ABAP Select data from SAP table /SCMTMS/S_LSO_EX_CONTAINER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_LSO_EX_CONTAINER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_LSO_EX_CONTAINER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_LSO_EX_CONTAINER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_LSO_EX_CONTAINER TYPE STANDARD TABLE OF /SCMTMS/S_LSO_EX_CONTAINER,
      WA_/SCMTMS/S_LSO_EX_CONTAINER TYPE /SCMTMS/S_LSO_EX_CONTAINER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_LSO_EX_CONTAINER> TYPE /SCMTMS/S_LSO_EX_CONTAINER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_LSO_EX_CONTAINER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_LSO_EX_CONTAINER
  INTO TABLE IT_/SCMTMS/S_LSO_EX_CONTAINER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_LSO_EX_CONTAINER
*  INTO TABLE @DATA(IT_/SCMTMS/S_LSO_EX_CONTAINER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_LSO_EX_CONTAINER INDEX 1 INTO DATA(WA_/SCMTMS/S_LSO_EX_CONTAINER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_LSO_EX_CONTAINER ASSIGNING </SCMTMS/S_LSO_EX_CONTAINER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_LSO_EX_CONTAINER>-TURES_UUID = 1.
</SCMTMS/S_LSO_EX_CONTAINER>-TURES_ID = 1.
</SCMTMS/S_LSO_EX_CONTAINER>-EQUITYPE = 1.
</SCMTMS/S_LSO_EX_CONTAINER>-EQUISZTP = 1.
</SCMTMS/S_LSO_EX_CONTAINER>-PAYLOAD_WEIGHT = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_LSO_EX_CONTAINER INTO WA_/SCMTMS/S_LSO_EX_CONTAINER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_LSO_EX_CONTAINER-PAYLOAD_WGHT_UOM, sy-vline,
WA_/SCMTMS/S_LSO_EX_CONTAINER-CUBIC_CAPACITY, sy-vline,
WA_/SCMTMS/S_LSO_EX_CONTAINER-CUBIC_CAPA_UOM, sy-vline,
WA_/SCMTMS/S_LSO_EX_CONTAINER-INTERNAL_LENGTH, sy-vline,
WA_/SCMTMS/S_LSO_EX_CONTAINER-INTERNAL_WIDTH, sy-vline,
WA_/SCMTMS/S_LSO_EX_CONTAINER-INTERNAL_HEIGHT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_LSO_EX_CONTAINER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_LSO_EX_CONTAINER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_LSO_EX_CONTAINER INTO WA_/SCMTMS/S_LSO_EX_CONTAINER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field TURES_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-TURES_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-TURES_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PAYLOAD_WGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-PAYLOAD_WGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-PAYLOAD_WGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CUBIC_CAPA_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-CUBIC_CAPA_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-CUBIC_CAPA_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INTERNAL_LWH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-INTERNAL_LWH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-INTERNAL_LWH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUAN_UNITS_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-QUAN_UNITS_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-QUAN_UNITS_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALT_QUAN_UNITS_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-ALT_QUAN_UNITS_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-ALT_QUAN_UNITS_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_GROSS_WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-MAX_GROSS_WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-MAX_GROSS_WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TARE_WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-TARE_WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-TARE_WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TARE_VOLUME_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-TARE_VOLUME_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-TARE_VOLUME_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TEMP_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-TEMP_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-TEMP_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_LWH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-MAX_LWH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-MAX_LWH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field FIXED_COST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_LSO_EX_CONTAINER-FIXED_COST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_LSO_EX_CONTAINER-FIXED_COST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_LSO_EX_CONTAINER_STR,
TURES_UUID TYPE STRING,
TURES_ID TYPE STRING,
EQUITYPE TYPE STRING,
EQUISZTP TYPE STRING,
PAYLOAD_WEIGHT TYPE STRING,
PAYLOAD_WGHT_UOM TYPE STRING,
CUBIC_CAPACITY TYPE STRING,
CUBIC_CAPA_UOM TYPE STRING,
INTERNAL_LENGTH TYPE STRING,
INTERNAL_WIDTH TYPE STRING,
INTERNAL_HEIGHT TYPE STRING,
INTERNAL_LWH_UOM TYPE STRING,
QUAN_UNITS TYPE STRING,
QUAN_UNITS_UOM TYPE STRING,
ALT_QUAN_UNITS TYPE STRING,
ALT_QUAN_UNITS_UOM TYPE STRING,
MAX_GROSS_WEIGHT TYPE STRING,
MAX_GROSS_WEIGHT_UOM TYPE STRING,
TARE_WEIGHT TYPE STRING,
TARE_WEIGHT_UOM TYPE STRING,
TARE_VOLUME TYPE STRING,
TARE_VOLUME_UOM TYPE STRING,
TEMP_CONTROL TYPE STRING,
TEMP_CTRL_MIN TYPE STRING,
TEMP_CTRL_MAX TYPE STRING,
TEMP_UOM TYPE STRING,
VENTILATED TYPE STRING,
MAX_LENGTH TYPE STRING,
MAX_WIDTH TYPE STRING,
MAX_HEIGHT TYPE STRING,
MAX_LWH_UOM TYPE STRING,
FOOD_GRADE_IND TYPE STRING,
COUNT TYPE STRING,
FIXED_COST TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_LSO_EX_CONTAINER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TURES_UUID sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TURES_ID sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-EQUITYPE sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-EQUISZTP sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-PAYLOAD_WEIGHT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-PAYLOAD_WGHT_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-CUBIC_CAPACITY sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-CUBIC_CAPA_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-INTERNAL_LENGTH sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-INTERNAL_WIDTH sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-INTERNAL_HEIGHT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-INTERNAL_LWH_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-QUAN_UNITS sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-QUAN_UNITS_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-ALT_QUAN_UNITS sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-ALT_QUAN_UNITS_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_GROSS_WEIGHT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_GROSS_WEIGHT_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TARE_WEIGHT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TARE_WEIGHT_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TARE_VOLUME sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TARE_VOLUME_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TEMP_CONTROL sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TEMP_CTRL_MIN sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TEMP_CTRL_MAX sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-TEMP_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-VENTILATED sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_LENGTH sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_WIDTH sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_HEIGHT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-MAX_LWH_UOM sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-FOOD_GRADE_IND sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-COUNT sy-vline
WA_/SCMTMS/S_LSO_EX_CONTAINER_STR-FIXED_COST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.