ABAP Select data from SAP table /PM0/PCRP_I_PCR_MNG_CVP_RQ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/PCRP_I_PCR_MNG_CVP_RQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/PCRP_I_PCR_MNG_CVP_RQ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/PCRP_I_PCR_MNG_CVP_RQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ TYPE STANDARD TABLE OF /PM0/PCRP_I_PCR_MNG_CVP_RQ,
      WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ TYPE /PM0/PCRP_I_PCR_MNG_CVP_RQ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/PCRP_I_PCR_MNG_CVP_RQ> TYPE /PM0/PCRP_I_PCR_MNG_CVP_RQ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/PCRP_I_PCR_MNG_CVP_RQ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/PCRP_I_PCR_MNG_CVP_RQ
  INTO TABLE IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/PCRP_I_PCR_MNG_CVP_RQ
*  INTO TABLE @DATA(IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ INDEX 1 INTO DATA(WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ ASSIGNING </PM0/PCRP_I_PCR_MNG_CVP_RQ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/PCRP_I_PCR_MNG_CVP_RQ>-MESSAGE_HEADER = 1.
</PM0/PCRP_I_PCR_MNG_CVP_RQ>-ID = 1.
</PM0/PCRP_I_PCR_MNG_CVP_RQ>-SCHEME_ID = 1.
</PM0/PCRP_I_PCR_MNG_CVP_RQ>-SCHEME_AGENCY_ID = 1.
</PM0/PCRP_I_PCR_MNG_CVP_RQ>-SCHEME_AGENCY_SCHEME_AGENCY_ID = 1.
ENDLOOP.

LOOP AT IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ INTO WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-CONTENT, sy-vline,
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-UUID, sy-vline,
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-SCHEME_ID, sy-vline,
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-SCHEME_AGENCY_ID, sy-vline,
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-CONTENT, sy-vline,
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-REFERENCE_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/PCRP_I_PCR_MNG_CVP_RQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/PCRP_I_PCR_MNG_CVP_RQ INTO WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field IV_APPLNR_CD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-IV_APPLNR_CD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ-IV_APPLNR_CD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR,
MESSAGE_HEADER TYPE STRING,
ID TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
UUID TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
REFERENCE_ID TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
REFERENCE_UUID TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
CREATION_DATE_TIME TYPE STRING,
SENDER_BUSINESS_SYSTEM_ID TYPE STRING,
RECIPIENT_BUSINESS_SYSTEM_ID TYPE STRING,
BO TYPE STRING,
IV_APPLNR_CD TYPE STRING,
IV_OTHCHGREASON_TT TYPE STRING,
IT_EXTENSIONIN TYPE STRING,
IT_ADD_ASFUND_FM TYPE STRING,
IT_ADD_ASFUND TYPE STRING,
IT_ADD_BNFCRY_FM TYPE STRING,
IT_ADD_BNFCRY TYPE STRING,
IT_ADD_BNF_FM TYPE STRING,
IT_ADD_BNF TYPE STRING,
IT_ADD_CLAUSE_FM TYPE STRING,
IT_ADD_CLAUSE TYPE STRING,
IT_ADD_COVCPCO_FM TYPE STRING,
IT_ADD_COVCPCO TYPE STRING,
IT_ADD_COVPAC_FM TYPE STRING,
IT_ADD_COVPAC TYPE STRING,
IT_ADD_COV_FM TYPE STRING,
IT_ADD_COV TYPE STRING,
IT_ADD_CRDITOR_FM TYPE STRING,
IT_ADD_CRDITOR TYPE STRING,
IT_ADD_DEDCTBL_FM TYPE STRING,
IT_ADD_DEDCTBL TYPE STRING,
IT_ADD_DEDSRCL_FM TYPE STRING,
IT_ADD_DEDSRCL TYPE STRING,
IT_ADD_DIACODE_FM TYPE STRING,
IT_ADD_DIACODE TYPE STRING,
IT_ADD_EXREF_FM TYPE STRING,
IT_ADD_EXREF TYPE STRING,
IT_ADD_EXTPCL_FM TYPE STRING,
IT_ADD_EXTPCL TYPE STRING,
IT_ADD_EXTPOL_FM TYPE STRING,
IT_ADD_EXTPOL TYPE STRING,
IT_ADD_INFRD_FM TYPE STRING,
IT_ADD_INFRD TYPE STRING,
IT_ADD_LIMIT_FM TYPE STRING,
IT_ADD_LIMIT TYPE STRING,
IT_ADD_PREM_FM TYPE STRING,
IT_ADD_PREM TYPE STRING,
IT_ADD_REPVAL_FM TYPE STRING,
IT_ADD_REPVAL TYPE STRING,
IT_ADD_SBADR_FM TYPE STRING,
IT_ADD_SBADR TYPE STRING,
IT_ADD_SUBJCT_FM TYPE STRING,
IT_ADD_SUBJCT TYPE STRING,
IT_ADD_SUPDC_FM TYPE STRING,
IT_ADD_SUPDC TYPE STRING,
CHANGESTATE_ID TYPE STRING,
EXTENSIONIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-MESSAGE_HEADER sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CONTENT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-UUID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CONTENT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-REFERENCE_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CONTENT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-REFERENCE_UUID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SCHEME_AGENCY_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CONTENT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CREATION_DATE_TIME sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-SENDER_BUSINESS_SYSTEM_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-RECIPIENT_BUSINESS_SYSTEM_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-BO sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IV_APPLNR_CD sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IV_OTHCHGREASON_TT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_EXTENSIONIN sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_ASFUND_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_ASFUND sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_BNFCRY_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_BNFCRY sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_BNF_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_BNF sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_CLAUSE_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_CLAUSE sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COVCPCO_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COVCPCO sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COVPAC_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COVPAC sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COV_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_COV sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_CRDITOR_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_CRDITOR sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DEDCTBL_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DEDCTBL sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DEDSRCL_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DEDSRCL sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DIACODE_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_DIACODE sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXREF_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXREF sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXTPCL_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXTPCL sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXTPOL_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_EXTPOL sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_INFRD_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_INFRD sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_LIMIT_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_LIMIT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_PREM_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_PREM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_REPVAL_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_REPVAL sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SBADR_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SBADR sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SUBJCT_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SUBJCT sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SUPDC_FM sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-IT_ADD_SUPDC sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-CHANGESTATE_ID sy-vline
WA_/PM0/PCRP_I_PCR_MNG_CVP_RQ_STR-EXTENSIONIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.