ABAP Select data from SAP table /SCMB/MDL_TRTYPE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMB/MDL_TRTYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMB/MDL_TRTYPE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMB/MDL_TRTYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMB/MDL_TRTYPE TYPE STANDARD TABLE OF /SCMB/MDL_TRTYPE,
      WA_/SCMB/MDL_TRTYPE TYPE /SCMB/MDL_TRTYPE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMB/MDL_TRTYPE> TYPE /SCMB/MDL_TRTYPE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMB/MDL_TRTYPE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMB/MDL_TRTYPE
  INTO TABLE IT_/SCMB/MDL_TRTYPE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMB/MDL_TRTYPE
*  INTO TABLE @DATA(IT_/SCMB/MDL_TRTYPE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMB/MDL_TRTYPE INDEX 1 INTO DATA(WA_/SCMB/MDL_TRTYPE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMB/MDL_TRTYPE ASSIGNING </SCMB/MDL_TRTYPE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMB/MDL_TRTYPE>-TTYPE = 1.
</SCMB/MDL_TRTYPE>-TXT = 1.
</SCMB/MDL_TRTYPE>-MOTSCODE = 1.
</SCMB/MDL_TRTYPE>-TTYPE_PARENT = 1.
</SCMB/MDL_TRTYPE>-TRMODE = 1.
ENDLOOP.

LOOP AT IT_/SCMB/MDL_TRTYPE INTO WA_/SCMB/MDL_TRTYPE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMB/MDL_TRTYPE-LOAD_WEIGHT, sy-vline,
WA_/SCMB/MDL_TRTYPE-LOAD_UOM_WGT, sy-vline,
WA_/SCMB/MDL_TRTYPE-LOAD_VOLUME, sy-vline,
WA_/SCMB/MDL_TRTYPE-LOAD_UOM_VOL, sy-vline,
WA_/SCMB/MDL_TRTYPE-LOAD_LENGTH, sy-vline,
WA_/SCMB/MDL_TRTYPE-LOAD_WIDTH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMB/MDL_TRTYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMB/MDL_TRTYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMB/MDL_TRTYPE INTO WA_/SCMB/MDL_TRTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_WGT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMB/MDL_TRTYPE-LOAD_UOM_WGT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/MDL_TRTYPE-LOAD_UOM_WGT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_VOL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMB/MDL_TRTYPE-LOAD_UOM_VOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/MDL_TRTYPE-LOAD_UOM_VOL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_UOM_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMB/MDL_TRTYPE-LOAD_UOM_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/MDL_TRTYPE-LOAD_UOM_LWH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMB/MDL_TRTYPE_STR,
TTYPE TYPE STRING,
TXT TYPE STRING,
MOTSCODE TYPE STRING,
TTYPE_PARENT TYPE STRING,
TRMODE TYPE STRING,
LOAD_WEIGHT TYPE STRING,
LOAD_UOM_WGT TYPE STRING,
LOAD_VOLUME TYPE STRING,
LOAD_UOM_VOL TYPE STRING,
LOAD_LENGTH TYPE STRING,
LOAD_WIDTH TYPE STRING,
LOAD_HEIGHT TYPE STRING,
LOAD_UOM_LWH TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMB/MDL_TRTYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMB/MDL_TRTYPE_STR-TTYPE sy-vline
WA_/SCMB/MDL_TRTYPE_STR-TXT sy-vline
WA_/SCMB/MDL_TRTYPE_STR-MOTSCODE sy-vline
WA_/SCMB/MDL_TRTYPE_STR-TTYPE_PARENT sy-vline
WA_/SCMB/MDL_TRTYPE_STR-TRMODE sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_WEIGHT sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_UOM_WGT sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_VOLUME sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_UOM_VOL sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_LENGTH sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_WIDTH sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_HEIGHT sy-vline
WA_/SCMB/MDL_TRTYPE_STR-LOAD_UOM_LWH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.