ABAP Select data from SAP table /ISDFPS/TS_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/TS_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/TS_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/TS_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/TS_DYNP TYPE STANDARD TABLE OF /ISDFPS/TS_DYNP,
      WA_/ISDFPS/TS_DYNP TYPE /ISDFPS/TS_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/TS_DYNP> TYPE /ISDFPS/TS_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/TS_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/TS_DYNP
  INTO TABLE IT_/ISDFPS/TS_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/TS_DYNP
*  INTO TABLE @DATA(IT_/ISDFPS/TS_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/TS_DYNP INDEX 1 INTO DATA(WA_/ISDFPS/TS_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/TS_DYNP ASSIGNING </ISDFPS/TS_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/TS_DYNP>-PNGUID = 1.
</ISDFPS/TS_DYNP>-PNAME = 1.
</ISDFPS/TS_DYNP>-PNTYPE = 1.
</ISDFPS/TS_DYNP>-PNTEXT = 1.
</ISDFPS/TS_DYNP>-PVGUID = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/TS_DYNP INTO WA_/ISDFPS/TS_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/TS_DYNP-PVNAME, sy-vline,
WA_/ISDFPS/TS_DYNP-MARK, sy-vline,
WA_/ISDFPS/TS_DYNP-MATNR, sy-vline,
WA_/ISDFPS/TS_DYNP-MAKTX, sy-vline,
WA_/ISDFPS/TS_DYNP-MANDT, sy-vline,
WA_/ISDFPS/TS_DYNP-PRGUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/TS_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/TS_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/TS_DYNP INTO WA_/ISDFPS/TS_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/TS_DYNP-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/TS_DYNP-PVNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ISDFPS/TS_DYNP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/TS_DYNP-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/TS_DYNP-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/TS_DYNP-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/TS_DYNP_STR,
PNGUID TYPE STRING,
PNAME TYPE STRING,
PNTYPE TYPE STRING,
PNTEXT TYPE STRING,
PVGUID TYPE STRING,
PVNAME TYPE STRING,
MARK TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
MANDT TYPE STRING,
PRGUID TYPE STRING,
OTYPE1 TYPE STRING,
GUID1 TYPE STRING,
APPLOBJ_TYPE1 TYPE STRING,
OTYPE2 TYPE STRING,
GUID2 TYPE STRING,
APPLOBJ_TYPE2 TYPE STRING,
PRTYPE TYPE STRING,
APPLREL_TYPE TYPE STRING,
HISTFLG TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
TIMSTMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/TS_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/TS_DYNP_STR-PNGUID sy-vline
WA_/ISDFPS/TS_DYNP_STR-PNAME sy-vline
WA_/ISDFPS/TS_DYNP_STR-PNTYPE sy-vline
WA_/ISDFPS/TS_DYNP_STR-PNTEXT sy-vline
WA_/ISDFPS/TS_DYNP_STR-PVGUID sy-vline
WA_/ISDFPS/TS_DYNP_STR-PVNAME sy-vline
WA_/ISDFPS/TS_DYNP_STR-MARK sy-vline
WA_/ISDFPS/TS_DYNP_STR-MATNR sy-vline
WA_/ISDFPS/TS_DYNP_STR-MAKTX sy-vline
WA_/ISDFPS/TS_DYNP_STR-MANDT sy-vline
WA_/ISDFPS/TS_DYNP_STR-PRGUID sy-vline
WA_/ISDFPS/TS_DYNP_STR-OTYPE1 sy-vline
WA_/ISDFPS/TS_DYNP_STR-GUID1 sy-vline
WA_/ISDFPS/TS_DYNP_STR-APPLOBJ_TYPE1 sy-vline
WA_/ISDFPS/TS_DYNP_STR-OTYPE2 sy-vline
WA_/ISDFPS/TS_DYNP_STR-GUID2 sy-vline
WA_/ISDFPS/TS_DYNP_STR-APPLOBJ_TYPE2 sy-vline
WA_/ISDFPS/TS_DYNP_STR-PRTYPE sy-vline
WA_/ISDFPS/TS_DYNP_STR-APPLREL_TYPE sy-vline
WA_/ISDFPS/TS_DYNP_STR-HISTFLG sy-vline
WA_/ISDFPS/TS_DYNP_STR-CREADAT sy-vline
WA_/ISDFPS/TS_DYNP_STR-CREABY sy-vline
WA_/ISDFPS/TS_DYNP_STR-CHNGDAT sy-vline
WA_/ISDFPS/TS_DYNP_STR-CHNGBY sy-vline
WA_/ISDFPS/TS_DYNP_STR-LOGSYS sy-vline
WA_/ISDFPS/TS_DYNP_STR-TIMSTMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.