ABAP Select data from SAP table /PM0/ALT_BI_SSWITCH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ALT_BI_SSWITCH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ALT_BI_SSWITCH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ALT_BI_SSWITCH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ALT_BI_SSWITCH TYPE STANDARD TABLE OF /PM0/ALT_BI_SSWITCH,
      WA_/PM0/ALT_BI_SSWITCH TYPE /PM0/ALT_BI_SSWITCH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ALT_BI_SSWITCH> TYPE /PM0/ALT_BI_SSWITCH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ALT_BI_SSWITCH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ALT_BI_SSWITCH
  INTO TABLE IT_/PM0/ALT_BI_SSWITCH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ALT_BI_SSWITCH
*  INTO TABLE @DATA(IT_/PM0/ALT_BI_SSWITCH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ALT_BI_SSWITCH INDEX 1 INTO DATA(WA_/PM0/ALT_BI_SSWITCH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ALT_BI_SSWITCH ASSIGNING </PM0/ALT_BI_SSWITCH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ALT_BI_SSWITCH>-POLICY_ID = 1.
</PM0/ALT_BI_SSWITCH>-PPDPAC_ID = 1.
</PM0/ALT_BI_SSWITCH>-POLICYPRODUCT_ID = 1.
</PM0/ALT_BI_SSWITCH>-COVPAC_ID = 1.
</PM0/ALT_BI_SSWITCH>-COVERAGE_ID = 1.
ENDLOOP.

LOOP AT IT_/PM0/ALT_BI_SSWITCH INTO WA_/PM0/ALT_BI_SSWITCH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ALT_BI_SSWITCH-SSHEAD_ID, sy-vline,
WA_/PM0/ALT_BI_SSWITCH-SSWITCH_ID, sy-vline,
WA_/PM0/ALT_BI_SSWITCH-CLIENT, sy-vline,
WA_/PM0/ALT_BI_SSWITCH-MOD_TS, sy-vline,
WA_/PM0/ALT_BI_SSWITCH-VALID_FROM_DT, sy-vline,
WA_/PM0/ALT_BI_SSWITCH-ORDERNO_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ALT_BI_SSWITCH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ALT_BI_SSWITCH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ALT_BI_SSWITCH INTO WA_/PM0/ALT_BI_SSWITCH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SYSTEM_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ALT_BI_SSWITCH-SYSTEM_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ALT_BI_SSWITCH-SYSTEM_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PALETTEINT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ALT_BI_SSWITCH-PALETTEINT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ALT_BI_SSWITCH-PALETTEINT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARENT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ALT_BI_SSWITCH-PARENT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ALT_BI_SSWITCH-PARENT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ALT_BI_SSWITCH-PARTNER_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ALT_BI_SSWITCH-PARTNER_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ALT_BI_SSWITCH_STR,
POLICY_ID TYPE STRING,
PPDPAC_ID TYPE STRING,
POLICYPRODUCT_ID TYPE STRING,
COVPAC_ID TYPE STRING,
COVERAGE_ID TYPE STRING,
SSHEAD_ID TYPE STRING,
SSWITCH_ID TYPE STRING,
CLIENT TYPE STRING,
MOD_TS TYPE STRING,
VALID_FROM_DT TYPE STRING,
ORDERNO_ID TYPE STRING,
BALEFFECTIVE_DT TYPE STRING,
CANCEFFECTIVE_DT TYPE STRING,
SYSTEM_ID TYPE STRING,
JOURNALNO_ID TYPE STRING,
DEL_FG TYPE STRING,
DELTA_FG TYPE STRING,
PMDELTAMODE_FG TYPE STRING,
PMBIRUN_ID TYPE STRING,
BO_CD TYPE STRING,
LOBJOURNALNO_ID TYPE STRING,
RELEASED_DT TYPE STRING,
SOURCEFUND_ID TYPE STRING,
TARGETFUND_ID TYPE STRING,
SOURCETARGET_CD TYPE STRING,
SOURCE_VL TYPE STRING,
SWITCH_TP TYPE STRING,
FUNDSHARES_VL TYPE STRING,
PM_ID TYPE STRING,
CURRENCY_ID TYPE STRING,
PALETTEINT_ID TYPE STRING,
AMOUNTASS_AM TYPE STRING,
PERCENTASS_VL TYPE STRING,
SHAREASS_VL TYPE STRING,
AMOUNTRES_AM TYPE STRING,
PERCENTRES_VL TYPE STRING,
DISTPRIM_CD TYPE STRING,
PARENT_ID TYPE STRING,
TOTALSHIFT_FG TYPE STRING,
SWITCHMIN_VL TYPE STRING,
SWITCH_UT TYPE STRING,
MGMTFEE_VL TYPE STRING,
ISUANCFE_VL TYPE STRING,
COLLKIND_CD TYPE STRING,
CHARGETYPEMAN_CD TYPE STRING,
CHARGESCHEMAN_CD TYPE STRING,
PARTNER_ID TYPE STRING,
CURRENTSHARES_VL TYPE STRING,
CURRENTPRICE_VL TYPE STRING,
CURRENTVALUE_VL TYPE STRING,
PRICE_DT TYPE STRING,
VALUEREL_VL TYPE STRING,
CUSTOMER_PL_CI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ALT_BI_SSWITCH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-POLICY_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PPDPAC_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-POLICYPRODUCT_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-COVPAC_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-COVERAGE_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SSHEAD_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SSWITCH_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CLIENT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-MOD_TS sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-VALID_FROM_DT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-ORDERNO_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-BALEFFECTIVE_DT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CANCEFFECTIVE_DT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SYSTEM_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-JOURNALNO_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-DEL_FG sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-DELTA_FG sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PMDELTAMODE_FG sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PMBIRUN_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-BO_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-LOBJOURNALNO_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-RELEASED_DT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SOURCEFUND_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-TARGETFUND_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SOURCETARGET_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SOURCE_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SWITCH_TP sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-FUNDSHARES_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PM_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CURRENCY_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PALETTEINT_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-AMOUNTASS_AM sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PERCENTASS_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SHAREASS_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-AMOUNTRES_AM sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PERCENTRES_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-DISTPRIM_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PARENT_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-TOTALSHIFT_FG sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SWITCHMIN_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-SWITCH_UT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-MGMTFEE_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-ISUANCFE_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-COLLKIND_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CHARGETYPEMAN_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CHARGESCHEMAN_CD sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PARTNER_ID sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CURRENTSHARES_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CURRENTPRICE_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CURRENTVALUE_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-PRICE_DT sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-VALUEREL_VL sy-vline
WA_/PM0/ALT_BI_SSWITCH_STR-CUSTOMER_PL_CI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.