ABAP Select data from SAP table /SCMTMS/S_SCHTY_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_SCHTY_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_SCHTY_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_SCHTY_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_SCHTY_DATA TYPE STANDARD TABLE OF /SCMTMS/S_SCHTY_DATA,
      WA_/SCMTMS/S_SCHTY_DATA TYPE /SCMTMS/S_SCHTY_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_SCHTY_DATA> TYPE /SCMTMS/S_SCHTY_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_SCHTY_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_SCHTY_DATA
  INTO TABLE IT_/SCMTMS/S_SCHTY_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_SCHTY_DATA
*  INTO TABLE @DATA(IT_/SCMTMS/S_SCHTY_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_SCHTY_DATA INDEX 1 INTO DATA(WA_/SCMTMS/S_SCHTY_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_SCHTY_DATA ASSIGNING </SCMTMS/S_SCHTY_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_SCHTY_DATA>-CAT = 1.
</SCMTMS/S_SCHTY_DATA>-MOT = 1.
</SCMTMS/S_SCHTY_DATA>-DEF_TYPE = 1.
</SCMTMS/S_SCHTY_DATA>-NR_RANGE = 1.
</SCMTMS/S_SCHTY_DATA>-NR_RANGE_VOY = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_SCHTY_DATA INTO WA_/SCMTMS/S_SCHTY_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_SCHTY_DATA-CUTOFF_REF_TYPE, sy-vline,
WA_/SCMTMS/S_SCHTY_DATA-AUTO_FILL_MODE, sy-vline,
WA_/SCMTMS/S_SCHTY_DATA-CHANGE_STRAT, sy-vline,
WA_/SCMTMS/S_SCHTY_DATA-DELETE_STRAT, sy-vline,
WA_/SCMTMS/S_SCHTY_DATA-TEMPLATE, sy-vline,
WA_/SCMTMS/S_SCHTY_DATA-TOR_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_SCHTY_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_SCHTY_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_SCHTY_DATA INTO WA_/SCMTMS/S_SCHTY_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DFLT_WEI_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-DFLT_WEI_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-DFLT_WEI_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DFLT_VOL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-DFLT_VOL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-DFLT_VOL_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DFLT_PCS_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-DFLT_PCS_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-DFLT_PCS_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DFLT_PCS2_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-DFLT_PCS2_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-DFLT_PCS2_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DFLT_NLQ_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-DFLT_NLQ_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-DFLT_NLQ_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_SCHTY_DATA-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_SCHTY_DATA-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_SCHTY_DATA_STR,
CAT TYPE STRING,
MOT TYPE STRING,
DEF_TYPE TYPE STRING,
NR_RANGE TYPE STRING,
NR_RANGE_VOY TYPE STRING,
CUTOFF_REF_TYPE TYPE STRING,
AUTO_FILL_MODE TYPE STRING,
CHANGE_STRAT TYPE STRING,
DELETE_STRAT TYPE STRING,
TEMPLATE TYPE STRING,
TOR_TYPE TYPE STRING,
ROUTE_MAND TYPE STRING,
DEF_ROUTE_USAGE_FU TYPE STRING,
DEF_ROUTE_USAGE_TU TYPE STRING,
DEF_ROUTE_USAGE_RU TYPE STRING,
DEF_ROUTE_USAGE_CU TYPE STRING,
DEF_ROUTE_USAGE_PU TYPE STRING,
REFERENCE TYPE STRING,
CONSOLIDATION TYPE STRING,
CONS_DIRECT TYPE STRING,
SKIP_SRC_GW TYPE STRING,
SKIP_DEST_GW TYPE STRING,
DFLT_UI_CONFIG TYPE STRING,
ORDER_IND TYPE STRING,
USE_CAPA TYPE STRING,
USE_COSTS TYPE STRING,
TAL_TYPE TYPE STRING,
DO_NOT_COPY_TSP TYPE STRING,
DFLT_WEI_UOM TYPE STRING,
DFLT_VOL_UOM TYPE STRING,
DFLT_PCS_UOM TYPE STRING,
DFLT_PCS2_UOM TYPE STRING,
DFLT_NLQ_UOM TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_SCHTY_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CAT sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-MOT sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_TYPE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-NR_RANGE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-NR_RANGE_VOY sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CUTOFF_REF_TYPE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-AUTO_FILL_MODE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CHANGE_STRAT sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DELETE_STRAT sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-TEMPLATE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-TOR_TYPE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-ROUTE_MAND sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_ROUTE_USAGE_FU sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_ROUTE_USAGE_TU sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_ROUTE_USAGE_RU sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_ROUTE_USAGE_CU sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DEF_ROUTE_USAGE_PU sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-REFERENCE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CONSOLIDATION sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CONS_DIRECT sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-SKIP_SRC_GW sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-SKIP_DEST_GW sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_UI_CONFIG sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-ORDER_IND sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-USE_CAPA sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-USE_COSTS sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-TAL_TYPE sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DO_NOT_COPY_TSP sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_WEI_UOM sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_VOL_UOM sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_PCS_UOM sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_PCS2_UOM sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-DFLT_NLQ_UOM sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CREATED_BY sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CREATED_ON sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CHANGED_BY sy-vline
WA_/SCMTMS/S_SCHTY_DATA_STR-CHANGED_ON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.