ABAP Select data from SAP table /SAPCE/FKUA_S_TCKT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPCE/FKUA_S_TCKT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPCE/FKUA_S_TCKT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPCE/FKUA_S_TCKT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPCE/FKUA_S_TCKT TYPE STANDARD TABLE OF /SAPCE/FKUA_S_TCKT,
      WA_/SAPCE/FKUA_S_TCKT TYPE /SAPCE/FKUA_S_TCKT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPCE/FKUA_S_TCKT> TYPE /SAPCE/FKUA_S_TCKT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPCE/FKUA_S_TCKT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPCE/FKUA_S_TCKT
  INTO TABLE IT_/SAPCE/FKUA_S_TCKT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPCE/FKUA_S_TCKT
*  INTO TABLE @DATA(IT_/SAPCE/FKUA_S_TCKT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPCE/FKUA_S_TCKT INDEX 1 INTO DATA(WA_/SAPCE/FKUA_S_TCKT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPCE/FKUA_S_TCKT ASSIGNING </SAPCE/FKUA_S_TCKT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPCE/FKUA_S_TCKT>-HDATE = 1.
</SAPCE/FKUA_S_TCKT>-HTIME = 1.
</SAPCE/FKUA_S_TCKT>-HNUMREG = 1.
</SAPCE/FKUA_S_TCKT>-HRESULT = 1.
</SAPCE/FKUA_S_TCKT>-HFILL = 1.
ENDLOOP.

LOOP AT IT_/SAPCE/FKUA_S_TCKT INTO WA_/SAPCE/FKUA_S_TCKT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPCE/FKUA_S_TCKT-HNUM, sy-vline,
WA_/SAPCE/FKUA_S_TCKT-HNUM1, sy-vline,
WA_/SAPCE/FKUA_S_TCKT-HNUM2, sy-vline,
WA_/SAPCE/FKUA_S_TCKT-HPODFILL, sy-vline,
WA_/SAPCE/FKUA_S_TCKT-HPODNUM, sy-vline,
WA_/SAPCE/FKUA_S_TCKT-HPODNUM1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPCE/FKUA_S_TCKT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPCE/FKUA_S_TCKT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPCE/FKUA_S_TCKT INTO WA_/SAPCE/FKUA_S_TCKT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPCE/FKUA_S_TCKT-HNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPCE/FKUA_S_TCKT-HNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HPODNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SAPCE/FKUA_S_TCKT-HPODNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPCE/FKUA_S_TCKT-HPODNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field TXJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/SAPCE/FKUA_S_TCKT-TXJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPCE/FKUA_S_TCKT-TXJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPCE/FKUA_S_TCKT_STR,
HDATE TYPE STRING,
HTIME TYPE STRING,
HNUMREG TYPE STRING,
HRESULT TYPE STRING,
HFILL TYPE STRING,
HNUM TYPE STRING,
HNUM1 TYPE STRING,
HNUM2 TYPE STRING,
HPODFILL TYPE STRING,
HPODNUM TYPE STRING,
HPODNUM1 TYPE STRING,
HPODNUM2 TYPE STRING,
TXJAHR TYPE STRING,
TXMONTH TYPE STRING,
REGTV TYPE STRING,
DOC_ACCEPTED TYPE STRING,
DOC_REJECTED TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPCE/FKUA_S_TCKT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HDATE sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HTIME sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HNUMREG sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HRESULT sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HFILL sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HNUM sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HNUM1 sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HNUM2 sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HPODFILL sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HPODNUM sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HPODNUM1 sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-HPODNUM2 sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-TXJAHR sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-TXMONTH sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-REGTV sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-DOC_ACCEPTED sy-vline
WA_/SAPCE/FKUA_S_TCKT_STR-DOC_REJECTED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.