ABAP Select data from SAP table /PM0/ABR_RANGE_DEDCTBL_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABR_RANGE_DEDCTBL_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABR_RANGE_DEDCTBL_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ABR_RANGE_DEDCTBL_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ABR_RANGE_DEDCTBL_S TYPE STANDARD TABLE OF /PM0/ABR_RANGE_DEDCTBL_S,
      WA_/PM0/ABR_RANGE_DEDCTBL_S TYPE /PM0/ABR_RANGE_DEDCTBL_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ABR_RANGE_DEDCTBL_S> TYPE /PM0/ABR_RANGE_DEDCTBL_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ABR_RANGE_DEDCTBL_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ABR_RANGE_DEDCTBL_S
  INTO TABLE IT_/PM0/ABR_RANGE_DEDCTBL_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ABR_RANGE_DEDCTBL_S
*  INTO TABLE @DATA(IT_/PM0/ABR_RANGE_DEDCTBL_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ABR_RANGE_DEDCTBL_S INDEX 1 INTO DATA(WA_/PM0/ABR_RANGE_DEDCTBL_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ABR_RANGE_DEDCTBL_S ASSIGNING </PM0/ABR_RANGE_DEDCTBL_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABR_RANGE_DEDCTBL_S>-/PM0/ABDADEDCTBL_OID = 1.
</PM0/ABR_RANGE_DEDCTBL_S>-DEDUCTIBLE_CD = 1.
</PM0/ABR_RANGE_DEDCTBL_S>-DEDCTBL_AM = 1.
</PM0/ABR_RANGE_DEDCTBL_S>-DEDCTBL_VL = 1.
</PM0/ABR_RANGE_DEDCTBL_S>-DEDCTBLMIN_AM = 1.
ENDLOOP.

LOOP AT IT_/PM0/ABR_RANGE_DEDCTBL_S INTO WA_/PM0/ABR_RANGE_DEDCTBL_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ABR_RANGE_DEDCTBL_S-DEDCTBLMAX_AM, sy-vline,
WA_/PM0/ABR_RANGE_DEDCTBL_S-DDTBEGIN_DT, sy-vline,
WA_/PM0/ABR_RANGE_DEDCTBL_S-DDTMOD_FG, sy-vline,
WA_/PM0/ABR_RANGE_DEDCTBL_S-DDTEND_DT, sy-vline,
WA_/PM0/ABR_RANGE_DEDCTBL_S-REFERENCE_ID, sy-vline,
WA_/PM0/ABR_RANGE_DEDCTBL_S-DEDUCTIBLETYP_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABR_RANGE_DEDCTBL_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABR_RANGE_DEDCTBL_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABR_RANGE_DEDCTBL_S INTO WA_/PM0/ABR_RANGE_DEDCTBL_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABR_RANGE_DEDCTBL_S_STR,
/PM0/ABDADEDCTBL_OID TYPE STRING,
DEDUCTIBLE_CD TYPE STRING,
DEDCTBL_AM TYPE STRING,
DEDCTBL_VL TYPE STRING,
DEDCTBLMIN_AM TYPE STRING,
DEDCTBLMAX_AM TYPE STRING,
DDTBEGIN_DT TYPE STRING,
DDTMOD_FG TYPE STRING,
DDTEND_DT TYPE STRING,
REFERENCE_ID TYPE STRING,
DEDUCTIBLETYP_CD TYPE STRING,
SORTSEQUDEDCT_VL TYPE STRING,
LIMITTYPE_CD TYPE STRING,
PM_ID TYPE STRING,
CURRENCY_ID TYPE STRING,
APPLNR_CD TYPE STRING,
DEDCTBLKFT_TT TYPE STRING,
DEDCTBLFT_TT TYPE STRING,
CUSTOMER_PB_CI TYPE STRING,
/PM0/ABDADEDCTBL_CID TYPE STRING,
DEDCTBLTP_TT TYPE STRING,
DEDUCTIBLETYP_TT TYPE STRING,
DEDUCTIBLE_TT TYPE STRING,
FROMRISK_FG TYPE STRING,
PBSTYP_TT TYPE STRING,
REFERENCE_TT TYPE STRING,
CUSTOMER_TB_CI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABR_RANGE_DEDCTBL_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-/PM0/ABDADEDCTBL_OID sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDUCTIBLE_CD sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBL_AM sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBL_VL sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBLMIN_AM sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBLMAX_AM sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DDTBEGIN_DT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DDTMOD_FG sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DDTEND_DT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-REFERENCE_ID sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDUCTIBLETYP_CD sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-SORTSEQUDEDCT_VL sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-LIMITTYPE_CD sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-PM_ID sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-CURRENCY_ID sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-APPLNR_CD sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBLKFT_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBLFT_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-CUSTOMER_PB_CI sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-/PM0/ABDADEDCTBL_CID sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDCTBLTP_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDUCTIBLETYP_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-DEDUCTIBLE_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-FROMRISK_FG sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-PBSTYP_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-REFERENCE_TT sy-vline
WA_/PM0/ABR_RANGE_DEDCTBL_S_STR-CUSTOMER_TB_CI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.