ABAP Select data from SAP table /SCMTMS/S_TC_TACT_RATE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_TC_TACT_RATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_TC_TACT_RATE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_TC_TACT_RATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_TC_TACT_RATE TYPE STANDARD TABLE OF /SCMTMS/S_TC_TACT_RATE,
      WA_/SCMTMS/S_TC_TACT_RATE TYPE /SCMTMS/S_TC_TACT_RATE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_TC_TACT_RATE> TYPE /SCMTMS/S_TC_TACT_RATE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_TC_TACT_RATE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_TC_TACT_RATE
  INTO TABLE IT_/SCMTMS/S_TC_TACT_RATE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_TC_TACT_RATE
*  INTO TABLE @DATA(IT_/SCMTMS/S_TC_TACT_RATE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_TC_TACT_RATE INDEX 1 INTO DATA(WA_/SCMTMS/S_TC_TACT_RATE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_TC_TACT_RATE ASSIGNING </SCMTMS/S_TC_TACT_RATE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_TC_TACT_RATE>-CATEGORY = 1.
</SCMTMS/S_TC_TACT_RATE>-INTERNAL_USE = 1.
</SCMTMS/S_TC_TACT_RATE>-SRC_CITY = 1.
</SCMTMS/S_TC_TACT_RATE>-SRC_CITY_SAP = 1.
</SCMTMS/S_TC_TACT_RATE>-SRC_COUNTRY = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_TC_TACT_RATE INTO WA_/SCMTMS/S_TC_TACT_RATE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_TC_TACT_RATE-SRC_COUNTRY_SAP, sy-vline,
WA_/SCMTMS/S_TC_TACT_RATE-DST_CITY, sy-vline,
WA_/SCMTMS/S_TC_TACT_RATE-DST_CITY_SAP, sy-vline,
WA_/SCMTMS/S_TC_TACT_RATE-DST_COUNTRY, sy-vline,
WA_/SCMTMS/S_TC_TACT_RATE-DST_COUNTRY_SAP, sy-vline,
WA_/SCMTMS/S_TC_TACT_RATE-NOTE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_TC_TACT_RATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_TC_TACT_RATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_TC_TACT_RATE INTO WA_/SCMTMS/S_TC_TACT_RATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UOM_SAP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TC_TACT_RATE-UOM_SAP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TC_TACT_RATE-UOM_SAP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_TC_TACT_RATE_STR,
CATEGORY TYPE STRING,
INTERNAL_USE TYPE STRING,
SRC_CITY TYPE STRING,
SRC_CITY_SAP TYPE STRING,
SRC_COUNTRY TYPE STRING,
SRC_COUNTRY_SAP TYPE STRING,
DST_CITY TYPE STRING,
DST_CITY_SAP TYPE STRING,
DST_COUNTRY TYPE STRING,
DST_COUNTRY_SAP TYPE STRING,
NOTE TYPE STRING,
CARRIER TYPE STRING,
SCR_ITEM TYPE STRING,
SCR_ITEM_SAP TYPE STRING,
ULD_RATE_TYPE TYPE STRING,
ULD_CHARGE_CODE TYPE STRING,
WEIGHT TYPE STRING,
UOM TYPE STRING,
UOM_SAP TYPE STRING,
RATE TYPE STRING,
CURRENCY TYPE STRING,
CURRENCY_SAP TYPE STRING,
DECIMAL_PLACE TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
SOURCE TYPE STRING,
INTERNAL_USE_2 TYPE STRING,
MIN_RATE TYPE STRING,
MAX_RATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_TC_TACT_RATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-CATEGORY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-INTERNAL_USE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SRC_CITY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SRC_CITY_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SRC_COUNTRY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SRC_COUNTRY_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-DST_CITY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-DST_CITY_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-DST_COUNTRY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-DST_COUNTRY_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-NOTE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-CARRIER sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SCR_ITEM sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SCR_ITEM_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-ULD_RATE_TYPE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-ULD_CHARGE_CODE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-WEIGHT sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-UOM sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-UOM_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-RATE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-CURRENCY sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-CURRENCY_SAP sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-DECIMAL_PLACE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-VALID_FROM sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-VALID_TO sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-SOURCE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-INTERNAL_USE_2 sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-MIN_RATE sy-vline
WA_/SCMTMS/S_TC_TACT_RATE_STR-MAX_RATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.