ABAP Select data from SAP table /PLMPCV/S_SIN_BA_MT_01_E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMPCV/S_SIN_BA_MT_01_E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMPCV/S_SIN_BA_MT_01_E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMPCV/S_SIN_BA_MT_01_E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMPCV/S_SIN_BA_MT_01_E TYPE STANDARD TABLE OF /PLMPCV/S_SIN_BA_MT_01_E,
      WA_/PLMPCV/S_SIN_BA_MT_01_E TYPE /PLMPCV/S_SIN_BA_MT_01_E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMPCV/S_SIN_BA_MT_01_E> TYPE /PLMPCV/S_SIN_BA_MT_01_E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMPCV/S_SIN_BA_MT_01_E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMPCV/S_SIN_BA_MT_01_E
  INTO TABLE IT_/PLMPCV/S_SIN_BA_MT_01_E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMPCV/S_SIN_BA_MT_01_E
*  INTO TABLE @DATA(IT_/PLMPCV/S_SIN_BA_MT_01_E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMPCV/S_SIN_BA_MT_01_E INDEX 1 INTO DATA(WA_/PLMPCV/S_SIN_BA_MT_01_E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMPCV/S_SIN_BA_MT_01_E ASSIGNING </PLMPCV/S_SIN_BA_MT_01_E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMPCV/S_SIN_BA_MT_01_E>-MATERIAL = 1.
</PLMPCV/S_SIN_BA_MT_01_E>-MATL_DESC = 1.
</PLMPCV/S_SIN_BA_MT_01_E>-MATL_TYPE = 1.
</PLMPCV/S_SIN_BA_MT_01_E>-IND_SECTOR = 1.
</PLMPCV/S_SIN_BA_MT_01_E>-DIVISION = 1.
ENDLOOP.

LOOP AT IT_/PLMPCV/S_SIN_BA_MT_01_E INTO WA_/PLMPCV/S_SIN_BA_MT_01_E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMPCV/S_SIN_BA_MT_01_E-MATL_GROUP, sy-vline,
WA_/PLMPCV/S_SIN_BA_MT_01_E-PROD_HIER, sy-vline,
WA_/PLMPCV/S_SIN_BA_MT_01_E-BASE_UOM, sy-vline,
WA_/PLMPCV/S_SIN_BA_MT_01_E-BASE_UOM_ISO, sy-vline,
WA_/PLMPCV/S_SIN_BA_MT_01_E-MATL_CAT, sy-vline,
WA_/PLMPCV/S_SIN_BA_MT_01_E-CREATED_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMPCV/S_SIN_BA_MT_01_E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMPCV/S_SIN_BA_MT_01_E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMPCV/S_SIN_BA_MT_01_E INTO WA_/PLMPCV/S_SIN_BA_MT_01_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMPCV/S_SIN_BA_MT_01_E-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMPCV/S_SIN_BA_MT_01_E-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMPCV/S_SIN_BA_MT_01_E_STR,
MATERIAL TYPE STRING,
MATL_DESC TYPE STRING,
MATL_TYPE TYPE STRING,
IND_SECTOR TYPE STRING,
DIVISION TYPE STRING,
MATL_GROUP TYPE STRING,
PROD_HIER TYPE STRING,
BASE_UOM TYPE STRING,
BASE_UOM_ISO TYPE STRING,
MATL_CAT TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
PUR_GROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMPCV/S_SIN_BA_MT_01_E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-MATERIAL sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-MATL_DESC sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-MATL_TYPE sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-IND_SECTOR sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-DIVISION sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-MATL_GROUP sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-PROD_HIER sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-BASE_UOM sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-BASE_UOM_ISO sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-MATL_CAT sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-CREATED_ON sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-CREATED_BY sy-vline
WA_/PLMPCV/S_SIN_BA_MT_01_E_STR-PUR_GROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.