ABAP Select data from SAP table /ISDFPS/ME_T351P into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/ME_T351P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/ME_T351P. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ISDFPS/ME_T351P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ISDFPS/ME_T351P TYPE STANDARD TABLE OF /ISDFPS/ME_T351P,
      WA_/ISDFPS/ME_T351P TYPE /ISDFPS/ME_T351P,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ISDFPS/ME_T351P> TYPE /ISDFPS/ME_T351P.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/ME_T351P.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ISDFPS/ME_T351P
  INTO TABLE IT_/ISDFPS/ME_T351P.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ISDFPS/ME_T351P
*  INTO TABLE @DATA(IT_/ISDFPS/ME_T351P2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ISDFPS/ME_T351P INDEX 1 INTO DATA(WA_/ISDFPS/ME_T351P2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ISDFPS/ME_T351P ASSIGNING </ISDFPS/ME_T351P>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/ME_T351P>-STRAT = 1.
</ISDFPS/ME_T351P>-ZAEHL = 1.
</ISDFPS/ME_T351P>-ZEIEH = 1.
</ISDFPS/ME_T351P>-LEIEH = 1.
</ISDFPS/ME_T351P>-ZYKZT = 1.
ENDLOOP.

LOOP AT IT_/ISDFPS/ME_T351P INTO WA_/ISDFPS/ME_T351P.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ISDFPS/ME_T351P-ZYKLS, sy-vline,
WA_/ISDFPS/ME_T351P-OFFZT, sy-vline,
WA_/ISDFPS/ME_T351P-OFFLS, sy-vline,
WA_/ISDFPS/ME_T351P-HIERA, sy-vline,
WA_/ISDFPS/ME_T351P-PUFFP, sy-vline,
WA_/ISDFPS/ME_T351P-PUFFN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/ME_T351P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/ME_T351P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/ME_T351P INTO WA_/ISDFPS/ME_T351P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field ZEIEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ISDFPS/ME_T351P-ZEIEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/ME_T351P-ZEIEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEIEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ISDFPS/ME_T351P-LEIEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/ME_T351P-LEIEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/ME_T351P_STR,
STRAT TYPE STRING,
ZAEHL TYPE STRING,
ZEIEH TYPE STRING,
LEIEH TYPE STRING,
ZYKZT TYPE STRING,
ZYKLS TYPE STRING,
OFFZT TYPE STRING,
OFFLS TYPE STRING,
HIERA TYPE STRING,
PUFFP TYPE STRING,
PUFFN TYPE STRING,
PERKN TYPE STRING,
EROEF TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/ME_T351P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/ME_T351P_STR-STRAT sy-vline
WA_/ISDFPS/ME_T351P_STR-ZAEHL sy-vline
WA_/ISDFPS/ME_T351P_STR-ZEIEH sy-vline
WA_/ISDFPS/ME_T351P_STR-LEIEH sy-vline
WA_/ISDFPS/ME_T351P_STR-ZYKZT sy-vline
WA_/ISDFPS/ME_T351P_STR-ZYKLS sy-vline
WA_/ISDFPS/ME_T351P_STR-OFFZT sy-vline
WA_/ISDFPS/ME_T351P_STR-OFFLS sy-vline
WA_/ISDFPS/ME_T351P_STR-HIERA sy-vline
WA_/ISDFPS/ME_T351P_STR-PUFFP sy-vline
WA_/ISDFPS/ME_T351P_STR-PUFFN sy-vline
WA_/ISDFPS/ME_T351P_STR-PERKN sy-vline
WA_/ISDFPS/ME_T351P_STR-EROEF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.