ABAP Select data from SAP table /PRA/S_OIURV_TCD_H_DB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PRA/S_OIURV_TCD_H_DB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PRA/S_OIURV_TCD_H_DB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PRA/S_OIURV_TCD_H_DB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PRA/S_OIURV_TCD_H_DB TYPE STANDARD TABLE OF /PRA/S_OIURV_TCD_H_DB,
      WA_/PRA/S_OIURV_TCD_H_DB TYPE /PRA/S_OIURV_TCD_H_DB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PRA/S_OIURV_TCD_H_DB> TYPE /PRA/S_OIURV_TCD_H_DB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PRA/S_OIURV_TCD_H_DB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PRA/S_OIURV_TCD_H_DB
  INTO TABLE IT_/PRA/S_OIURV_TCD_H_DB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PRA/S_OIURV_TCD_H_DB
*  INTO TABLE @DATA(IT_/PRA/S_OIURV_TCD_H_DB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PRA/S_OIURV_TCD_H_DB INDEX 1 INTO DATA(WA_/PRA/S_OIURV_TCD_H_DB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PRA/S_OIURV_TCD_H_DB ASSIGNING </PRA/S_OIURV_TCD_H_DB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PRA/S_OIURV_TCD_H_DB>-MANDT = 1.
</PRA/S_OIURV_TCD_H_DB>-LAND1 = 1.
</PRA/S_OIURV_TCD_H_DB>-PRI_GEO_LOC = 1.
</PRA/S_OIURV_TCD_H_DB>-MAJPD_CD = 1.
</PRA/S_OIURV_TCD_H_DB>-MATNR = 1.
ENDLOOP.

LOOP AT IT_/PRA/S_OIURV_TCD_H_DB INTO WA_/PRA/S_OIURV_TCD_H_DB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PRA/S_OIURV_TCD_H_DB-VL_TYPE_CD, sy-vline,
WA_/PRA/S_OIURV_TCD_H_DB-SEVT_TAX_TY, sy-vline,
WA_/PRA/S_OIURV_TCD_H_DB-EFF_FROM_DT, sy-vline,
WA_/PRA/S_OIURV_TCD_H_DB-TCD_NO, sy-vline,
WA_/PRA/S_OIURV_TCD_H_DB-EFF_TO_DT, sy-vline,
WA_/PRA/S_OIURV_TCD_H_DB-TAX_CLASS_FL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PRA/S_OIURV_TCD_H_DB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PRA/S_OIURV_TCD_H_DB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PRA/S_OIURV_TCD_H_DB INTO WA_/PRA/S_OIURV_TCD_H_DB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PRA/S_OIURV_TCD_H_DB-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_OIURV_TCD_H_DB-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEAS_UNIT_NM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_OIURV_TCD_H_DB-MEAS_UNIT_NM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_OIURV_TCD_H_DB-MEAS_UNIT_NM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PRA/S_OIURV_TCD_H_DB_STR,
MANDT TYPE STRING,
LAND1 TYPE STRING,
PRI_GEO_LOC TYPE STRING,
MAJPD_CD TYPE STRING,
MATNR TYPE STRING,
VL_TYPE_CD TYPE STRING,
SEVT_TAX_TY TYPE STRING,
EFF_FROM_DT TYPE STRING,
TCD_NO TYPE STRING,
EFF_TO_DT TYPE STRING,
TAX_CLASS_FL TYPE STRING,
MEAS_UNIT_NM TYPE STRING,
CURR TYPE STRING,
FX_MCD_RAT TYPE STRING,
FX_MCD TYPE STRING,
RMB_TAX_CD TYPE STRING,
EXMP_TAX_CLS TYPE STRING,
GR_UP_RMB_FL TYPE STRING,
ONE_PC_GAS_RMB_F TYPE STRING,
INCL_TAX_FREE_05 TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PRA/S_OIURV_TCD_H_DB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-MANDT sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-LAND1 sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-PRI_GEO_LOC sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-MAJPD_CD sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-MATNR sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-VL_TYPE_CD sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-SEVT_TAX_TY sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-EFF_FROM_DT sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-TCD_NO sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-EFF_TO_DT sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-TAX_CLASS_FL sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-MEAS_UNIT_NM sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-CURR sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-FX_MCD_RAT sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-FX_MCD sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-RMB_TAX_CD sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-EXMP_TAX_CLS sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-GR_UP_RMB_FL sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-ONE_PC_GAS_RMB_F sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-INCL_TAX_FREE_05 sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-OIU_CRUSER sy-vline
WA_/PRA/S_OIURV_TCD_H_DB_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.