ABAP Select data from SAP table /SCF/BARS_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCF/BARS_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCF/BARS_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCF/BARS_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCF/BARS_STR TYPE STANDARD TABLE OF /SCF/BARS_STR,
      WA_/SCF/BARS_STR TYPE /SCF/BARS_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCF/BARS_STR> TYPE /SCF/BARS_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCF/BARS_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCF/BARS_STR
  INTO TABLE IT_/SCF/BARS_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCF/BARS_STR
*  INTO TABLE @DATA(IT_/SCF/BARS_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCF/BARS_STR INDEX 1 INTO DATA(WA_/SCF/BARS_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCF/BARS_STR ASSIGNING </SCF/BARS_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCF/BARS_STR>-ROW_INDEX = 1.
</SCF/BARS_STR>-COL_INDEX = 1.
</SCF/BARS_STR>-BAR_VALUES = 1.
</SCF/BARS_STR>-MINLEVEL = 1.
</SCF/BARS_STR>-MAXLEVEL = 1.
ENDLOOP.

LOOP AT IT_/SCF/BARS_STR INTO WA_/SCF/BARS_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCF/BARS_STR-VALUE1, sy-vline,
WA_/SCF/BARS_STR-VALUE2, sy-vline,
WA_/SCF/BARS_STR-VALUE3, sy-vline,
WA_/SCF/BARS_STR-TOTAL, sy-vline,
WA_/SCF/BARS_STR-TOOLTIP1, sy-vline,
WA_/SCF/BARS_STR-TOOLTIP2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCF/BARS_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCF/BARS_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCF/BARS_STR INTO WA_/SCF/BARS_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCF/BARS_STR_STR,
ROW_INDEX TYPE STRING,
COL_INDEX TYPE STRING,
BAR_VALUES TYPE STRING,
MINLEVEL TYPE STRING,
MAXLEVEL TYPE STRING,
VALUE1 TYPE STRING,
VALUE2 TYPE STRING,
VALUE3 TYPE STRING,
TOTAL TYPE STRING,
TOOLTIP1 TYPE STRING,
TOOLTIP2 TYPE STRING,
TOOLTIP3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCF/BARS_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCF/BARS_STR_STR-ROW_INDEX sy-vline
WA_/SCF/BARS_STR_STR-COL_INDEX sy-vline
WA_/SCF/BARS_STR_STR-BAR_VALUES sy-vline
WA_/SCF/BARS_STR_STR-MINLEVEL sy-vline
WA_/SCF/BARS_STR_STR-MAXLEVEL sy-vline
WA_/SCF/BARS_STR_STR-VALUE1 sy-vline
WA_/SCF/BARS_STR_STR-VALUE2 sy-vline
WA_/SCF/BARS_STR_STR-VALUE3 sy-vline
WA_/SCF/BARS_STR_STR-TOTAL sy-vline
WA_/SCF/BARS_STR_STR-TOOLTIP1 sy-vline
WA_/SCF/BARS_STR_STR-TOOLTIP2 sy-vline
WA_/SCF/BARS_STR_STR-TOOLTIP3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.