-REF_ELEM_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.