ABAP Select data from SAP table /PRA/S_CA_MANUAL_UPLD_TEMPLATE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PRA/S_CA_MANUAL_UPLD_TEMPLATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PRA/S_CA_MANUAL_UPLD_TEMPLATE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PRA/S_CA_MANUAL_UPLD_TEMPLATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE TYPE STANDARD TABLE OF /PRA/S_CA_MANUAL_UPLD_TEMPLATE,
      WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE TYPE /PRA/S_CA_MANUAL_UPLD_TEMPLATE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PRA/S_CA_MANUAL_UPLD_TEMPLATE> TYPE /PRA/S_CA_MANUAL_UPLD_TEMPLATE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PRA/S_CA_MANUAL_UPLD_TEMPLATE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PRA/S_CA_MANUAL_UPLD_TEMPLATE
  INTO TABLE IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PRA/S_CA_MANUAL_UPLD_TEMPLATE
*  INTO TABLE @DATA(IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE INDEX 1 INTO DATA(WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE ASSIGNING </PRA/S_CA_MANUAL_UPLD_TEMPLATE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PRA/S_CA_MANUAL_UPLD_TEMPLATE>-DEL_IND = 1.
</PRA/S_CA_MANUAL_UPLD_TEMPLATE>-DN_NO = 1.
</PRA/S_CA_MANUAL_UPLD_TEMPLATE>-SA_DT = 1.
</PRA/S_CA_MANUAL_UPLD_TEMPLATE>-WL_NO = 1.
</PRA/S_CA_MANUAL_UPLD_TEMPLATE>-WC_NO = 1.
ENDLOOP.

LOOP AT IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE INTO WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MP_NO, sy-vline,
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-ORIG_MP_NO, sy-vline,
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-TRNSP_NO, sy-vline,
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MATNR, sy-vline,
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-FREQ_CD, sy-vline,
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-CT_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PRA/S_CA_MANUAL_UPLD_TEMPLATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PRA/S_CA_MANUAL_UPLD_TEMPLATE INTO WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-DN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-WC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIG_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-ORIG_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-ORIG_MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CT_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-CT_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-CT_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STD_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_VOL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STD_HEAT_VAL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_HEAT_VAL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_HEAT_VAL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STD_ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE-STD_ENERGY_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR,
DEL_IND TYPE STRING,
DN_NO TYPE STRING,
SA_DT TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
MP_NO TYPE STRING,
ORIG_MP_NO TYPE STRING,
TRNSP_NO TYPE STRING,
MATNR TYPE STRING,
FREQ_CD TYPE STRING,
CT_NO TYPE STRING,
STD_VOL_U TYPE STRING,
STD_VOL TYPE STRING,
STD_HEAT_VAL_U TYPE STRING,
STD_HEAT_VAL TYPE STRING,
STD_ENERGY_U TYPE STRING,
STD_ENERGY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-DEL_IND sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-DN_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-SA_DT sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-WL_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-WC_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-MP_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-ORIG_MP_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-TRNSP_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-MATNR sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-FREQ_CD sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-CT_NO sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_VOL_U sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_VOL sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_HEAT_VAL_U sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_HEAT_VAL sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_ENERGY_U sy-vline
WA_/PRA/S_CA_MANUAL_UPLD_TEMPLATE_STR-STD_ENERGY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.