ABAP Select data from SAP table /SCMTMS/S_RFQ_ITEM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_RFQ_ITEM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_RFQ_ITEM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_RFQ_ITEM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_RFQ_ITEM TYPE STANDARD TABLE OF /SCMTMS/S_RFQ_ITEM,
      WA_/SCMTMS/S_RFQ_ITEM TYPE /SCMTMS/S_RFQ_ITEM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_RFQ_ITEM> TYPE /SCMTMS/S_RFQ_ITEM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_RFQ_ITEM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_RFQ_ITEM
  INTO TABLE IT_/SCMTMS/S_RFQ_ITEM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_RFQ_ITEM
*  INTO TABLE @DATA(IT_/SCMTMS/S_RFQ_ITEM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_RFQ_ITEM INDEX 1 INTO DATA(WA_/SCMTMS/S_RFQ_ITEM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_RFQ_ITEM ASSIGNING </SCMTMS/S_RFQ_ITEM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_RFQ_ITEM>-SOL_SPEND_DIMENSION = 1.
</SCMTMS/S_RFQ_ITEM>-MASTER_RFQ_ITEM_KEY = 1.
</SCMTMS/S_RFQ_ITEM>-RESP_SUBMIT = 1.
</SCMTMS/S_RFQ_ITEM>-RESPONDED = 1.
</SCMTMS/S_RFQ_ITEM>-RESP_STATUS_CODE = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_RFQ_ITEM INTO WA_/SCMTMS/S_RFQ_ITEM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_RFQ_ITEM-ITEM_EQUIP_GROUP, sy-vline,
WA_/SCMTMS/S_RFQ_ITEM-ITEM_EQUIP_TYPE, sy-vline,
WA_/SCMTMS/S_RFQ_ITEM-GRACE_PERIOD, sy-vline,
WA_/SCMTMS/S_RFQ_ITEM-CARRIER_NO, sy-vline,
WA_/SCMTMS/S_RFQ_ITEM-CARRIER_UUID, sy-vline,
WA_/SCMTMS/S_RFQ_ITEM-RFQ_ITEM_TYPE_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_RFQ_ITEM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_RFQ_ITEM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_RFQ_ITEM INTO WA_/SCMTMS/S_RFQ_ITEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CARRIER_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CARRIER_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CARRIER_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID001, internal->external for field CARRIER_UUID CALL FUNCTION 'CONVERSION_EXIT_ID001_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CARRIER_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CARRIER_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DISTANCE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-DISTANCE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-DISTANCE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUANTITY CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-QUANTITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-QUANTITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MIN_CAPACITY_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-MIN_CAPACITY_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-MIN_CAPACITY_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field MIN_CAPACITY CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-MIN_CAPACITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-MIN_CAPACITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CHARG_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CHARG_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CHARG_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CHARG_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CHARG_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CHARG_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_DISTANCE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_DISTANCE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_DISTANCE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_QUANTITY CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_QUANTITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_QUANTITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field RESP_CHARG_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_CHARG_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_CHARG_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RESP_CHARG_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-RESP_CHARG_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-RESP_CHARG_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_DISTANCE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_DISTANCE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_DISTANCE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_QUANTITY CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_QUANTITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_QUANTITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_CHARG_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_CHARG_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_CHARG_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_CHARG_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RFQ_ITEM-CNF_CHARG_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RFQ_ITEM-CNF_CHARG_WEI_UNI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_RFQ_ITEM_STR,
SOL_SPEND_DIMENSION TYPE STRING,
MASTER_RFQ_ITEM_KEY TYPE STRING,
RESP_SUBMIT TYPE STRING,
RESPONDED TYPE STRING,
RESP_STATUS_CODE TYPE STRING,
ITEM_EQUIP_GROUP TYPE STRING,
ITEM_EQUIP_TYPE TYPE STRING,
GRACE_PERIOD TYPE STRING,
CARRIER_NO TYPE STRING,
CARRIER_UUID TYPE STRING,
RFQ_ITEM_TYPE_CODE TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DISTANCE TYPE STRING,
DISTANCE_UOM TYPE STRING,
PERIODICITY TYPE STRING,
PRIORITY TYPE STRING,
DIMENSION TYPE STRING,
QUANTITY TYPE STRING,
MIN_CAPACITY_UOM TYPE STRING,
UOM TYPE STRING,
BUDGET TYPE STRING,
BUDGET_CURRENCY TYPE STRING,
MTR TYPE STRING,
REVENUE TYPE STRING,
MIN_CAPACITY TYPE STRING,
REVENUE_CURRENCY TYPE STRING,
CHARG_WEI_VAL TYPE STRING,
CHARG_WEI_UNI TYPE STRING,
AWARD_CONFIRM TYPE STRING,
AWARD_CONFIRM_REASON TYPE STRING,
OPT_AT_CAP_LINE TYPE STRING,
RESP_GRO_WEI_VAL TYPE STRING,
RESP_GRO_WEI_UNI TYPE STRING,
RESP_GRO_VOL_VAL TYPE STRING,
RESP_GRO_VOL_UNI TYPE STRING,
RESP_QUA_PCS_VAL TYPE STRING,
RESP_QUA_PCS_UNI TYPE STRING,
RESP_CONT_CNT_VAL TYPE STRING,
RESP_CONT_CNT_UNI TYPE STRING,
RESP_DISTANCE TYPE STRING,
RESP_DISTANCE_UOM TYPE STRING,
RESP_DIMENSION TYPE STRING,
RESP_QUANTITY TYPE STRING,
RESP_UOM TYPE STRING,
RESP_CHARG_WEI_VAL TYPE STRING,
RESP_CHARG_WEI_UNI TYPE STRING,
CNF_GRO_WEI_VAL TYPE STRING,
CNF_GRO_WEI_UNI TYPE STRING,
CNF_GRO_VOL_VAL TYPE STRING,
CNF_GRO_VOL_UNI TYPE STRING,
CNF_QUA_PCS_VAL TYPE STRING,
CNF_QUA_PCS_UNI TYPE STRING,
CNF_CONT_CNT_VAL TYPE STRING,
CNF_CONT_CNT_UNI TYPE STRING,
CNF_DISTANCE TYPE STRING,
CNF_DISTANCE_UOM TYPE STRING,
CNF_DIMENSION TYPE STRING,
CNF_QUANTITY TYPE STRING,
CNF_UOM TYPE STRING,
CNF_CHARG_WEI_VAL TYPE STRING,
CNF_CHARG_WEI_UNI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_RFQ_ITEM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-SOL_SPEND_DIMENSION sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-MASTER_RFQ_ITEM_KEY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_SUBMIT sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESPONDED sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_STATUS_CODE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-ITEM_EQUIP_GROUP sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-ITEM_EQUIP_TYPE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-GRACE_PERIOD sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CARRIER_NO sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CARRIER_UUID sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RFQ_ITEM_TYPE_CODE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-DISTANCE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-DISTANCE_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-PERIODICITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-PRIORITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-DIMENSION sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-QUANTITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-MIN_CAPACITY_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-BUDGET sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-BUDGET_CURRENCY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-MTR sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-REVENUE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-MIN_CAPACITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-REVENUE_CURRENCY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CHARG_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CHARG_WEI_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-AWARD_CONFIRM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-AWARD_CONFIRM_REASON sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-OPT_AT_CAP_LINE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_DISTANCE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_DISTANCE_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_DIMENSION sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_QUANTITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_CHARG_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-RESP_CHARG_WEI_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_DISTANCE sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_DISTANCE_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_DIMENSION sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_QUANTITY sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_UOM sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_CHARG_WEI_VAL sy-vline
WA_/SCMTMS/S_RFQ_ITEM_STR-CNF_CHARG_WEI_UNI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.