ABAP Select data from SAP table /RPM/TS_BUCKET_DASH_ATT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /RPM/TS_BUCKET_DASH_ATT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /RPM/TS_BUCKET_DASH_ATT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /RPM/TS_BUCKET_DASH_ATT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/RPM/TS_BUCKET_DASH_ATT TYPE STANDARD TABLE OF /RPM/TS_BUCKET_DASH_ATT, WA_/RPM/TS_BUCKET_DASH_ATT TYPE /RPM/TS_BUCKET_DASH_ATT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </RPM/TS_BUCKET_DASH_ATT> TYPE /RPM/TS_BUCKET_DASH_ATT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/RPM/TS_BUCKET_DASH_ATT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /RPM/TS_BUCKET_DASH_ATT INTO TABLE IT_/RPM/TS_BUCKET_DASH_ATT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /RPM/TS_BUCKET_DASH_ATT * INTO TABLE @DATA(IT_/RPM/TS_BUCKET_DASH_ATT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/RPM/TS_BUCKET_DASH_ATT INDEX 1 INTO DATA(WA_/RPM/TS_BUCKET_DASH_ATT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/RPM/TS_BUCKET_DASH_ATT ASSIGNING </RPM/TS_BUCKET_DASH_ATT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</RPM/TS_BUCKET_DASH_ATT>-DESCRIPTION = 1.
</RPM/TS_BUCKET_DASH_ATT>-EXTERNAL_ID = 1.
</RPM/TS_BUCKET_DASH_ATT>-CHANGED_BY = 1.
</RPM/TS_BUCKET_DASH_ATT>-CHANGED_ON = 1.
</RPM/TS_BUCKET_DASH_ATT>-PERIOD_TYPE = 1.
ENDLOOP. LOOP AT IT_/RPM/TS_BUCKET_DASH_ATT INTO WA_/RPM/TS_BUCKET_DASH_ATT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/RPM/TS_BUCKET_DASH_ATT-UNIT, sy-vline,
WA_/RPM/TS_BUCKET_DASH_ATT-CAP_PERIOD_TYPE, sy-vline,
WA_/RPM/TS_BUCKET_DASH_ATT-LOCATION, sy-vline,
WA_/RPM/TS_BUCKET_DASH_ATT-RELEASE_STATUS, sy-vline,
WA_/RPM/TS_BUCKET_DASH_ATT-BEGDA_DEM, sy-vline,
WA_/RPM/TS_BUCKET_DASH_ATT-ENDDA_DEM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/RPM/TS_BUCKET_DASH_ATT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/RPM/TS_BUCKET_DASH_ATT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/RPM/TS_BUCKET_DASH_ATT INTO WA_/RPM/TS_BUCKET_DASH_ATT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TSTPS, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/RPM/TS_BUCKET_DASH_ATT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/RPM/TS_BUCKET_DASH_ATT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/RPM/TS_BUCKET_DASH_ATT-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/RPM/TS_BUCKET_DASH_ATT-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/RPM/TS_BUCKET_DASH_ATT_STR,
DESCRIPTION TYPE STRING,
EXTERNAL_ID TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
PERIOD_TYPE TYPE STRING,
UNIT TYPE STRING,
CAP_PERIOD_TYPE TYPE STRING,
LOCATION TYPE STRING,
RELEASE_STATUS TYPE STRING,
BEGDA_DEM TYPE STRING,
ENDDA_DEM TYPE STRING,
BEGDA_FIN TYPE STRING,
ENDDA_FIN TYPE STRING,
CNT_REVIEWS TYPE STRING,
CNT_ITEMS TYPE STRING,
HAS_CHILDREN TYPE STRING,
D_CHANGED_ON TYPE STRING,
D_CREATED_ON TYPE STRING,
PARENT_DESCRIPTION TYPE STRING,
CNT_INITIATIVES TYPE STRING,
CNT_ITEM_TEMPLATES TYPE STRING,
CNT_IPO_TEMPLATES TYPE STRING,
CURRENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/RPM/TS_BUCKET_DASH_ATT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-DESCRIPTION sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-EXTERNAL_ID sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CHANGED_BY sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CHANGED_ON sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-PERIOD_TYPE sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-UNIT sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CAP_PERIOD_TYPE sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-LOCATION sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-RELEASE_STATUS sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-BEGDA_DEM sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-ENDDA_DEM sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-BEGDA_FIN sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-ENDDA_FIN sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CNT_REVIEWS sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CNT_ITEMS sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-HAS_CHILDREN sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-D_CHANGED_ON sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-D_CREATED_ON sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-PARENT_DESCRIPTION sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CNT_INITIATIVES sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CNT_ITEM_TEMPLATES sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CNT_IPO_TEMPLATES sy-vline
WA_/RPM/TS_BUCKET_DASH_ATT_STR-CURRENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.