ABAP Select data from SAP table /SCMTMS/D_PLNXFR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/D_PLNXFR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/D_PLNXFR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/D_PLNXFR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/D_PLNXFR TYPE STANDARD TABLE OF /SCMTMS/D_PLNXFR,
      WA_/SCMTMS/D_PLNXFR TYPE /SCMTMS/D_PLNXFR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/D_PLNXFR> TYPE /SCMTMS/D_PLNXFR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/D_PLNXFR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/D_PLNXFR
  INTO TABLE IT_/SCMTMS/D_PLNXFR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/D_PLNXFR
*  INTO TABLE @DATA(IT_/SCMTMS/D_PLNXFR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/D_PLNXFR INDEX 1 INTO DATA(WA_/SCMTMS/D_PLNXFR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/D_PLNXFR ASSIGNING </SCMTMS/D_PLNXFR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/D_PLNXFR>-MANDT = 1.
</SCMTMS/D_PLNXFR>-DB_KEY = 1.
</SCMTMS/D_PLNXFR>-PARENT_KEY = 1.
</SCMTMS/D_PLNXFR>-SOL_ID = 1.
</SCMTMS/D_PLNXFR>-FOR_UUID = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/D_PLNXFR INTO WA_/SCMTMS/D_PLNXFR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/D_PLNXFR-FOR_ID, sy-vline,
WA_/SCMTMS/D_PLNXFR-CAT, sy-vline,
WA_/SCMTMS/D_PLNXFR-TYPE, sy-vline,
WA_/SCMTMS/D_PLNXFR-TU_CAT, sy-vline,
WA_/SCMTMS/D_PLNXFR-SOURCE_LOC, sy-vline,
WA_/SCMTMS/D_PLNXFR-TARGET_LOC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/D_PLNXFR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/D_PLNXFR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/D_PLNXFR INTO WA_/SCMTMS/D_PLNXFR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field FOR_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-FOR_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-FOR_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FOR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-FOR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-FOR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field SOURCE_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-SOURCE_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-SOURCE_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field TARGET_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-TARGET_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-TARGET_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID012, internal->external for field VEHICLE_UUID CALL FUNCTION 'CONVERSION_EXIT_ID012_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-VEHICLE_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-VEHICLE_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_PU_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-REQ_PU_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-REQ_PU_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_PU_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-REQ_PU_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-REQ_PU_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_PU_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-ACC_PU_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-ACC_PU_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_PU_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-ACC_PU_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-ACC_PU_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_DL_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-REQ_DL_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-REQ_DL_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_DL_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-REQ_DL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-REQ_DL_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_DL_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-ACC_DL_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-ACC_DL_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_DL_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-ACC_DL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-ACC_DL_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NORMLOADCONSVAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-NORMLOADCONSVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-NORMLOADCONSVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NORMLOADCONSUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-NORMLOADCONSUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-NORMLOADCONSUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field FIXEDCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-FIXEDCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-FIXEDCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field TIME CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-TIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field DIST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-DIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-DIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field DISTCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-DISTCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-DISTCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field CO2 CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-CO2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-CO2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field PRODCOSTDIST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-PRODCOSTDIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-PRODCOSTDIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field PRODCOSTPROD CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-PRODCOSTPROD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-PRODCOSTPROD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field CO2PRODCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-CO2PRODCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-CO2PRODCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field STOPOFF CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-STOPOFF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-STOPOFF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field LOADCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-LOADCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-LOADCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field MODECOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-MODECOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-MODECOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP08, internal->external for field EARLINESS CALL FUNCTION 'CONVERSION_EXIT_EXP08_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXFR-EARLINESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXFR-EARLINESS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/D_PLNXFR_STR,
MANDT TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
SOL_ID TYPE STRING,
FOR_UUID TYPE STRING,
FOR_ID TYPE STRING,
CAT TYPE STRING,
TYPE TYPE STRING,
TU_CAT TYPE STRING,
SOURCE_LOC TYPE STRING,
TARGET_LOC TYPE STRING,
MTR TYPE STRING,
VEHICLE_UUID TYPE STRING,
VEHICLE_ID TYPE STRING,
REQ_PU_FR TYPE STRING,
REQ_PU_TO TYPE STRING,
ACC_PU_FR TYPE STRING,
ACC_PU_TO TYPE STRING,
REQ_DL_FR TYPE STRING,
REQ_DL_TO TYPE STRING,
ACC_DL_FR TYPE STRING,
ACC_DL_TO TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
NORMLOADCONSVAL TYPE STRING,
NORMLOADCONSUOM TYPE STRING,
FIXEDCOST TYPE STRING,
TIME TYPE STRING,
DIST TYPE STRING,
DISTCOST TYPE STRING,
CO2 TYPE STRING,
PRODCOSTDIST TYPE STRING,
PRODCOSTPROD TYPE STRING,
CO2PRODCOST TYPE STRING,
STOPOFF TYPE STRING,
LOADCOST TYPE STRING,
MODECOST TYPE STRING,
EARLINESS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/D_PLNXFR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/D_PLNXFR_STR-MANDT sy-vline
WA_/SCMTMS/D_PLNXFR_STR-DB_KEY sy-vline
WA_/SCMTMS/D_PLNXFR_STR-PARENT_KEY sy-vline
WA_/SCMTMS/D_PLNXFR_STR-SOL_ID sy-vline
WA_/SCMTMS/D_PLNXFR_STR-FOR_UUID sy-vline
WA_/SCMTMS/D_PLNXFR_STR-FOR_ID sy-vline
WA_/SCMTMS/D_PLNXFR_STR-CAT sy-vline
WA_/SCMTMS/D_PLNXFR_STR-TYPE sy-vline
WA_/SCMTMS/D_PLNXFR_STR-TU_CAT sy-vline
WA_/SCMTMS/D_PLNXFR_STR-SOURCE_LOC sy-vline
WA_/SCMTMS/D_PLNXFR_STR-TARGET_LOC sy-vline
WA_/SCMTMS/D_PLNXFR_STR-MTR sy-vline
WA_/SCMTMS/D_PLNXFR_STR-VEHICLE_UUID sy-vline
WA_/SCMTMS/D_PLNXFR_STR-VEHICLE_ID sy-vline
WA_/SCMTMS/D_PLNXFR_STR-REQ_PU_FR sy-vline
WA_/SCMTMS/D_PLNXFR_STR-REQ_PU_TO sy-vline
WA_/SCMTMS/D_PLNXFR_STR-ACC_PU_FR sy-vline
WA_/SCMTMS/D_PLNXFR_STR-ACC_PU_TO sy-vline
WA_/SCMTMS/D_PLNXFR_STR-REQ_DL_FR sy-vline
WA_/SCMTMS/D_PLNXFR_STR-REQ_DL_TO sy-vline
WA_/SCMTMS/D_PLNXFR_STR-ACC_DL_FR sy-vline
WA_/SCMTMS/D_PLNXFR_STR-ACC_DL_TO sy-vline
WA_/SCMTMS/D_PLNXFR_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/D_PLNXFR_STR-NORMLOADCONSVAL sy-vline
WA_/SCMTMS/D_PLNXFR_STR-NORMLOADCONSUOM sy-vline
WA_/SCMTMS/D_PLNXFR_STR-FIXEDCOST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-TIME sy-vline
WA_/SCMTMS/D_PLNXFR_STR-DIST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-DISTCOST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-CO2 sy-vline
WA_/SCMTMS/D_PLNXFR_STR-PRODCOSTDIST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-PRODCOSTPROD sy-vline
WA_/SCMTMS/D_PLNXFR_STR-CO2PRODCOST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-STOPOFF sy-vline
WA_/SCMTMS/D_PLNXFR_STR-LOADCOST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-MODECOST sy-vline
WA_/SCMTMS/D_PLNXFR_STR-EARLINESS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.