ABAP Select data from SAP table /SAPSLL/CUHD_LOAD_CP_CTRL_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPSLL/CUHD_LOAD_CP_CTRL_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPSLL/CUHD_LOAD_CP_CTRL_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPSLL/CUHD_LOAD_CP_CTRL_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S TYPE STANDARD TABLE OF /SAPSLL/CUHD_LOAD_CP_CTRL_S,
      WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S TYPE /SAPSLL/CUHD_LOAD_CP_CTRL_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPSLL/CUHD_LOAD_CP_CTRL_S> TYPE /SAPSLL/CUHD_LOAD_CP_CTRL_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPSLL/CUHD_LOAD_CP_CTRL_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPSLL/CUHD_LOAD_CP_CTRL_S
  INTO TABLE IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPSLL/CUHD_LOAD_CP_CTRL_S
*  INTO TABLE @DATA(IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S INDEX 1 INTO DATA(WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S ASSIGNING </SAPSLL/CUHD_LOAD_CP_CTRL_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPSLL/CUHD_LOAD_CP_CTRL_S>-ACTIVITY = 1.
</SAPSLL/CUHD_LOAD_CP_CTRL_S>-LNDAB = 1.
</SAPSLL/CUHD_LOAD_CP_CTRL_S>-INDEI = 1.
</SAPSLL/CUHD_LOAD_CP_CTRL_S>-PROCS_T = 1.
</SAPSLL/CUHD_LOAD_CP_CTRL_S>-KZUIM = 1.
ENDLOOP.

LOOP AT IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S INTO WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIW, sy-vline,
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIP, sy-vline,
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIB, sy-vline,
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIA, sy-vline,
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIF, sy-vline,
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-KZUIZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPSLL/CUHD_LOAD_CP_CTRL_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPSLL/CUHD_LOAD_CP_CTRL_S INTO WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-CORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S-CORDER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR,
ACTIVITY TYPE STRING,
LNDAB TYPE STRING,
INDEI TYPE STRING,
PROCS_T TYPE STRING,
KZUIM TYPE STRING,
KZUIW TYPE STRING,
KZUIP TYPE STRING,
KZUIB TYPE STRING,
KZUIA TYPE STRING,
KZUIF TYPE STRING,
KZUIZ TYPE STRING,
KZUIK TYPE STRING,
KZUIS TYPE STRING,
KZUIC TYPE STRING,
KZUIE TYPE STRING,
KZUIT TYPE STRING,
KZUIV TYPE STRING,
INDEI TYPE STRING,
CDTYP TYPE STRING,
FCODE TYPE STRING,
CREATE_TREE TYPE STRING,
NODE_KEY TYPE STRING,
SRVLL TYPE STRING,
REGTY TYPE STRING,
PROSS TYPE STRING,
TOP_KEY TYPE STRING,
CUHD_SK TYPE STRING,
CORDER TYPE STRING,
COYEAR TYPE STRING,
REPID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-ACTIVITY sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-LNDAB sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-INDEI sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-PROCS_T sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIM sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIW sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIP sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIB sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIA sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIF sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIZ sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIK sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIS sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIC sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIE sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIT sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-KZUIV sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-INDEI sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-CDTYP sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-FCODE sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-CREATE_TREE sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-NODE_KEY sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-SRVLL sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-REGTY sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-PROSS sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-TOP_KEY sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-CUHD_SK sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-CORDER sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-COYEAR sy-vline
WA_/SAPSLL/CUHD_LOAD_CP_CTRL_S_STR-REPID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.