ABAP Select data from SAP table /PRA/S_CA_GA_CONVERSION_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PRA/S_CA_GA_CONVERSION_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PRA/S_CA_GA_CONVERSION_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PRA/S_CA_GA_CONVERSION_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PRA/S_CA_GA_CONVERSION_ALV TYPE STANDARD TABLE OF /PRA/S_CA_GA_CONVERSION_ALV,
      WA_/PRA/S_CA_GA_CONVERSION_ALV TYPE /PRA/S_CA_GA_CONVERSION_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PRA/S_CA_GA_CONVERSION_ALV> TYPE /PRA/S_CA_GA_CONVERSION_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PRA/S_CA_GA_CONVERSION_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PRA/S_CA_GA_CONVERSION_ALV
  INTO TABLE IT_/PRA/S_CA_GA_CONVERSION_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PRA/S_CA_GA_CONVERSION_ALV
*  INTO TABLE @DATA(IT_/PRA/S_CA_GA_CONVERSION_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PRA/S_CA_GA_CONVERSION_ALV INDEX 1 INTO DATA(WA_/PRA/S_CA_GA_CONVERSION_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PRA/S_CA_GA_CONVERSION_ALV ASSIGNING </PRA/S_CA_GA_CONVERSION_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PRA/S_CA_GA_CONVERSION_ALV>-DN_NO = 1.
</PRA/S_CA_GA_CONVERSION_ALV>-MEAS_GRP_ID = 1.
</PRA/S_CA_GA_CONVERSION_ALV>-EFF_FROM_DT = 1.
</PRA/S_CA_GA_CONVERSION_ALV>-EFF_TO_DT = 1.
</PRA/S_CA_GA_CONVERSION_ALV>-MATNR = 1.
ENDLOOP.

LOOP AT IT_/PRA/S_CA_GA_CONVERSION_ALV INTO WA_/PRA/S_CA_GA_CONVERSION_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PRA/S_CA_GA_CONVERSION_ALV-MAKTX, sy-vline,
WA_/PRA/S_CA_GA_CONVERSION_ALV-UOM, sy-vline,
WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME, sy-vline,
WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME_U, sy-vline,
WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY, sy-vline,
WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY_U, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PRA/S_CA_GA_CONVERSION_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PRA/S_CA_GA_CONVERSION_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PRA/S_CA_GA_CONVERSION_ALV INTO WA_/PRA/S_CA_GA_CONVERSION_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-DN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SFACT, internal->external for field SHRINK_VOLUME CALL FUNCTION 'CONVERSION_EXIT_SFACT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SHRINK_VOLUME_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_VOLUME_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SFACT, internal->external for field SHRINK_ENERGY CALL FUNCTION 'CONVERSION_EXIT_SFACT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SHRINK_ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-SHRINK_ENERGY_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit OIUNM, internal->external for field DN_DE CALL FUNCTION 'CONVERSION_EXIT_OIUNM_OUTPUT' EXPORTING input = WA_/PRA/S_CA_GA_CONVERSION_ALV-DN_DE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_CA_GA_CONVERSION_ALV-DN_DE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PRA/S_CA_GA_CONVERSION_ALV_STR,
DN_NO TYPE STRING,
MEAS_GRP_ID TYPE STRING,
EFF_FROM_DT TYPE STRING,
EFF_TO_DT TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
UOM TYPE STRING,
SHRINK_VOLUME TYPE STRING,
SHRINK_VOLUME_U TYPE STRING,
SHRINK_ENERGY TYPE STRING,
SHRINK_ENERGY_U TYPE STRING,
DN_DE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PRA/S_CA_GA_CONVERSION_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-DN_NO sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-MEAS_GRP_ID sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-EFF_FROM_DT sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-EFF_TO_DT sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-MATNR sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-MAKTX sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-UOM sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-SHRINK_VOLUME sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-SHRINK_VOLUME_U sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-SHRINK_ENERGY sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-SHRINK_ENERGY_U sy-vline
WA_/PRA/S_CA_GA_CONVERSION_ALV_STR-DN_DE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.