ABAP Select data from SAP table /SCMTMS/S_BS_Q_RESULT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_BS_Q_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_BS_Q_RESULT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_BS_Q_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_BS_Q_RESULT TYPE STANDARD TABLE OF /SCMTMS/S_BS_Q_RESULT,
      WA_/SCMTMS/S_BS_Q_RESULT TYPE /SCMTMS/S_BS_Q_RESULT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_BS_Q_RESULT> TYPE /SCMTMS/S_BS_Q_RESULT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_BS_Q_RESULT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_BS_Q_RESULT
  INTO TABLE IT_/SCMTMS/S_BS_Q_RESULT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_BS_Q_RESULT
*  INTO TABLE @DATA(IT_/SCMTMS/S_BS_Q_RESULT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_BS_Q_RESULT INDEX 1 INTO DATA(WA_/SCMTMS/S_BS_Q_RESULT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_BS_Q_RESULT ASSIGNING </SCMTMS/S_BS_Q_RESULT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_BS_Q_RESULT>-DB_KEY = 1.
</SCMTMS/S_BS_Q_RESULT>-BS_ID = 1.
</SCMTMS/S_BS_Q_RESULT>-TDL_UUID = 1.
</SCMTMS/S_BS_Q_RESULT>-VALID_FROM_UTC = 1.
</SCMTMS/S_BS_Q_RESULT>-VALID_TO_UTC = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_BS_Q_RESULT INTO WA_/SCMTMS/S_BS_Q_RESULT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_BS_Q_RESULT-UNIT, sy-vline,
WA_/SCMTMS/S_BS_Q_RESULT-TOL_NEG, sy-vline,
WA_/SCMTMS/S_BS_Q_RESULT-TOL_POS, sy-vline,
WA_/SCMTMS/S_BS_Q_RESULT-EXCESS_PENCOST, sy-vline,
WA_/SCMTMS/S_BS_Q_RESULT-SHORTG_PENCOST, sy-vline,
WA_/SCMTMS/S_BS_Q_RESULT-CREATED_BY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_BS_Q_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_BS_Q_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_BS_Q_RESULT INTO WA_/SCMTMS/S_BS_Q_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BS_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-BS_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-BS_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TDLID, internal->external for field TDL_UUID CALL FUNCTION 'CONVERSION_EXIT_TDLID_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-TDL_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-TDL_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TDL_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_BS_Q_RESULT-TDL_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_BS_Q_RESULT-TDL_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_BS_Q_RESULT_STR,
DB_KEY TYPE STRING,
BS_ID TYPE STRING,
TDL_UUID TYPE STRING,
VALID_FROM_UTC TYPE STRING,
VALID_TO_UTC TYPE STRING,
UNIT TYPE STRING,
TOL_NEG TYPE STRING,
TOL_POS TYPE STRING,
EXCESS_PENCOST TYPE STRING,
SHORTG_PENCOST TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
TDL_ID TYPE STRING,
ORIENTATION TYPE STRING,
GEO_FR TYPE STRING,
GEO_FR_TYPE TYPE STRING,
GEO_TO TYPE STRING,
GEO_TO_TYPE TYPE STRING,
MTR TYPE STRING,
MOT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_BS_Q_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-DB_KEY sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-BS_ID sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-TDL_UUID sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-VALID_FROM_UTC sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-VALID_TO_UTC sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-UNIT sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-TOL_NEG sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-TOL_POS sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-EXCESS_PENCOST sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-SHORTG_PENCOST sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-CREATED_BY sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-CREATED_ON sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-CHANGED_BY sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-CHANGED_ON sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-TDL_ID sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-ORIENTATION sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-GEO_FR sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-GEO_FR_TYPE sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-GEO_TO sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-GEO_TO_TYPE sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-MTR sy-vline
WA_/SCMTMS/S_BS_Q_RESULT_STR-MOT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.