ABAP Select data from SAP table /SAPAPO/LOC_LOCVER_MASS_IO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPAPO/LOC_LOCVER_MASS_IO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPAPO/LOC_LOCVER_MASS_IO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPAPO/LOC_LOCVER_MASS_IO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPAPO/LOC_LOCVER_MASS_IO TYPE STANDARD TABLE OF /SAPAPO/LOC_LOCVER_MASS_IO,
      WA_/SAPAPO/LOC_LOCVER_MASS_IO TYPE /SAPAPO/LOC_LOCVER_MASS_IO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPAPO/LOC_LOCVER_MASS_IO> TYPE /SAPAPO/LOC_LOCVER_MASS_IO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPAPO/LOC_LOCVER_MASS_IO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPAPO/LOC_LOCVER_MASS_IO
  INTO TABLE IT_/SAPAPO/LOC_LOCVER_MASS_IO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPAPO/LOC_LOCVER_MASS_IO
*  INTO TABLE @DATA(IT_/SAPAPO/LOC_LOCVER_MASS_IO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPAPO/LOC_LOCVER_MASS_IO INDEX 1 INTO DATA(WA_/SAPAPO/LOC_LOCVER_MASS_IO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPAPO/LOC_LOCVER_MASS_IO ASSIGNING </SAPAPO/LOC_LOCVER_MASS_IO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPAPO/LOC_LOCVER_MASS_IO>-LOCNO = 1.
</SAPAPO/LOC_LOCVER_MASS_IO>-VRSIOEX = 1.
</SAPAPO/LOC_LOCVER_MASS_IO>-LOCID = 1.
</SAPAPO/LOC_LOCVER_MASS_IO>-SIMID = 1.
</SAPAPO/LOC_LOCVER_MASS_IO>-CONHINB = 1.
ENDLOOP.

LOOP AT IT_/SAPAPO/LOC_LOCVER_MASS_IO INTO WA_/SAPAPO/LOC_LOCVER_MASS_IO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB, sy-vline,
WA_/SAPAPO/LOC_LOCVER_MASS_IO-CONHINB_TP, sy-vline,
WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB_TP, sy-vline,
WA_/SAPAPO/LOC_LOCVER_MASS_IO-CONHOUT, sy-vline,
WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITOUT, sy-vline,
WA_/SAPAPO/LOC_LOCVER_MASS_IO-CONHOUT_TP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPAPO/LOC_LOCVER_MASS_IO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPAPO/LOC_LOCVER_MASS_IO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPAPO/LOC_LOCVER_MASS_IO INTO WA_/SAPAPO/LOC_LOCVER_MASS_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNITINB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITINB_TP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB_TP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITINB_TP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITOUT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITOUT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITOUT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITOUT_TP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITOUT_TP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-UNITOUT_TP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRN, internal->external for field TSDURAT CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-TSDURAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-TSDURAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRN, internal->external for field TSDURAT_MIN CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_/SAPAPO/LOC_LOCVER_MASS_IO-TSDURAT_MIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/LOC_LOCVER_MASS_IO-TSDURAT_MIN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPAPO/LOC_LOCVER_MASS_IO_STR,
LOCNO TYPE STRING,
VRSIOEX TYPE STRING,
LOCID TYPE STRING,
SIMID TYPE STRING,
CONHINB TYPE STRING,
UNITINB TYPE STRING,
CONHINB_TP TYPE STRING,
UNITINB_TP TYPE STRING,
CONHOUT TYPE STRING,
UNITOUT TYPE STRING,
CONHOUT_TP TYPE STRING,
UNITOUT_TP TYPE STRING,
TSDURAT TYPE STRING,
TSDURAT_MIN TYPE STRING,
STKPROFID TYPE STRING,
DSTKPROFID TYPE STRING,
WSSPROFID TYPE STRING,
MINSRPLVALLMT TYPE STRING,
SRPLAPPRVALLMT TYPE STRING,
NDLOCPRFID TYPE STRING,
NDLOCPRFEX TYPE STRING,
NDLOCPRFTXT TYPE STRING,
LOCNEU TYPE STRING,
MDPW TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-LOCNO sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-VRSIOEX sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-LOCID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-SIMID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-CONHINB sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-UNITINB sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-CONHINB_TP sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-UNITINB_TP sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-CONHOUT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-UNITOUT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-CONHOUT_TP sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-UNITOUT_TP sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-TSDURAT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-TSDURAT_MIN sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-STKPROFID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-DSTKPROFID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-WSSPROFID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-MINSRPLVALLMT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-SRPLAPPRVALLMT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-NDLOCPRFID sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-NDLOCPRFEX sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-NDLOCPRFTXT sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-LOCNEU sy-vline
WA_/SAPAPO/LOC_LOCVER_MASS_IO_STR-MDPW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.