ABAP Select data from SAP table /SAPCEM/BAPI_SDCEM_UPD_IX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPCEM/BAPI_SDCEM_UPD_IX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPCEM/BAPI_SDCEM_UPD_IX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPCEM/BAPI_SDCEM_UPD_IX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPCEM/BAPI_SDCEM_UPD_IX TYPE STANDARD TABLE OF /SAPCEM/BAPI_SDCEM_UPD_IX,
      WA_/SAPCEM/BAPI_SDCEM_UPD_IX TYPE /SAPCEM/BAPI_SDCEM_UPD_IX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPCEM/BAPI_SDCEM_UPD_IX> TYPE /SAPCEM/BAPI_SDCEM_UPD_IX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPCEM/BAPI_SDCEM_UPD_IX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPCEM/BAPI_SDCEM_UPD_IX
  INTO TABLE IT_/SAPCEM/BAPI_SDCEM_UPD_IX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPCEM/BAPI_SDCEM_UPD_IX
*  INTO TABLE @DATA(IT_/SAPCEM/BAPI_SDCEM_UPD_IX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPCEM/BAPI_SDCEM_UPD_IX INDEX 1 INTO DATA(WA_/SAPCEM/BAPI_SDCEM_UPD_IX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPCEM/BAPI_SDCEM_UPD_IX ASSIGNING </SAPCEM/BAPI_SDCEM_UPD_IX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPCEM/BAPI_SDCEM_UPD_IX>-ITM_NUMBER = 1.
</SAPCEM/BAPI_SDCEM_UPD_IX>-UPDATEFLAG = 1.
</SAPCEM/BAPI_SDCEM_UPD_IX>-EQUIPMENT = 1.
</SAPCEM/BAPI_SDCEM_UPD_IX>-MATERIAL = 1.
</SAPCEM/BAPI_SDCEM_UPD_IX>-ACTY_TYPE = 1.
ENDLOOP.

LOOP AT IT_/SAPCEM/BAPI_SDCEM_UPD_IX INTO WA_/SAPCEM/BAPI_SDCEM_UPD_IX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPCEM/BAPI_SDCEM_UPD_IX-QUANTITY, sy-vline,
WA_/SAPCEM/BAPI_SDCEM_UPD_IX-QUANTITY_UNIT, sy-vline,
WA_/SAPCEM/BAPI_SDCEM_UPD_IX-QUANTITY_UNIT_ISO, sy-vline,
WA_/SAPCEM/BAPI_SDCEM_UPD_IX-BILLING_NUMBER_EXTERN, sy-vline,
WA_/SAPCEM/BAPI_SDCEM_UPD_IX-END_OF_USAGE, sy-vline,
WA_/SAPCEM/BAPI_SDCEM_UPD_IX-BATCH_SENDER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPCEM/BAPI_SDCEM_UPD_IX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPCEM/BAPI_SDCEM_UPD_IX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPCEM/BAPI_SDCEM_UPD_IX INTO WA_/SAPCEM/BAPI_SDCEM_UPD_IX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPCEM/BAPI_SDCEM_UPD_IX_STR,
ITM_NUMBER TYPE STRING,
UPDATEFLAG TYPE STRING,
EQUIPMENT TYPE STRING,
MATERIAL TYPE STRING,
ACTY_TYPE TYPE STRING,
QUANTITY TYPE STRING,
QUANTITY_UNIT TYPE STRING,
QUANTITY_UNIT_ISO TYPE STRING,
BILLING_NUMBER_EXTERN TYPE STRING,
END_OF_USAGE TYPE STRING,
BATCH_SENDER TYPE STRING,
BATCH_RECIPIENT TYPE STRING,
COMMENT1 TYPE STRING,
COMMENT2 TYPE STRING,
USERFIELD0 TYPE STRING,
USERFIELD1 TYPE STRING,
USERFIELD2 TYPE STRING,
USERFIELD3 TYPE STRING,
USERFIELD_QUAN1 TYPE STRING,
USERFIELD_UNIT1 TYPE STRING,
USERFIELD_UNIT1_ISO TYPE STRING,
USERFIELD_QUAN2 TYPE STRING,
USERFIELD_UNIT2 TYPE STRING,
USERFIELD_UNIT2_ISO TYPE STRING,
USERFIELD_CURR1 TYPE STRING,
USERFIELD_CURR1_UNIT TYPE STRING,
USERFIELD_CURR1_UNIT_ISO TYPE STRING,
USERFIELD_CURR2 TYPE STRING,
USERFIELD_CURR2_UNIT TYPE STRING,
USERFIELD_CURR2_UNIT_ISO TYPE STRING,
USERFIELD_DAT1 TYPE STRING,
USERFIELD_DAT1_ISO_ZONE TYPE STRING,
USERFIELD_DAT1_ISO_STAMP TYPE STRING,
USERFIELD_DAT2 TYPE STRING,
USERFIELD_DAT2_ISO_ZONE TYPE STRING,
USERFIELD_DAT2_ISO_STAMP TYPE STRING,
USERFIELD_FLAG1 TYPE STRING,
USERFIELD_FLAG2 TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-ITM_NUMBER sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-UPDATEFLAG sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-EQUIPMENT sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-MATERIAL sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-ACTY_TYPE sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-QUANTITY sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-QUANTITY_UNIT sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-QUANTITY_UNIT_ISO sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-BILLING_NUMBER_EXTERN sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-END_OF_USAGE sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-BATCH_SENDER sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-BATCH_RECIPIENT sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-COMMENT1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-COMMENT2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD0 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD3 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_QUAN1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_UNIT1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_UNIT1_ISO sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_QUAN2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_UNIT2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_UNIT2_ISO sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR1_UNIT sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR1_UNIT_ISO sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR2_UNIT sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_CURR2_UNIT_ISO sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT1_ISO_ZONE sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT1_ISO_STAMP sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT2_ISO_ZONE sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_DAT2_ISO_STAMP sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_FLAG1 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-USERFIELD_FLAG2 sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-MATERIAL_EXTERNAL sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-MATERIAL_GUID sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-MATERIAL_VERSION sy-vline
WA_/SAPCEM/BAPI_SDCEM_UPD_IX_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.