ABAP Select data from SAP table /SAPSLL/CUHD_LOAD_0190_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPSLL/CUHD_LOAD_0190_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPSLL/CUHD_LOAD_0190_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPSLL/CUHD_LOAD_0190_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPSLL/CUHD_LOAD_0190_S TYPE STANDARD TABLE OF /SAPSLL/CUHD_LOAD_0190_S,
      WA_/SAPSLL/CUHD_LOAD_0190_S TYPE /SAPSLL/CUHD_LOAD_0190_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPSLL/CUHD_LOAD_0190_S> TYPE /SAPSLL/CUHD_LOAD_0190_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPSLL/CUHD_LOAD_0190_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPSLL/CUHD_LOAD_0190_S
  INTO TABLE IT_/SAPSLL/CUHD_LOAD_0190_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPSLL/CUHD_LOAD_0190_S
*  INTO TABLE @DATA(IT_/SAPSLL/CUHD_LOAD_0190_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPSLL/CUHD_LOAD_0190_S INDEX 1 INTO DATA(WA_/SAPSLL/CUHD_LOAD_0190_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPSLL/CUHD_LOAD_0190_S ASSIGNING </SAPSLL/CUHD_LOAD_0190_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPSLL/CUHD_LOAD_0190_S>-INVOICE = 1.
</SAPSLL/CUHD_LOAD_0190_S>-INVNR = 1.
</SAPSLL/CUHD_LOAD_0190_S>-INVDT = 1.
</SAPSLL/CUHD_LOAD_0190_S>-FLIOC = 1.
</SAPSLL/CUHD_LOAD_0190_S>-FLRLC = 1.
ENDLOOP.

LOOP AT IT_/SAPSLL/CUHD_LOAD_0190_S INTO WA_/SAPSLL/CUHD_LOAD_0190_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPSLL/CUHD_LOAD_0190_S-RLCTX, sy-vline,
WA_/SAPSLL/CUHD_LOAD_0190_S-CUSCS_PYTYP, sy-vline,
WA_/SAPSLL/CUHD_LOAD_0190_S-PYTYP, sy-vline,
WA_/SAPSLL/CUHD_LOAD_0190_S-FLITX, sy-vline,
WA_/SAPSLL/CUHD_LOAD_0190_S-FLCVD, sy-vline,
WA_/SAPSLL/CUHD_LOAD_0190_S-CULID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPSLL/CUHD_LOAD_0190_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPSLL/CUHD_LOAD_0190_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPSLL/CUHD_LOAD_0190_S INTO WA_/SAPSLL/CUHD_LOAD_0190_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INVNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPSLL/CUHD_LOAD_0190_S-INVNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSLL/CUHD_LOAD_0190_S-INVNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUSPA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPSLL/CUHD_LOAD_0190_S-SUSPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPSLL/CUHD_LOAD_0190_S-SUSPA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPSLL/CUHD_LOAD_0190_S_STR,
INVOICE TYPE STRING,
INVNR TYPE STRING,
INVDT TYPE STRING,
FLIOC TYPE STRING,
FLRLC TYPE STRING,
RLCTX TYPE STRING,
CUSCS_PYTYP TYPE STRING,
PYTYP TYPE STRING,
FLITX TYPE STRING,
FLCVD TYPE STRING,
CULID TYPE STRING,
LIDTX TYPE STRING,
CULIM TYPE STRING,
LIMTX TYPE STRING,
CUFWS TYPE STRING,
FWSTX TYPE STRING,
CUBED TYPE STRING,
SUSPENSION TYPE STRING,
CUSCS_SUSTY TYPE STRING,
SUSTY TYPE STRING,
SUSST TYPE STRING,
SUSAR TYPE STRING,
SUSPA TYPE STRING,
DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPSLL/CUHD_LOAD_0190_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-INVOICE sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-INVNR sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-INVDT sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-FLIOC sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-FLRLC sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-RLCTX sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CUSCS_PYTYP sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-PYTYP sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-FLITX sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-FLCVD sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CULID sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-LIDTX sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CULIM sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-LIMTX sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CUFWS sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-FWSTX sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CUBED sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-SUSPENSION sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-CUSCS_SUSTY sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-SUSTY sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-SUSST sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-SUSAR sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-SUSPA sy-vline
WA_/SAPSLL/CUHD_LOAD_0190_S_STR-DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.