ABAP Select data from SAP table /SCMTMS/S_INV_DISP_CHRG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_INV_DISP_CHRG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_INV_DISP_CHRG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_INV_DISP_CHRG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_INV_DISP_CHRG TYPE STANDARD TABLE OF /SCMTMS/S_INV_DISP_CHRG,
      WA_/SCMTMS/S_INV_DISP_CHRG TYPE /SCMTMS/S_INV_DISP_CHRG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_INV_DISP_CHRG> TYPE /SCMTMS/S_INV_DISP_CHRG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_INV_DISP_CHRG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_INV_DISP_CHRG
  INTO TABLE IT_/SCMTMS/S_INV_DISP_CHRG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_INV_DISP_CHRG
*  INTO TABLE @DATA(IT_/SCMTMS/S_INV_DISP_CHRG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_INV_DISP_CHRG INDEX 1 INTO DATA(WA_/SCMTMS/S_INV_DISP_CHRG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_INV_DISP_CHRG ASSIGNING </SCMTMS/S_INV_DISP_CHRG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_INV_DISP_CHRG>-NEW_VALUE = 1.
</SCMTMS/S_INV_DISP_CHRG>-NEW_UNIT = 1.
</SCMTMS/S_INV_DISP_CHRG>-DISP_ITEM_SRC_KEY = 1.
</SCMTMS/S_INV_DISP_CHRG>-DISP_ITEM_SRC_NODE_KEY = 1.
</SCMTMS/S_INV_DISP_CHRG>-DISP_ITEM_SRC_BO_KEY = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_INV_DISP_CHRG INTO WA_/SCMTMS/S_INV_DISP_CHRG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_INV_DISP_CHRG-DISP_ITEM_SRC_ROOT_KEY, sy-vline,
WA_/SCMTMS/S_INV_DISP_CHRG-CHRG_DISP_ITM_HOST_KEY, sy-vline,
WA_/SCMTMS/S_INV_DISP_CHRG-DISP_ID, sy-vline,
WA_/SCMTMS/S_INV_DISP_CHRG-NODE_IDRB, sy-vline,
WA_/SCMTMS/S_INV_DISP_CHRG-KEYTIK, sy-vline,
WA_/SCMTMS/S_INV_DISP_CHRG-TCET084, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_INV_DISP_CHRG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_INV_DISP_CHRG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_INV_DISP_CHRG INTO WA_/SCMTMS/S_INV_DISP_CHRG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit QTYRN, internal->external for field NEW_VALUE CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-NEW_VALUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-NEW_VALUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NEW_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-NEW_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-NEW_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NEW_VALUE_DSRC CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-NEW_VALUE_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-NEW_VALUE_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NEW_UNIT_DSRC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-NEW_UNIT_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-NEW_UNIT_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field OLD_VALUE_DSRC CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-OLD_VALUE_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-OLD_VALUE_DSRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OLD_UNIT_DSRC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_INV_DISP_CHRG-OLD_UNIT_DSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_INV_DISP_CHRG-OLD_UNIT_DSRC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_INV_DISP_CHRG_STR,
NEW_VALUE TYPE STRING,
NEW_UNIT TYPE STRING,
DISP_ITEM_SRC_KEY TYPE STRING,
DISP_ITEM_SRC_NODE_KEY TYPE STRING,
DISP_ITEM_SRC_BO_KEY TYPE STRING,
DISP_ITEM_SRC_ROOT_KEY TYPE STRING,
CHRG_DISP_ITM_HOST_KEY TYPE STRING,
DISP_ID TYPE STRING,
NODE_IDRB TYPE STRING,
KEYTIK TYPE STRING,
TCET084 TYPE STRING,
LOG_REF TYPE STRING,
OLD_AMT TYPE STRING,
OLD_CURR TYPE STRING,
NEW_AMT TYPE STRING,
NEW_CURR TYPE STRING,
NEW_AMT_DSRC TYPE STRING,
NEW_CURR_DSRC TYPE STRING,
NEW_VALUE_DSRC TYPE STRING,
NEW_UNIT_DSRC TYPE STRING,
NEW_AMT_CR TYPE STRING,
NEW_AMT_CURR_CR TYPE STRING,
OLD_AMT_DSRC TYPE STRING,
OLD_CURR_DSRC TYPE STRING,
OLD_VALUE_DSRC TYPE STRING,
OLD_UNIT_DSRC TYPE STRING,
SETL_NOT_RELEV TYPE STRING,
OLD_FINAL_AMT TYPE STRING,
OLD_FINAL_CURR TYPE STRING,
NEW_FINAL_AMT TYPE STRING,
NEW_FINAL_CURR TYPE STRING,
REF_ELEM_KEY TYPE STRING,
FIX_FINAL_AMT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_INV_DISP_CHRG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_VALUE sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_UNIT sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-DISP_ITEM_SRC_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-DISP_ITEM_SRC_NODE_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-DISP_ITEM_SRC_BO_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-DISP_ITEM_SRC_ROOT_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-CHRG_DISP_ITM_HOST_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-DISP_ID sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NODE_IDRB sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-KEYTIK sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-TCET084 sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-LOG_REF sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_AMT sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_CURR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_AMT sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_CURR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_AMT_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_CURR_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_VALUE_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_UNIT_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_AMT_CR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_AMT_CURR_CR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_AMT_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_CURR_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_VALUE_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_UNIT_DSRC sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-SETL_NOT_RELEV sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_FINAL_AMT sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-OLD_FINAL_CURR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_FINAL_AMT sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-NEW_FINAL_CURR sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-REF_ELEM_KEY sy-vline
WA_/SCMTMS/S_INV_DISP_CHRG_STR-FIX_FINAL_AMT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.