ABAP Select data from SAP table /BIC/CCTA0EC_CS_1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0EC_CS_1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0EC_CS_1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0EC_CS_1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0EC_CS_1 TYPE STANDARD TABLE OF /BIC/CCTA0EC_CS_1,
      WA_/BIC/CCTA0EC_CS_1 TYPE /BIC/CCTA0EC_CS_1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0EC_CS_1> TYPE /BIC/CCTA0EC_CS_1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0EC_CS_1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0EC_CS_1
  INTO TABLE IT_/BIC/CCTA0EC_CS_1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0EC_CS_1
*  INTO TABLE @DATA(IT_/BIC/CCTA0EC_CS_12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0EC_CS_1 INDEX 1 INTO DATA(WA_/BIC/CCTA0EC_CS_12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0EC_CS_1 ASSIGNING </BIC/CCTA0EC_CS_1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0EC_CS_1>-HSL = 1.
</BIC/CCTA0EC_CS_1>-KSL = 1.
</BIC/CCTA0EC_CS_1>-TSL = 1.
</BIC/CCTA0EC_CS_1>-MSL = 1.
</BIC/CCTA0EC_CS_1>-YTD_LC = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0EC_CS_1 INTO WA_/BIC/CCTA0EC_CS_1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0EC_CS_1-YTD_GC, sy-vline,
WA_/BIC/CCTA0EC_CS_1-YTD_TC, sy-vline,
WA_/BIC/CCTA0EC_CS_1-YTD_QTY, sy-vline,
WA_/BIC/CCTA0EC_CS_1-RLCUR, sy-vline,
WA_/BIC/CCTA0EC_CS_1-RGCUR, sy-vline,
WA_/BIC/CCTA0EC_CS_1-RTCUR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0EC_CS_1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0EC_CS_1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0EC_CS_1 INTO WA_/BIC/CCTA0EC_CS_1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0EC_CS_1_STR,
HSL TYPE STRING,
KSL TYPE STRING,
TSL TYPE STRING,
MSL TYPE STRING,
YTD_LC TYPE STRING,
YTD_GC TYPE STRING,
YTD_TC TYPE STRING,
YTD_QTY TYPE STRING,
RLCUR TYPE STRING,
RGCUR TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
RDIMEN TYPE STRING,
RVERS TYPE STRING,
FISCVARNT TYPE STRING,
FISCPER TYPE STRING,
RCONGR TYPE STRING,
RBUNIT TYPE STRING,
RITCLG TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
COICU TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
RBUPTR TYPE STRING,
PLEVL TYPE STRING,
DOCTY TYPE STRING,
HDATEFROM TYPE STRING,
HDATETO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0EC_CS_1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-HSL sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-KSL sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-TSL sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-MSL sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-YTD_LC sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-YTD_GC sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-YTD_TC sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-YTD_QTY sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RLCUR sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RGCUR sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RTCUR sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RUNIT sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RDIMEN sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RVERS sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-FISCVARNT sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-FISCPER sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RCONGR sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RBUNIT sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RITCLG sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RITEM sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-SITYP sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-SUBIT sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-COICU sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-YRACQ sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-PRACQ sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-RBUPTR sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-PLEVL sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-DOCTY sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-HDATEFROM sy-vline
WA_/BIC/CCTA0EC_CS_1_STR-HDATETO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.