ABAP Select data from SAP table /SCMTMS/D_PLNXSO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/D_PLNXSO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/D_PLNXSO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/D_PLNXSO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/D_PLNXSO TYPE STANDARD TABLE OF /SCMTMS/D_PLNXSO,
      WA_/SCMTMS/D_PLNXSO TYPE /SCMTMS/D_PLNXSO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/D_PLNXSO> TYPE /SCMTMS/D_PLNXSO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/D_PLNXSO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/D_PLNXSO
  INTO TABLE IT_/SCMTMS/D_PLNXSO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/D_PLNXSO
*  INTO TABLE @DATA(IT_/SCMTMS/D_PLNXSO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/D_PLNXSO INDEX 1 INTO DATA(WA_/SCMTMS/D_PLNXSO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/D_PLNXSO ASSIGNING </SCMTMS/D_PLNXSO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/D_PLNXSO>-MANDT = 1.
</SCMTMS/D_PLNXSO>-DB_KEY = 1.
</SCMTMS/D_PLNXSO>-PARENT_KEY = 1.
</SCMTMS/D_PLNXSO>-SCH_UUID = 1.
</SCMTMS/D_PLNXSO>-SCH_ID = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/D_PLNXSO INTO WA_/SCMTMS/D_PLNXSO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/D_PLNXSO-TRM_ICON, sy-vline,
WA_/SCMTMS/D_PLNXSO-SCH_CAT, sy-vline,
WA_/SCMTMS/D_PLNXSO-SCH_TYPE, sy-vline,
WA_/SCMTMS/D_PLNXSO-TSP, sy-vline,
WA_/SCMTMS/D_PLNXSO-TSPID, sy-vline,
WA_/SCMTMS/D_PLNXSO-TSP_SCAC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/D_PLNXSO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/D_PLNXSO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/D_PLNXSO INTO WA_/SCMTMS/D_PLNXSO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field SCH_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-SCH_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-SCH_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SCH_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-SCH_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-SCH_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSPID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-TSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-TSPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP12, internal->external for field SCH_REF CALL FUNCTION 'CONVERSION_EXIT_EXP12_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-SCH_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-SCH_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NORMLOADCONSVAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-NORMLOADCONSVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-NORMLOADCONSVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NORMLOADCONSUNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-NORMLOADCONSUNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-NORMLOADCONSUNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXSO-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXSO-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/D_PLNXSO_STR,
MANDT TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
SCH_UUID TYPE STRING,
SCH_ID TYPE STRING,
TRM_ICON TYPE STRING,
SCH_CAT TYPE STRING,
SCH_TYPE TYPE STRING,
TSP TYPE STRING,
TSPID TYPE STRING,
TSP_SCAC TYPE STRING,
FLIGHT_CODE TYPE STRING,
SRC_TDR_NAME TYPE STRING,
DEST_TDR_NAME TYPE STRING,
SCH_REF TYPE STRING,
LOOP_ID TYPE STRING,
PRD_TRANSP_GRP TYPE STRING,
DGO_INDICATOR TYPE STRING,
SHIPPING_TYPE TYPE STRING,
VAL_FROM_DATE TYPE STRING,
VAL_TO_DATE TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
NORMLOADCONSVAL TYPE STRING,
NORMLOADCONSUNI TYPE STRING,
REFERENCE TYPE STRING,
CONSOLIDATION TYPE STRING,
CONS_DIRECT TYPE STRING,
SKIP_SRC_GW TYPE STRING,
SKIP_DEST_GW TYPE STRING,
MOT TYPE STRING,
NR_RANGE TYPE STRING,
ORDER_IND TYPE STRING,
CUTOFF_REF_TYPE TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EEW_PLN_EX_SCHRO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/D_PLNXSO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/D_PLNXSO_STR-MANDT sy-vline
WA_/SCMTMS/D_PLNXSO_STR-DB_KEY sy-vline
WA_/SCMTMS/D_PLNXSO_STR-PARENT_KEY sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SCH_UUID sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SCH_ID sy-vline
WA_/SCMTMS/D_PLNXSO_STR-TRM_ICON sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SCH_CAT sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SCH_TYPE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-TSP sy-vline
WA_/SCMTMS/D_PLNXSO_STR-TSPID sy-vline
WA_/SCMTMS/D_PLNXSO_STR-TSP_SCAC sy-vline
WA_/SCMTMS/D_PLNXSO_STR-FLIGHT_CODE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SRC_TDR_NAME sy-vline
WA_/SCMTMS/D_PLNXSO_STR-DEST_TDR_NAME sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SCH_REF sy-vline
WA_/SCMTMS/D_PLNXSO_STR-LOOP_ID sy-vline
WA_/SCMTMS/D_PLNXSO_STR-PRD_TRANSP_GRP sy-vline
WA_/SCMTMS/D_PLNXSO_STR-DGO_INDICATOR sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SHIPPING_TYPE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-VAL_FROM_DATE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-VAL_TO_DATE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-NORMLOADCONSVAL sy-vline
WA_/SCMTMS/D_PLNXSO_STR-NORMLOADCONSUNI sy-vline
WA_/SCMTMS/D_PLNXSO_STR-REFERENCE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CONSOLIDATION sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CONS_DIRECT sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SKIP_SRC_GW sy-vline
WA_/SCMTMS/D_PLNXSO_STR-SKIP_DEST_GW sy-vline
WA_/SCMTMS/D_PLNXSO_STR-MOT sy-vline
WA_/SCMTMS/D_PLNXSO_STR-NR_RANGE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-ORDER_IND sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CUTOFF_REF_TYPE sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CREATED_BY sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CREATED_ON sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CHANGED_BY sy-vline
WA_/SCMTMS/D_PLNXSO_STR-CHANGED_ON sy-vline
WA_/SCMTMS/D_PLNXSO_STR-EEW_PLN_EX_SCHRO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.