ABAP Select data from SAP table /SCMTMS/S_FUB_HARD_CONSTR_TRQ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_FUB_HARD_CONSTR_TRQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_FUB_HARD_CONSTR_TRQ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCMTMS/S_FUB_HARD_CONSTR_TRQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ TYPE STANDARD TABLE OF /SCMTMS/S_FUB_HARD_CONSTR_TRQ, WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ TYPE /SCMTMS/S_FUB_HARD_CONSTR_TRQ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCMTMS/S_FUB_HARD_CONSTR_TRQ> TYPE /SCMTMS/S_FUB_HARD_CONSTR_TRQ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_FUB_HARD_CONSTR_TRQ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCMTMS/S_FUB_HARD_CONSTR_TRQ INTO TABLE IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCMTMS/S_FUB_HARD_CONSTR_TRQ * INTO TABLE @DATA(IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ INDEX 1 INTO DATA(WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ ASSIGNING </SCMTMS/S_FUB_HARD_CONSTR_TRQ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_FUB_HARD_CONSTR_TRQ>-TSP_KEY = 1.
</SCMTMS/S_FUB_HARD_CONSTR_TRQ>-INC_CLASS_CODE = 1.
</SCMTMS/S_FUB_HARD_CONSTR_TRQ>-TRANSP_SERV_LEVEL_CODE = 1.
</SCMTMS/S_FUB_HARD_CONSTR_TRQ>-MOT = 1.
</SCMTMS/S_FUB_HARD_CONSTR_TRQ>-SHIPPING_TYPE = 1.
ENDLOOP. LOOP AT IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ INTO WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-DG_ADR_NO_EXEMPTION, sy-vline,
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-FUB_EMPTY_PROV_RET, sy-vline,
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-EMPTY_BY_ORD_PARTY, sy-vline,
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-DIRECT_EWM_ACTIVE, sy-vline,
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-BLOCK, sy-vline,
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-PUDL_SPECIFICATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_FUB_HARD_CONSTR_TRQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_FUB_HARD_CONSTR_TRQ INTO WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WM_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-WM_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-WM_LOGSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR,
TSP_KEY TYPE STRING,
INC_CLASS_CODE TYPE STRING,
TRANSP_SERV_LEVEL_CODE TYPE STRING,
MOT TYPE STRING,
SHIPPING_TYPE TYPE STRING,
DG_ADR_NO_EXEMPTION TYPE STRING,
FUB_EMPTY_PROV_RET TYPE STRING,
EMPTY_BY_ORD_PARTY TYPE STRING,
DIRECT_EWM_ACTIVE TYPE STRING,
BLOCK TYPE STRING,
PUDL_SPECIFICATION TYPE STRING,
LGLC_LIC_IND TYPE STRING,
WM_LOGSYS TYPE STRING,
WM_WH_NUMBER TYPE STRING,
WM_WH_CAT TYPE STRING,
LOGSYS TYPE STRING,
BASE_BTD_TCO TYPE STRING,
DLV_RETURN TYPE STRING,
DLV_FU_BTD_TCO TYPE STRING,
DT_ORD_COMB_IND TYPE STRING,
QTY_DTM_FIXED TYPE STRING,
PRD_TRANSP_GRP TYPE STRING,
STOP_STRING TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-TSP_KEY sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-INC_CLASS_CODE sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-TRANSP_SERV_LEVEL_CODE sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-MOT sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-SHIPPING_TYPE sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-DG_ADR_NO_EXEMPTION sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-FUB_EMPTY_PROV_RET sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-EMPTY_BY_ORD_PARTY sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-DIRECT_EWM_ACTIVE sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-BLOCK sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-PUDL_SPECIFICATION sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-LGLC_LIC_IND sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-WM_LOGSYS sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-WM_WH_NUMBER sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-WM_WH_CAT sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-LOGSYS sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-BASE_BTD_TCO sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-DLV_RETURN sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-DLV_FU_BTD_TCO sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-DT_ORD_COMB_IND sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-QTY_DTM_FIXED sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-PRD_TRANSP_GRP sy-vline
WA_/SCMTMS/S_FUB_HARD_CONSTR_TRQ_STR-STOP_STRING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.