ABAP Select data from SAP table /PF1/STR_INCOMING_SEL_PARALLEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PF1/STR_INCOMING_SEL_PARALLEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PF1/STR_INCOMING_SEL_PARALLEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PF1/STR_INCOMING_SEL_PARALLEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PF1/STR_INCOMING_SEL_PARALLEL TYPE STANDARD TABLE OF /PF1/STR_INCOMING_SEL_PARALLEL,
      WA_/PF1/STR_INCOMING_SEL_PARALLEL TYPE /PF1/STR_INCOMING_SEL_PARALLEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PF1/STR_INCOMING_SEL_PARALLEL> TYPE /PF1/STR_INCOMING_SEL_PARALLEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PF1/STR_INCOMING_SEL_PARALLEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PF1/STR_INCOMING_SEL_PARALLEL
  INTO TABLE IT_/PF1/STR_INCOMING_SEL_PARALLEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PF1/STR_INCOMING_SEL_PARALLEL
*  INTO TABLE @DATA(IT_/PF1/STR_INCOMING_SEL_PARALLEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PF1/STR_INCOMING_SEL_PARALLEL INDEX 1 INTO DATA(WA_/PF1/STR_INCOMING_SEL_PARALLEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PF1/STR_INCOMING_SEL_PARALLEL ASSIGNING </PF1/STR_INCOMING_SEL_PARALLEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PF1/STR_INCOMING_SEL_PARALLEL>-RNG_CL_AREA = 1.
</PF1/STR_INCOMING_SEL_PARALLEL>-RNG_PO_DATE = 1.
</PF1/STR_INCOMING_SEL_PARALLEL>-RNG_PO_NO = 1.
</PF1/STR_INCOMING_SEL_PARALLEL>-RNG_PO_TYPE = 1.
</PF1/STR_INCOMING_SEL_PARALLEL>-RNG_PO_PRIORITY = 1.
ENDLOOP.

LOOP AT IT_/PF1/STR_INCOMING_SEL_PARALLEL INTO WA_/PF1/STR_INCOMING_SEL_PARALLEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_PO_SND_CNTRY, sy-vline,
WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_PO_SND_BNKKY, sy-vline,
WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_PO_SND_BIC, sy-vline,
WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_PO_EXT_REF, sy-vline,
WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_FORMAT, sy-vline,
WA_/PF1/STR_INCOMING_SEL_PARALLEL-RNG_PO_MEDIUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PF1/STR_INCOMING_SEL_PARALLEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PF1/STR_INCOMING_SEL_PARALLEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PF1/STR_INCOMING_SEL_PARALLEL INTO WA_/PF1/STR_INCOMING_SEL_PARALLEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PF1/STR_INCOMING_SEL_PARALLEL_STR,
RNG_CL_AREA TYPE STRING,
RNG_PO_DATE TYPE STRING,
RNG_PO_NO TYPE STRING,
RNG_PO_TYPE TYPE STRING,
RNG_PO_PRIORITY TYPE STRING,
RNG_PO_SND_CNTRY TYPE STRING,
RNG_PO_SND_BNKKY TYPE STRING,
RNG_PO_SND_BIC TYPE STRING,
RNG_PO_EXT_REF TYPE STRING,
RNG_FORMAT TYPE STRING,
RNG_PO_MEDIUM TYPE STRING,
RNG_PO_CHANNEL TYPE STRING,
RNG_PL_PROC_DATE TYPE STRING,
RNG_PL_PROC_TIM TYPE STRING,
RNG_PO_REL_STATUS TYPE STRING,
RNG_WORK_BASKET_ID TYPE STRING,
RNG_PO_SND_INT_CNTRY TYPE STRING,
RNG_PO_SND_INT_BNKKY TYPE STRING,
RNG_PO_SND_INT_BIC TYPE STRING,
RNG_PO_SND_INT_ACCT TYPE STRING,
RNG_PO_SND_INT_CURR TYPE STRING,
RNG_PO_SND_INT_IBAN TYPE STRING,
RNG_PO_PROC_DATE TYPE STRING,
RNG_PO_TECH_STAT TYPE STRING,
RNG_AMNT_SUM_ITEMS TYPE STRING,
RNG_REF_COLL_DATE TYPE STRING,
RNG_REF_COLL_NO TYPE STRING,
RNG_REF_COLL_SEQ_NO TYPE STRING,
RNG_OL_DATE TYPE STRING,
RNG_OL_NO TYPE STRING,
TAB_PO_KEY TYPE STRING,
TAB_COLL_KEY TYPE STRING,
TAB_OL_KEY TYPE STRING,
FLG_READ_PL_PROC_FUTURE TYPE STRING,
TAB_WHERE TYPE STRING,
RNG_TECHNICAL_PRIORITY TYPE STRING,
LOGONUSER TYPE STRING,
LOGONDATE TYPE STRING,
LOGONTIME TYPE STRING,
CLEARING_AREA TYPE STRING,
AR_SOURCE TYPE STRING,
READ_FROM_BUFFER TYPE STRING,
PACK_SIZE TYPE STRING,
POST_CANCEL TYPE STRING,
TA_OWNER TYPE STRING,
ONLINE_FLG TYPE STRING,
PO_NO_LOW TYPE STRING,
PO_NO_HIGH TYPE STRING,
TECH_LOG TYPE STRING,
MR_ID TYPE STRING,
PROCESS_TYPE TYPE STRING,
PACKNO TYPE STRING,
PACKNO2 TYPE STRING,
PROCSTEP TYPE STRING,
BALLOGHANDLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_CL_AREA sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_DATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_NO sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_TYPE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_PRIORITY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_CNTRY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_BNKKY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_BIC sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_EXT_REF sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_FORMAT sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_MEDIUM sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_CHANNEL sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PL_PROC_DATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PL_PROC_TIM sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_REL_STATUS sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_WORK_BASKET_ID sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_CNTRY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_BNKKY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_BIC sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_ACCT sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_CURR sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_SND_INT_IBAN sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_PROC_DATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_PO_TECH_STAT sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_AMNT_SUM_ITEMS sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_REF_COLL_DATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_REF_COLL_NO sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_REF_COLL_SEQ_NO sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_OL_DATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_OL_NO sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TAB_PO_KEY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TAB_COLL_KEY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TAB_OL_KEY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-FLG_READ_PL_PROC_FUTURE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TAB_WHERE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-RNG_TECHNICAL_PRIORITY sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-LOGONUSER sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-LOGONDATE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-LOGONTIME sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-CLEARING_AREA sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-AR_SOURCE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-READ_FROM_BUFFER sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PACK_SIZE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-POST_CANCEL sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TA_OWNER sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-ONLINE_FLG sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PO_NO_LOW sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PO_NO_HIGH sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-TECH_LOG sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-MR_ID sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PROCESS_TYPE sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PACKNO sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PACKNO2 sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-PROCSTEP sy-vline
WA_/PF1/STR_INCOMING_SEL_PARALLEL_STR-BALLOGHANDLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.