ABAP Select data from SAP table /PLMI/S_RCA_EXPL_LOG_INT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMI/S_RCA_EXPL_LOG_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMI/S_RCA_EXPL_LOG_INT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PLMI/S_RCA_EXPL_LOG_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PLMI/S_RCA_EXPL_LOG_INT TYPE STANDARD TABLE OF /PLMI/S_RCA_EXPL_LOG_INT, WA_/PLMI/S_RCA_EXPL_LOG_INT TYPE /PLMI/S_RCA_EXPL_LOG_INT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PLMI/S_RCA_EXPL_LOG_INT> TYPE /PLMI/S_RCA_EXPL_LOG_INT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PLMI/S_RCA_EXPL_LOG_INT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PLMI/S_RCA_EXPL_LOG_INT INTO TABLE IT_/PLMI/S_RCA_EXPL_LOG_INT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PLMI/S_RCA_EXPL_LOG_INT * INTO TABLE @DATA(IT_/PLMI/S_RCA_EXPL_LOG_INT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PLMI/S_RCA_EXPL_LOG_INT INDEX 1 INTO DATA(WA_/PLMI/S_RCA_EXPL_LOG_INT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PLMI/S_RCA_EXPL_LOG_INT ASSIGNING </PLMI/S_RCA_EXPL_LOG_INT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMI/S_RCA_EXPL_LOG_INT>-CALC_ID = 1.
</PLMI/S_RCA_EXPL_LOG_INT>-ROW = 1.
</PLMI/S_RCA_EXPL_LOG_INT>-EXPL_LEVEL = 1.
</PLMI/S_RCA_EXPL_LOG_INT>-RCP_GUID = 1.
</PLMI/S_RCA_EXPL_LOG_INT>-SUBID = 1.
ENDLOOP. LOOP AT IT_/PLMI/S_RCA_EXPL_LOG_INT INTO WA_/PLMI/S_RCA_EXPL_LOG_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PLMI/S_RCA_EXPL_LOG_INT-ALT_NO, sy-vline,
WA_/PLMI/S_RCA_EXPL_LOG_INT-VERS_NO, sy-vline,
WA_/PLMI/S_RCA_EXPL_LOG_INT-SUBRECN, sy-vline,
WA_/PLMI/S_RCA_EXPL_LOG_INT-RCP_TYPE_ID, sy-vline,
WA_/PLMI/S_RCA_EXPL_LOG_INT-RCP_NAME, sy-vline,
WA_/PLMI/S_RCA_EXPL_LOG_INT-SUB_RCP_GUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMI/S_RCA_EXPL_LOG_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMI/S_RCA_EXPL_LOG_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMI/S_RCA_EXPL_LOG_INT INTO WA_/PLMI/S_RCA_EXPL_LOG_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit RCPNZ, internal->external for field ST_ID CALL FUNCTION 'CONVERSION_EXIT_RCPNZ_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-ST_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-ST_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit RCPNZ, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_RCPNZ_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-POSNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit RCPNZ, internal->external for field POSCOUNT CALL FUNCTION 'CONVERSION_EXIT_RCPNZ_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-POSCOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-POSCOUNT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit RCPNZ, internal->external for field STAGE_NO CALL FUNCTION 'CONVERSION_EXIT_RCPNZ_OUTPUT' EXPORTING input = WA_/PLMI/S_RCA_EXPL_LOG_INT-STAGE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_RCA_EXPL_LOG_INT-STAGE_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMI/S_RCA_EXPL_LOG_INT_STR,
CALC_ID TYPE STRING,
ROW TYPE STRING,
EXPL_LEVEL TYPE STRING,
RCP_GUID TYPE STRING,
SUBID TYPE STRING,
ALT_NO TYPE STRING,
VERS_NO TYPE STRING,
SUBRECN TYPE STRING,
RCP_TYPE_ID TYPE STRING,
RCP_NAME TYPE STRING,
SUB_RCP_GUID TYPE STRING,
SUB_EXT_KEY TYPE STRING,
SUBID TYPE STRING,
ALT_NO TYPE STRING,
VERS_NO TYPE STRING,
SUBRECN TYPE STRING,
SUB_RCP_NAME TYPE STRING,
FLG_PO TYPE STRING,
FLG_OS TYPE STRING,
FLG_SO TYPE STRING,
FLG_REWORK TYPE STRING,
FLG_UNUSED TYPE STRING,
FLG_EXPL_STOP TYPE STRING,
ITEM_GUID TYPE STRING,
STREAM_ID TYPE STRING,
ST_ID TYPE STRING,
POSNR TYPE STRING,
POSCOUNT TYPE STRING,
ITEM_SUBRECN TYPE STRING,
SUBSTANCE TYPE STRING,
MATERIAL TYPE STRING,
ITEM_TYPE TYPE STRING,
COMP_TYPE TYPE STRING,
MASSABSFLOAT TYPE STRING,
QUANTFLOAT TYPE STRING,
UOM TYPE STRING,
STAGE_NO TYPE STRING,
FLG_STD_EXPL TYPE STRING,
PARENT_ITEM_GUID TYPE STRING,
RULE_IND TYPE STRING,
MESSAGE_TABLE TYPE STRING,
SEVERITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMI/S_RCA_EXPL_LOG_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-CALC_ID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ROW sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-EXPL_LEVEL sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-RCP_GUID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUBID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ALT_NO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-VERS_NO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUBRECN sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-RCP_TYPE_ID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-RCP_NAME sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUB_RCP_GUID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUB_EXT_KEY sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUBID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ALT_NO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-VERS_NO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUBRECN sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUB_RCP_NAME sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_PO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_OS sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_SO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_REWORK sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_UNUSED sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_EXPL_STOP sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ITEM_GUID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-STREAM_ID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ST_ID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-POSNR sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-POSCOUNT sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ITEM_SUBRECN sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SUBSTANCE sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-MATERIAL sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-ITEM_TYPE sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-COMP_TYPE sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-MASSABSFLOAT sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-QUANTFLOAT sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-UOM sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-STAGE_NO sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-FLG_STD_EXPL sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-PARENT_ITEM_GUID sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-RULE_IND sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-MESSAGE_TABLE sy-vline
WA_/PLMI/S_RCA_EXPL_LOG_INT_STR-SEVERITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.