ABAP Select data from SAP table /PLMB/S_SPC_FES_STAT_CONF_SP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_SPC_FES_STAT_CONF_SP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_SPC_FES_STAT_CONF_SP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_SPC_FES_STAT_CONF_SP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_SPC_FES_STAT_CONF_SP TYPE STANDARD TABLE OF /PLMB/S_SPC_FES_STAT_CONF_SP,
      WA_/PLMB/S_SPC_FES_STAT_CONF_SP TYPE /PLMB/S_SPC_FES_STAT_CONF_SP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_SPC_FES_STAT_CONF_SP> TYPE /PLMB/S_SPC_FES_STAT_CONF_SP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_SPC_FES_STAT_CONF_SP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_SPC_FES_STAT_CONF_SP
  INTO TABLE IT_/PLMB/S_SPC_FES_STAT_CONF_SP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_SPC_FES_STAT_CONF_SP
*  INTO TABLE @DATA(IT_/PLMB/S_SPC_FES_STAT_CONF_SP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_SPC_FES_STAT_CONF_SP INDEX 1 INTO DATA(WA_/PLMB/S_SPC_FES_STAT_CONF_SP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_SPC_FES_STAT_CONF_SP ASSIGNING </PLMB/S_SPC_FES_STAT_CONF_SP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_SPC_FES_STAT_CONF_SP>-ESTCAT = 1.
</PLMB/S_SPC_FES_STAT_CONF_SP>-SPC_HDR_ID = 1.
</PLMB/S_SPC_FES_STAT_CONF_SP>-MANDT = 1.
</PLMB/S_SPC_FES_STAT_CONF_SP>-RECN = 1.
</PLMB/S_SPC_FES_STAT_CONF_SP>-ACTN = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_SPC_FES_STAT_CONF_SP INTO WA_/PLMB/S_SPC_FES_STAT_CONF_SP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT, sy-vline,
WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNPARENT, sy-vline,
WA_/PLMB/S_SPC_FES_STAT_CONF_SP-SPEC_VAL_INST, sy-vline,
WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ERRORMODE, sy-vline,
WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ERRORINFO, sy-vline,
WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ERRORCLASS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_SPC_FES_STAT_CONF_SP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_SPC_FES_STAT_CONF_SP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_SPC_FES_STAT_CONF_SP INTO WA_/PLMB/S_SPC_FES_STAT_CONF_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNPARENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNPARENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNPARENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNTVH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN_TPLH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN_TPLH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN_TPLH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNTVA_SRC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVA_SRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVA_SRC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNTVA_ORIG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVA_ORIG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNTVA_ORIG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT_ORIG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT_ORIG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECNROOT_ORIG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN_REFRH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN_REFRH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_SPC_FES_STAT_CONF_SP-RECN_REFRH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_SPC_FES_STAT_CONF_SP_STR,
ESTCAT TYPE STRING,
SPC_HDR_ID TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
RECNROOT TYPE STRING,
RECNPARENT TYPE STRING,
SPEC_VAL_INST TYPE STRING,
ERRORMODE TYPE STRING,
ERRORINFO TYPE STRING,
ERRORCLASS TYPE STRING,
ERRORPARAM TYPE STRING,
LOGLOCKMOD TYPE STRING,
EXTINFO TYPE STRING,
LINEMOD TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNTVH TYPE STRING,
ORD TYPE STRING,
COMPREL TYPE STRING,
FLG_INHSRC TYPE STRING,
FLG_INHOVR TYPE STRING,
FLG_INHEXCL TYPE STRING,
RECN_TPLH TYPE STRING,
RECNTVA_SRC TYPE STRING,
RECNTVA_ORIG TYPE STRING,
RECNROOT_ORIG TYPE STRING,
TPL_ORD TYPE STRING,
RECN_REFRH TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGE_NR_DESC TYPE STRING,
COMPDIMID TYPE STRING,
USAGE_STR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ESTCAT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-SPC_HDR_ID sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-MANDT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECN sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ACTN sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNROOT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNPARENT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-SPEC_VAL_INST sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ERRORMODE sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ERRORINFO sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ERRORCLASS sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ERRORPARAM sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-LOGLOCKMOD sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-EXTINFO sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-LINEMOD sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-MANDT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECN sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ACTN sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-VALFR sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-VALTO sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-AENNR sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-DELFLG sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-PARKFLG sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-CRDAT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-CRNAM sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-UPDDAT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-UPDNAM sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-SRSID sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-OWNID sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNROOT sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNTVH sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-ORD sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-COMPREL sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-FLG_INHSRC sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-FLG_INHOVR sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-FLG_INHEXCL sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECN_TPLH sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNTVA_SRC sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNTVA_ORIG sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECNROOT_ORIG sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-TPL_ORD sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-RECN_REFRH sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-CREATED_BY sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-CHANGED_BY sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-CHANGE_NR_DESC sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-COMPDIMID sy-vline
WA_/PLMB/S_SPC_FES_STAT_CONF_SP_STR-USAGE_STR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.